Laserfiche WebLink
L <br /> In following with the good faith and intent of these standards it is <br /> recommended that the typical system to be installed on these four <br /> parcels and the designated remainder should consist of one-ninety foot <br /> leach line with a ten foot long by ten foot deep by two feet wide sump, <br /> located at the end of the leach line , for each bedroom of any future <br /> dwelling. With the minimum system being a two bedroom system. In <br /> addition it is recommended that each Parcel should hold in reserve <br /> 8,000 square feet of "Usable Disposal Area" , as defined by San Joaquin <br /> County Standards and Ordinance . <br /> LIMITATIONS <br /> The conclusions and recommendations of this report are based on <br /> information provided regarding the existing development and site <br /> conditions as they existed at the time of this study. It is assumed <br /> that the percolation results are representative of the subsurface <br /> conditions which exist on these parcels . <br /> It is my professional opinion that the findings included in this report <br /> are a reasonable assessment of the current subject parcels conditions , <br /> as tested. This opinion does not constitute a guarantee or warranty, <br /> either expressed or implied. <br /> Steven A. Mindt <br /> Registered Environmental Health Specialist <br /> California Registration Number 5999 <br />