Laserfiche WebLink
PA-1700032 (UP),S00011227 Page 2 of 3 <br /> 12165 S. Hwy 99, Manteca February 28, 2017 <br /> Continuation of Condition B: <br /> 3. The plans shall indicate the location of the new water lines that will be installed <br /> from the well to serve the new facility. <br /> 4. New water lines shall not be installed in the same trench and shall be at least ten <br /> feet horizontally from and one foot vertically above any parallel pip conveying: <br /> septage, sewage, or storm water pipe line conveyance. <br /> 5. If crossing a pipeline conveyance of septage, sewage, or storm water, the new <br /> water line shall be constructed no less than 45 degreess to and at least one foot <br /> above that pipeline. No connection joints shall be made in the water line within <br /> eight horizontal feet of the fluid pipeline. <br /> 6. The new water lines shall be disinfected and then tested by a California certified <br /> laboratory for chlorine residuals and Total coliforms bacteria. Laboratory results <br /> that report the new line to be absent for coliform bacterial and non-detect for <br /> chlorine shall be submitted to EHD prior to making a connection to the Public <br /> Water System. <br /> C. Submit to the Environmental Health Department revised site plans showing the <br /> maximum number of persons the sewage disposal system is being designed for. In <br /> addition, show on revised plans that the leach field area will be barricaded so it cannot <br /> be driven over, parked on, or used as a storage area. This leach field area must be <br /> used for that specific purpose only, and it cannot contain any underground utility lines <br /> (San Joaquin County Development Title, Section 9-1110.4(c)(5)). <br /> In addition, the revised site plan shall incorporate the 100% designed sewage disposal <br /> replacement area. <br /> D. Open, pump, and backfill the septic tank, seepage pit or excavation under permit and <br /> inspection by the Environmental Health Department (San Joaquin County Development <br /> Title, Section 9-1110.3 & 9-1110.4). <br /> E. Construction of an individual sewage disposal system(s) under permit and inspection by <br /> the Environmental Health Department is required at the time of development based on <br /> the Nitrate Loading Study findings (San Joaquin County Development Title, Section 9- <br /> 1110.3 & 9-1110.4). <br /> F. Any geotechnical drilling shall be conducted under permit and inspection by The <br /> Environmental Health Department (San Joaquin County Development Title, Section 9- <br /> 1115.3 and 9-1115.6). <br />