Laserfiche WebLink
ENVIRONMENTAINW. . , <br /> Analytical Chemists <br /> June 21, 2016 Lab ID : STK1636839 <br /> Galloping Hills Winery Customer : 3-17803 <br /> Quality Control- Organic <br /> Constituent Method Date/ID Type Units Conc. QC Data DQO Note <br /> Organic <br /> 1,2-Dibromoethane(EDB) 504 06/08/16:206728SBL Blank ug/L ND <0.02 <br /> LCS ug/L 0.2548 94.4% 70-130 <br /> LCS ug/L 0.2522 104% 70-130 <br /> MS ug/L 0.2477 113% 70-130 <br /> (STK1636555-001) MSD ug/L 0.2461 120% 70-130 <br /> MSRPD ug/L 0.5776 5.1% <30 <br /> QMDL ug/L 0.02023 93.0% 60-140 <br /> 1,3-Dibromopropane 504 06/08/16:206728SBL Blank ug/L 0.5968 93.1% 70-130 <br /> LCS ug/L 0.5980 96.2% 70-130 <br /> LCS ug/L 0.5920 102% 70-130 <br /> MS ug/L 0.5813 99.2% 70-130 <br /> (STK1636555-001) MSD ug/L 0.5776 106% 70-130 <br /> MSRPD ug/L 0.5776 6.1% <_30 <br /> QMDL u /L 0.5978 91.5% 70-130 <br /> BCP 504 06/08/16:206728SBL Blank ug/L ND <0.01 <br /> LCS ug/L 0.2548 107% 70-130 <br /> LCS ug/L 0.2522 108% 70-130 <br /> MS ug/L 0.2477 101% 70-130 <br /> (STK1636555-001) MSD ug/L 0.2461 106% 70-130 <br /> MSRPD ug/L 0.5776 4.5% <30 <br /> QMDL ug/L 0.02023 1 131% 60-140 <br /> 13DBP 504.1 06/09/16:208115SBL CCV ug/L 9.975 94.6% 70-130 <br /> CCV ug/L 7.481 107% 70-130 <br /> CCV ug/L 9.975 95.7% 70-130 <br /> BCP 504.1 06/09/16:208115SBL CCV ug/L 5.000 102% 70-130 <br /> CCV ug/L 2.000 116% 70-130 <br /> CCV u /L 5.000 98.8% 70-130 <br /> DB 504.1 06/09/16:208115SBL CCV ug/L 5.000 101% 70-130 <br /> CCV ug/L 2.000 104% 70-130 <br /> CCV u /L 5.000 106% 70-130 <br /> Definition <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyted.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> MSRPD :MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> ND :Non-detect-Result was below the DQO listed for the analyte. <br /> DQO :Data Quality Objective-This is the criteria against which the quality control data is compared. <br /> Page 6 of 7 <br /> Corporate Offices&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory <br /> 853 Corporation Street 2500 Stagecoach Road 563 E.Undo Avenue 3442 Empresa Drive,Suite D 9415 W.Goshen Avenue <br /> Santa Paula,CA 93060 Stockton,CA 95215 Chico,CA 95926 San Luis Obispo,CA 93401 Visalia,CA 93291 <br /> TEL:(805)392-2000 TEL:(209)942-0182 TEL:(530)343-5818 TEL:(805)783-2940 TEL:(559)734-9473 <br /> Env FAX:(805)525-4172/Ag FAX:(805)392-2063 FAX:(209)942-0423 FAX:(530)343-3807 FAX:(805)783-2912 FAX:(559)734-8435 <br /> CA ELAP Certification No.1573 CA ELAP Certification No.1563 CA ELAP Certification No.2670 CA ELAP Certification No.2775 CA ELAP Certification No.2810 <br />