My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0008708 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
RAY
>
18375
>
2600 - Land Use Program
>
PA-1100053
>
SU0008708 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:38 AM
Creation date
9/9/2019 9:01:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0008708
PE
2622
FACILITY_NAME
PA-1100053
STREET_NUMBER
18375
Direction
N
STREET_NAME
RAY
STREET_TYPE
RD
City
LODI
APN
01116040
ENTERED_DATE
4/11/2011 12:00:00 AM
SITE_LOCATION
18375 N RAY RD
RECEIVED_DATE
4/11/2011 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\R\RAY\18375\PA-1100053\SU0008708\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Mr. Tasiopoulos and indicates a percolation rate for the hole based on <br /> the final water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is less than or equal to 60 minutes per inch (min/in) drop. A deep <br /> percolation test hole has a depth greater than 3.5 up to 25 feet; a satisfactory <br /> percolation rate for a deep test is 30 min/in or less. For the Site to utilize a standard <br /> septic system, one percolation test (either a shallow or deep test) must demonstrate a <br /> satisfactory percolation rate within the proposed septic system disposal field. <br /> Only a shallow test was performed for the proposed homesite parcel. Details and <br /> results of the percolation test are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Percolation Test Duration Comments <br /> Date Tested Test Rate (see notes) <br /> Depth (ft.) (minutes/inch) <br /> P1, - - <br /> 1 <br /> 12/14/11 3.20 11.9 i 4 hr. Satisfactoryperc. rate <br /> Shallow Test <br /> Note: A satisfactory percolation rate for a "shallow" test is less than or equal to 60 minutes per inch. A satisfactory <br /> percolation rate for a "deep"test is less than or equal to 30 minutes per inch. <br /> Discussion of Percolation Test Results <br /> The soils within the percolation test area have demonstrated a satisfactory percolation <br /> rate for the use of a standard septic system in accordance with the requirements of the C& <br /> San Joaquin County Environmental Health Department. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines and sumps or a filter bed should follow <br /> the San Joaquin County On-Site Wastewater Disposal Standards (2003) where <br /> applicable. <br /> LOGE 1112 Page 7 <br />