Laserfiche WebLink
PA-1900012 (SA) Referral, S00012439 Page 2 of 2 <br /> 1811 N. Report Ave. Stockton, CA 95205 July 26, 2019 <br /> 3. Reportable quantities of hazardous materials-reportable quantities are 55 gallons or more <br /> of liquids, 500 pounds for solids, or 200 cubic feet for compressed gases, with some <br /> exceptions. Carbon dioxide is a regulated substance and is required to be reported as a <br /> hazardous material if storing 1,200 cubic feet (137 pounds) or more onsite in San Joaquin <br /> County— Hazardous Materials Business Plan Program (HSC Sections 25508 & 25500 <br /> et sec.) <br /> 4. Any amount of hazardous material stored in an Underground Storage Tank — <br /> Underground Storage Tank Program (HSC Sections 25286 & 25280 et sec.) <br /> • If an underground storage tank (UST) system will be installed, a permit is required to <br /> be submitted to, and approved by, the San Joaquin County Environmental Health <br /> Department (EHD) before any UST installation work can begin. <br /> • Additionally, an EHD UST permit to operate is required once the approved UST system <br /> is installed. <br /> 5. Storage of at least 1 ,320 gallons of petroleum aboveground or any amount of petroleum <br /> stored below grade in a vault — Aboveground Petroleum Storage Program (HSC <br /> Sections 25270.6 & 25270 et sec.) <br /> • Spill Prevention, Countermeasures and Control (SPCC) Plan requirement <br /> 6. Threshold quantities of regulated substances stored onsite - California Accidental <br /> Release Prevention (CaIARP) Program (Title 19, Section 2735.4 & HSC Section 25531 <br /> et sec.) <br /> • Risk Management Plan requirement for covered processes <br />