My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0012076
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
22420
>
2600 - Land Use Program
>
PA-1600194
>
SU0012076
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:59:06 PM
Creation date
9/8/2019 12:55:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012076
PE
2626
FACILITY_NAME
PA-1600194
STREET_NUMBER
22420
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220-
APN
01319005
ENTERED_DATE
11/27/2018 12:00:00 AM
SITE_LOCATION
22420 N HWY 99
RECEIVED_DATE
12/4/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\22420\PA-1600194\SU0012076\CDD OK.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
h. LANDSCAPING: Landscaping shall be provided and comply with the following: <br /> (1) This project will be required to comply with the Model Water Efficient Landscape Ordinance <br /> Requirement per California Code of Regulations, Title 23, Division 2, Chapter 2.7. <br /> (2) A minimum ten (10) foot wide landscaped strip, respecting the ultimate right-of-way width of E. <br /> Peltier Road, N. State Route 99 W. Frontage Road, and the State Route 99 southbound off-ramp <br /> shall be installed across the frontage of the project site. (Development Title Sections 9-1020.7 and <br /> 9-1020.9) <br /> (3) All areas not used for buildings, parking, driveways, walkways, approved outdoor storage areas, <br /> or other permanent facilities shall be landscaped. (Development Title Section 9-1020.8[a]) <br /> (4) Areas of the property which are not part of the project shall be barricaded from traffic and kept <br /> mowed and dust free. <br /> i. SCREENING: Screening shall be provided and comply with the following: <br /> (1) All storage materials and related activities, including storage areas for trash, shall be enclosed by <br /> a screen six (6) to seven (8) feet in height. Items stored within one hundred (100) feet of a <br /> dedicated street or residential zone shall not be stacked higher than two (2) feet above the <br /> adjacent screen. (Development Title Section 9-1022.4[e][2][A]) <br /> (2)All loose materials shall be contained in bins. (Development Title Section 9-505.6[d]) <br /> (3) Truck parts or inoperable trucks that are stored on the property of the truck terminal must be <br /> directly related to the operation of the truck terminal and shall be contained within a specified area <br /> that is fenced to provide an effective visual barrier. (Development Title Section 9-505.6[e]) <br /> (4) Any construction materials and all equipment used for the transfer and/or storage of construction <br /> materials shall be contained in a specified area that is fenced to provide an effective visual barrier. <br /> (Development Title Section 9-505.6[f]) <br /> j. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be included <br /> on the Site Plan. All portions of any sign shall be set back a minimum of five (5)feet from any future <br /> right-of-way line, including any corner cut-off(snipe). (Development Title Section 9-1710.2[g]) <br /> k. BUILDING CODE REQUIREMENTS: The following California Building Code(CBC)and San Joaquin <br /> County Ordinance requirements will be applicable to the proposed project. The following conditions <br /> shall be addressed prior to submittal of a building permit application to the Building Inspection Division: <br /> (1) A building permit for each separate structure or building is required. Submit plans, Specifications <br /> and supporting calculations, prepared by a Registered Design Professional(architect or engineer) <br /> for each structure or building, showing compliance with The 2016 California Building, Existing <br /> Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes as may be applicable. Plans <br /> for the different buildings or structures may be combined into a single set of construction <br /> documents. <br /> (2) A grading permit will be required for this project. Submit plans and grading calculations, including <br /> a statement of the estimated quantities of excavation and fill, prepared by a Registered Design <br /> Professional. The grading plan shall show the existing grade and finished grade in contour <br /> intervals of sufficient clarity to indicate the nature and extent of the work and show in detail that it <br /> complies with the requirements of the code. The plans shall show the existing grade on adjoining <br /> properties insufficient detail to identify how grade changes will conform to the requirements of the <br /> code. <br /> PA-1600194 (TE, UP) Conditions of Approval 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.