Laserfiche WebLink
Soil Suitability Study (MS-92-188 , Parcel Nos . 1 and 2 ) 3 <br /> "Field Percolation Data Sheet " . <br /> These septic systems were installed between June 26 , 1970 and <br /> April 12 , 1989 . <br /> Existing Land Use: <br /> A small portion of the 20 acre parcel involved in this Soil <br /> Suitability Study is devoted to a homesite and barn situate in the <br /> southwest corner of Parcel No . 2 and is addressed at 7719 East <br /> Peltier Road, Acampo, California 95220 as shown on the attached <br /> "Parcel Map" . The rest of the land surrounding the homesite and <br /> barn to the north, east and south is devoted to agricultural use <br /> and is presently planted in alfalfa. <br /> Soil Profile Test : <br /> No water was encountered in excavating the Percolation and <br /> Soil Profile Test Holes to a maximum depth of ten ( 10) feet . See <br /> the attached "Field Percolation Data Sheet" and "Parcel Map" as <br /> well as the text of this report for the specific soil layer , <br /> character , and location details . The San Joaquin County Flood <br /> Control And Water Conservation Map entitled "Lines Of Equal Depth <br /> To Water Wells" dated Fall , 1990 shows the water to be in excess of <br /> 1.00 feet below the ground surface . <br /> Excavation to a maximum depth of ten ( 10) feet below the <br /> ground surface was performed for the Soil Profile investigation on <br /> Parcel No . 2 , at the location shown on the attached "Parcel Map" . <br /> The nature of the soil encountered in excavating to the 10-foot <br /> depth is noted on the "Soil Profile" on the "Field Percolation Data <br /> Sheet' as reddish-brown sandy loam throughout the ten-foot depth <br /> below the ground surface . For the first 6 1/2 feet below the ground <br /> surface was found to be rather loose but below 6 1/2 feet to 10 <br /> feet below the ground surface , the soil was noted to be dense and <br /> hard . <br /> Percolation Tests : <br /> Two ( 2 ) percolation test holes , one ( 1 ) on Parcel No . 1 and <br /> the other on Parcel No . 2 were excavated to about a 3-foot depth . <br /> The specific location of the two (2) percolation test holes are <br /> shown on the attached "Parcel Map" . <br /> All percolation tests conducted were performed in accordance <br /> with the percolation test procedures outlined in the "Manual Of <br /> Septic Tank Practice" published by the Department Of Health <br /> Education And Welfare and the requirements of the San Joaquin <br /> County Public Health Service, Environmental Health Division . <br /> .Tames W . Owens , 7719 East Peltier Road, Acampo , California 95220 <br />