My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0003863 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SOWLES
>
24720
>
2600 - Land Use Program
>
PA-0300678
>
SU0003863 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:30:10 AM
Creation date
9/9/2019 10:17:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0003863
PE
2622
FACILITY_NAME
PA-0300678
STREET_NUMBER
24720
Direction
N
STREET_NAME
SOWLES
STREET_TYPE
RD
City
ACAMPO
ENTERED_DATE
5/11/2004 12:00:00 AM
SITE_LOCATION
24720 N SOWLES RD
RECEIVED_DATE
2/3/2004 12:00:00 AM
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SOWLES\24720\PA-0300678\SU0003863\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
k'q KLEINFELDER <br /> Test Number Performed Depth, Feet Percolation Rate, Minutes/Inch <br /> P-1 3.40 13.6 <br /> 9.90 Failed <br /> P-2 3.30 15.63 <br /> 10.0 Failed <br /> P-3 3.40 Failed <br /> 12.30 22.73 - <br /> 7. CONCLUSIONS <br /> The results of percolation tests P-1 and P-2 in proposed Parcels 1 and 2 indicate that <br /> the near-surface soils (at a depth of about 3.4 and 3.30 feet, respectively) exhibit <br /> suitable percolation characteristics at the locations tested. A suitable soil condition for <br /> a test at this depth is defined as a stratum capable of percolating water at a rate of 60 <br /> minutes/inch or faster. Based on this result, a conventional septic tank/leach trench <br /> sewage disposal system designed per SJCEHD criteria should adequately serve the <br /> proposed residence. <br /> The results of percolation test P-3 located in the proposed Parcel 3 indicate that a <br /> suitable soil percolation stratum exists at a depth of about 12.30 feet below the <br /> existing ground surface at the location tested. A suitable soil condition for tests deeper <br /> than about 3'/2 feet is defined as a stratum capable of percolating water at a rate of 30 <br /> minutes/inch or faster. Based on the results of our testing, a conventional septic <br /> tank/leach trench sewage disposal system with s__eepa_ge pits designed per SjQEHD <br /> criteria should adequately serve the proposed residence. The seepage pits should <br /> extend into the soils that were encountered at the depth tested. <br /> These recommendations regarding the type of sewage disposal system appropriate for <br /> the proposed residences are for estimating purposes and are based on the specific <br /> locations tested. Once the locations of the proposed residences and associated <br /> sewage disposal systems are finalized, percolation tests should be run in the area of <br /> the proposed leach field areas. Results of the tests in the leach field areas should be <br /> used for final design of the proposed systems. <br /> 8. LIMITATIONS <br /> Kleinfelder has prepared this report in accordance with the generally accepted <br /> standards of care that exist in San Joaquin County at the time of writing. It should be <br /> recognized that definition and evaluation of geologic and chemical subsurface <br /> conditions are difficult. Judgments leading to conclusions and recommendations are <br /> generally made with an incomplete knowledge of the subsurface and/or historic <br /> conditions applicable to the site. The conclusions of this report are based on the <br /> 42270.G01/ST051322 October 21,2005 <br /> ©2005 Kleinfelder,Inc. Page 4 of 5 <br />