My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004226_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
24155
>
2600 - Land Use Program
>
PA-0300344
>
SU0004226_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:52:14 PM
Creation date
9/8/2019 12:56:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0004226
PE
2632
FACILITY_NAME
PA-0300344
STREET_NUMBER
24155
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
APN
00516011
ENTERED_DATE
5/14/2004 12:00:00 AM
SITE_LOCATION
24155 N HWY 99
RECEIVED_DATE
9/15/2003 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\24155\PA-0300344\SU0004226\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAINT JOAQUIN COUNTY "of <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> (; 304 E Weber Avenue 3rd Floor Stockton•CA 95202-2708 <br /> (209)468-3420•Fax:(209)464-0138• Web:www.co.san-joaquin.ca.us/ehd <br /> REQUIREMENTS CHECKLIST COMMENTS <br /> 24155 N. St Rte 99, Acam o, CA PA#: 03-444 <br /> E <br /> E LOCATION: p <br /> REPORT DATE: 9/24/2003 <br /> Section Comments <br /> 3.7 A traffic study was conducted and the projection was 120-150 vehicles in a peak hour(one hour).The <br /> report reflects 200 vehicles per 24 hours. Additional recommendations and further consideration will <br /> need to be addressed in an addendum. Based on several factors the average daily flow should be <br /> increased. This new calculation affects the requirement for changes to the proposed septic system <br /> to be installed including the addition of a 1200 gallon grease trap. Additional requirements and <br /> changes to the septic system may be warranted. <br /> 6.1 Percolation test appears to have been conducted within the proposed building parameter. No <br /> dimensions were provided in the report or on the site plan. <br /> 6.6 Percolation test was stamped but not signed. Resubmit form with signature. <br /> 6.7 Further recommendation will need to be addressed for the design of the septic system. Please contact <br /> Lisa Medina,Mike Huggins or Ray Borges for further discussion. <br /> EHD 2602-003 Page 3 of 3 <br /> 7/14/2003 <br />
The URL can be used to link to this page
Your browser does not support the video tag.