Laserfiche WebLink
r�The domestic well is proposed to be drilled northwest of the disposal area, which is downgradient, <br /> or possibly crossgradient to the leachfield. The separation distance between the well and the <br /> l�eachline�s will be approximately 140 ft, and 185 ft from the seepage pits. It will also be at the <br /> discretion of EHD to test the future well for the agrichemical DBCP and nitrate. <br /> It is important to recognize that all septic systems have a lifespan, which is dependant on several <br /> factors and is therefore difficult to determine. Leachline failure would primarily result from the <br /> advanced formation of a "biomat" or"clogging mat" on the wetted soil/effluent interface. This mat <br /> is composed mostly of aerobic and anaerobic bacteria and bacterial products consisting of a slime of <br /> polyuronides and polysaccharides. If the soil/effluent interface is well aerated, a variety of soil <br /> microfauna such as nematodes and protozoa may digest the clogging mat bacteria. <br /> Since the shallow subsurface soils on the property consist of cemented sands, silts, and some clays, <br /> anaerobic conditions may prevail over time which may accelerate biomat formation. As referenced, <br /> the deep septic system structures will manage the majority of effluent volume. Biomat formation <br /> will occur over time in these structures. <br /> In unsewered areas and/or areas that have been, or currently are under agricultural production, it is <br /> highly recommended that bottled water be used for drinking and cooking purposes. <br /> LIMITATIONS <br /> The findings, testing, opinions and conclusions of this report are based upon information from <br /> standard engineering and analytical test procedures, contemporary scientific literature and agency <br /> consultations. Information in this report is deemed reliable by the sources from where it was <br /> obtained. Results of the percolation testing should be assumed to only represent the subsurface <br /> conditions encountered in the specific location of testing as denoted on the preliminary Plot Plan, <br /> and not of the entire subject Parcel land area. <br /> This report is based upon current scientific knowledge to assess factors which are extremely <br /> variable and complex within the environment. San Joaquin County Environmental Health <br /> Department Sewage Standards have been employed for the purpose of preparing this study. <br /> Therefore, no guarantee or warranty is expressed or implied concerning any aspect of this <br /> investigation, the prevention of environmental impact, or related issues. <br /> I appreciate the opportunity to provide this service for you. If there should be any questions <br /> regarding the information contained within this report, please contact me. <br /> AAA 4t <br /> Respectfully submitted, �/o_ SHF <br /> (§ 7.1) CHES>FY CONSULTING <br /> 4k � No. 04675. � <br /> Don Chesney, R.E.A.- * Expires: G 3i•GG x <br /> Registered Environm ntal Assessor#4675 N„ �P <br /> Page- -01V CALI <br /> Chesney Consulting <br />