My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0003863 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SOWLES
>
24720
>
2600 - Land Use Program
>
PA-0300678
>
SU0003863 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:30:10 AM
Creation date
9/9/2019 10:17:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0003863
PE
2622
FACILITY_NAME
PA-0300678
STREET_NUMBER
24720
Direction
N
STREET_NAME
SOWLES
STREET_TYPE
RD
City
ACAMPO
ENTERED_DATE
5/11/2004 12:00:00 AM
SITE_LOCATION
24720 N SOWLES RD
RECEIVED_DATE
2/3/2004 12:00:00 AM
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SOWLES\24720\PA-0300678\SU0003863\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
kTJ KLEINFELDER <br /> Procedure #2). As specified, the last two 30-minute readings were recorded under the <br /> observation of a representative from the SJCEHD and were used to calculate the percolation <br /> rate in minutes per inch. The estimated percolation rates are summarized below. A copy of our <br /> field percolation test results signed by a representative. from SJCEHD is attached. Details of <br /> each test can be found on the percolation test sheet. <br /> During the percolation tests, groundwater rose in the deeper percolation test holes at locations <br /> P-2 and P-3. Therefore, the percolation tests in these holes could not be run. As stated in <br /> Section 3, published reports indicate that groundwater is at a depth of about 105 to 130 feet <br /> below the existing site grade in the project area. It is our opinion that the rising water was a <br /> perched groundwater condition likely caused by local irrigation. <br /> Test Number Performed Depth (feet) Percolation Rate (min./inch) <br /> 3.0 Did not percolate <br /> P-1 9.0 83.3 <br /> 3.2 25.0 <br /> P 2 8.0 Water elevation increasing in hole ' <br /> P-3 <br /> 3.0 125.0 <br /> 11.0 Water elevation increasing in hole <br /> On August 2, 2004, the same drill rig returned to the site and reinstalled two deep percolation <br /> tests at the locations of the P-1 and P-3. The holes were drilled and prepared before noon in <br /> accordance with SJCEHD criteria, as described above. The percolation tests were started at <br /> about 9:00 AM under sunny and warm weather on August 3, 2004, in accordance with accepted <br /> guidelines using clear potable water. The approximate depth of each test hole below existing <br /> site grade is shown on the following table. The holes did not exhibit sloughing or caving. At <br /> the time of testing no standing water from the presoaking remained in either test hole. A copy <br /> of our field percolation test results signed by a representative from SJCEHD is attached. <br /> Details of each test can be found on the percolation test sheet. <br /> Test Number Performed Depth (feet) Percolation Rate (min./inch) <br /> P-1 8.0 Did not percolate <br /> P-3 12.3 20.8 <br /> / 7. CONCLUSIONS <br /> The results of percolation test P-2 in proposed Parcel 2 indicates that the near surface soils (at a <br /> depth of about 3.2 feet) exhibit suitable percolation characteristics at the location tested. A <br /> suitable soil condition for a test at this depth is defined as a stratum capable of percolating <br /> water at a rate of 60 min/inch or faster. Based on this result, a conventional septic tank/leach <br /> trench sewage disposal system designed per SJCEHD criteria should adequately serve the <br /> proposed residence. <br /> 42270.G01/ST041383 October 15,2004 <br /> ©2004 Kleinfelder, Inc. Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.