Laserfiche WebLink
9-1015.9) <br /> 3. Each parking stall shall bean unobstructed rectangle, minimum nine (9)feet wide and twenty <br /> (20)feet long. (Development Title Section 9-1015.5[b]) <br /> e. ACCESS AND CIRCULATION: The following requirements apply and shall be shown on the Site <br /> Plan: <br /> 1. Access driveways shall have a width of no less than twenty-five (25) feet for two-way aisles <br /> and sixteen (16)feet for one-way aisles, except that in no case shall driveways designated as <br /> fire department access be less than twenty (20) feet wide. (Development Title Section 9- <br /> 1015.5[h][1]) <br /> f. LIGHTING: Lighting shall be provided and comply with the following: <br /> 1. If the parking area is to be used at night, parking lot and security lighting shall be installed. <br /> (Development Title Section 9-1015.5[g]) <br /> g. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be <br /> included on the Site Plan. All portions of any sign shall be set back a minimum of five(5)feet from <br /> any future right-of-way line, including any corner cut-off (snipe). (Development Title Section 9- <br /> 1710.2[g]) <br /> h. ANIMAL REGULATIONS: The following animal regulations apply and shall be provided: <br /> 1. All animal enclosures, including but not limited to pens, cages, and feed areas, shall be <br /> maintained free from litter, garbage, and excessive accumulation of manure, so as to <br /> discourage the proliferation of flies, other disease vectors, and offensive odors. Premises <br /> shall be maintained in a neat and sanitary manner. (Development Title Section 9-1045.4[b]) <br /> 2. Except for movement on and off the property,animals shall not be kept or maintained in coops, <br /> pens, corrals, or within barns or similar structures, closer than 40 feet from any rear or side <br /> property line. (Development Title Section 9-1045.3) <br /> i. BUILDING CODE REQUIREMENTS: The following California Building Code (CBC) and San <br /> Joaquin County Ordinance requirements will be applicable to the proposed project. The <br /> following conditions shall be addressed prior to submittal of a building permit application to the <br /> Building Inspection Division: <br /> 1. The Project Description to establish a commercial stable proposes to use all existing buildings. <br /> The approved use of the existing buildings was for agricultural use. The proposed change in <br /> use from agricultural to commercial use will constitute a change of occupancy. A change of <br /> occupancy will require a code analysis report and necessary plans prepared by an architect <br /> or engineer in accordance with the California Existing Building Code. The report and plans <br /> shall identify existing conditions, propose alterations necessary to bring the building in <br /> compliance with the current code and include the following: <br /> A. Description of proposed use <br /> B. Existing and proposed Occupancy Groups <br /> C. Type of construction <br /> D. Sprinklers(Yes or No) <br /> E. Number of stories <br /> F. Building height <br /> G. Allowable floor area <br /> H. Proposed floor area <br /> I. Occupant load based on the CBC for the new use <br /> PA-1900129 (UP)—Conditions of Approval 2 <br />