My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0000568 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SOUTHLAND
>
8908
>
2600 - Land Use Program
>
MS-91-94
>
SU0000568 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:27:48 AM
Creation date
9/9/2019 10:17:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0000568
PE
2622
FACILITY_NAME
MS-91-94
STREET_NUMBER
8908
Direction
E
STREET_NAME
SOUTHLAND
STREET_TYPE
RD
City
MANTECA
ENTERED_DATE
9/21/2001 12:00:00 AM
SITE_LOCATION
8908 E SOUTHLAND RD
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SOUTHLAND\8908\MS-91-94\SU0000568\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
File No. 20-3514-01 k%J KLEINFELDER <br /> September 11, 1991 <br /> passing the No. 200 Sieve of 40, a maximum Plasticity Index of 8, <br /> and a minimum R-Value of 40. Such imported fill should be <br /> compacted at a moisture content at or near optimum. We recommend <br /> that samples of any proposed imported fill soil be submitted to <br /> the soils engineer for approval prior to being taken to the site. <br /> Engineered Fill should be placed in horizontal layers a maximum of <br /> 8 inches in loose thickness and be compacted to a minimum of 90 <br /> percent of the maximum dry density as determined by the ASTM D- <br /> 1557 test procedure, at a moisture content near optimum. <br /> We recommend that structural and trench backfill be placed in the <br /> same manner as Engineered Fill . In our opinion, trench backfill <br /> y outside building areas may be jetted. However, if jetting is <br /> performed, sufficient time should be set aside to allow <br /> consolidation to occur. In addition, density tests should be <br /> taken to confirm the recommended compaction is achieved. <br /> In areas to receive asphaltic concrete, we recommend that the <br /> subgrade soils to a depth of at least 6 inches for existing soils <br /> and 12 inches for Engineered Fill be compacted at or near optimum <br /> moisture content, to a minimum of 95 percent of the referenced <br /> test procedure. <br /> Due to the reported standing surface water during heavy rains, we <br /> stress the importance of raising the building pads to above the <br /> anticipated high water level and of grading the pads to slope away <br /> from the buildings. In addition, especially on the south portion <br /> of the site, if floor slabs are used or there is any chance that <br /> standing water could develop beneath raised floors, we recommend <br /> ' that french drain systems be constructed to minimize the flow of <br /> water beneath the structures. The drains should extend to the <br /> silt soils encountered approximately 3-1/2 to 4 feet below <br /> existing ground surface. <br /> F. Pavement Sections <br /> We performed one R-Value test on a sample of the near-surface soil <br /> obtained from the approximate location shown on Plate A-1 of the <br /> appendix. The test results indicate an R-Value of 78 at an <br /> exudation pressure of 300 pounds per square inch. The detailed R- <br /> Value test result is presented on Plate A-8 of the appendix. The <br /> Caltrans method of design for flexible pavements permits the use <br /> of a maximum R-Value of 50 in design. However, the City of <br /> Manteca allows the use of a higher R-Value in design. Therefore, <br /> due to the high R-Value obtained, the city-allowed minimum <br /> pavement sections may apply. <br /> Copyright 1991 Kleinfelder, Inc. Page 7 of 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.