Laserfiche WebLink
Jul-17-02 04 : 02P P. 07 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> SAN JOAQUIN COUNTY <br /> Unit Swpervisors <br /> Donna K.Heron,R.E.H.S. Carl Bor man,R.E.H.S. <br /> Director 304 East Weber Avenue, Third Floor Borg <br /> man, <br /> Olsen,R.F.H.S. Stockton, California 95202-2708 Mike Huggins,R.E.H.S.,R.D.I. <br /> Douglas W,Wilson,R.E.H S. <br /> • i+.• Pro;gTelephone:Manager Tele hone: (209)468-3420 Margaret Lagorio,R.E.H.S. <br /> C Laurie A.CotrF. <br /> llr,R. .Ft.S. 7 Robert McClzltun,R.E.H.S. <br /> Program Manager Fax: (209) 464-0138 <br /> Mirk narccllvti.R.E.H.S. <br /> July 17, 2002 <br /> TO: San Joaquin County <br /> Community Development Department <br /> FROM: San Joaquin County <br /> Environmental health Department �Q <br /> CONTACT PERSON: Raymond Borges,Lead Senior R.E.H.S., R.D.l, lV, <br /> PHONE,NUMBER: (209)468-3284 <br /> 1ZE: PA-02-279 (SA), Attention: Rick Griffin <br /> 1001 North Stokes Avenue, Stockton <br /> The San Joaquin County Development Title Requirements listed below have been identified as <br /> pertinent to this project. Other requirements may also apply. These requirements cannot he <br /> modified <br /> A. Environmental Health Dcpartment requires a soil suitability/nitrate loading study <br /> incorporating proposed staff and customer use, indicating that the area is suitable for septic <br /> tank usage. This must be performed prior to issuance of building perntits(San Joaquin <br /> County Development Title, Section 9-1105.2(d)). A nitrate loading study is required, and a <br /> review fee of$445.00 must be paid at time of submittal to Enviroruncntal Health <br /> Department. <br /> The sewage disposal system shall comply with the on site sewage standards of San Joaquin <br /> County prior to approval. A percolation test that meets absorption rates of the manual of <br /> septic tank practice or E.P.A. Design Manual for onsite wastewater treatment and disposal <br /> system is required for each parcel. A permit fee of$89.00 per percolation hole is required. <br /> B. State on revised site Plans the maximum number of employees and customers the sewage <br /> disposal system is being designed for. In addition, show on revised plaits that the leach Feld <br /> area will be barricaded so it cannot be driven over, parked on, or used as a storage area. This <br /> leach field area must be used for that specific purpose only,and it cannot contain any <br /> underground utility lines(San Joaquin County Development Title, Section 9-1110,4(c)(5)). <br /> C. If hazardous waste is generated,applicant must obtain an EPA identification number and <br /> comply with applicable regulations. <br /> D. Open. pump,and backfill the septic tank, seepage pit or excavation under permit and <br /> inspection by the Environmental Health Department(San Joaquill County Development <br /> "ride, Section 9-1110.3 &9-1110.4)- <br />