Laserfiche WebLink
MS 96-18 August 30, 1996 <br /> SOIL SUITABILITY STUDY <br /> for <br /> Ramon and Carol Ayon <br /> Property address: 24525 N. Sowles Road <br /> Acampo, CA 95220 <br /> f <br /> f PROJECT DESCRIPTION <br /> I <br /> This project proposes to divide a 10.4 acres parcel into two 5.2 acres parcels. <br /> TEST RESULTS <br /> I <br /> Parcel No. Test Hole No. Perc. Rate Min. Usable <br /> Disposal Area <br /> I <br />! 1. Pi 17 12,000 sq. ft. <br /> 2. P2 27 12,000 sq. ft. <br /> I <br /> RECOMMENDATIONS <br /> i <br />{ Parcels one and two ( land 2} i <br /> 12,000 sq. ft. of usable disposal area is recommended for these parcels. This is a <br /> i larger value than the test results indicate, however; field observations and other <br /> factors justify the higher value. <br /> EXISTING SEPTIC SYSTEM <br /> k <br /> The existing septic system consists of 3-40' leach lines and 3-42"x25' pits, installed <br /> in 1978. No permits for repairs or upgrades were found. The current owner stated <br /> that no problems have occurred. <br /> a <br /> k <br /> f <br />