Soil Suitability Study - Parcel Map No. (MS-92-129- Cont . <br /> Parcel 1 had a percolation rate of 30 minutes <br /> per inch and Parcel 2 had a percolation rate <br /> of 60 minutes per inch. <br /> A water sample was taken from the existing well <br /> for nitrate . The test result was 9 . 8 mg/L. <br /> Recommendations : <br /> A combination of pits and leach lines are <br /> recommended for Parcel 1 . <br /> On Parcel 2 , damp sand was encountered at 13 <br /> feet . The percolation test hole was in the <br /> proximity of the existing pits , and that is <br /> probably why the layer of sand at 13 feet was <br /> damp. It is recommended that 8 , 000 Sq - <br /> Ft-minimum usable area be set aside for any possible <br /> future repairs or additions to the existing system. <br /> No special treatment is required of the well water . <br /> Engineer ' s Statement : <br /> Septic systems can be installed to the density <br /> proposed and it is not expected to impact <br /> groundwater nor cause other health hazards . <br /> Dwain C. Tosch <br /> Attachments : <br /> Detail Map <br /> Percolation Field Note Sheet <br /> Water Analysis Sheet <br /> N0. 74 rr3. <br /> E X P. Y......�.., ..� <br />