Laserfiche WebLink
t � <br /> i <br /> (§ 1.0) INTRODUCTION <br /> FT�hisSuitability Study presents the results of my investigation concerning the soil <br /> characteristics and groundwater under the subject property referenced on the Title Page. It was <br /> completed to satisfy the requirements of the San Joaquin Environmental Health Department <br /> (EHD), as specified in their directive for Conditions of Approval, dated October 11, 2005. This <br /> document is found in Appendix A. <br /> Analysis and recommendations have been provided in this report based upon the environmental <br /> criteria encountered. My report is in compliance with the requirements for a Soil Suitability Study <br /> under Development Title, Section 9-1105.2 Item (d). <br /> Within the text of this Report, bolded Section (§) numbers are referenced at the beginning of an <br /> applicable sentence, paragraph or paragraphs, or Appendices that correspond with the EHD <br /> Requirements Checklist for a Soil Suitability Study. <br /> (§ 2.0) SUBJECT SITE AND STUDY AREA BACKGROUND INFORMATION <br /> (§ 1.1, 1.2, 3.7) The purpose of this project was a Lot Line Adjustment, completed by Mike <br /> Quartaroli, P.L.S. of Quartaroli and Associates. A new single family residential structure has been <br /> built on proposed Parcel 1 as depicted on the Tentative Lot Line Adjustment Map, found in <br /> Appendix A. A second unit dwelling cannot be built on this Parcel due to area constraints. The <br /> septic system to serve the residence has been partially installed, and the domestic well has been <br /> drilled. <br /> (§2.1) As stated in the EHD Conditions for Approval directive, this Soil Suitability Study was <br /> required"due to potential high groundwater and proximity to the rivers, EHD requires a Soil <br /> Suitability Study indicating that the area is suitable for septic tank usage." <br /> (§ 1.1 and 2.1) The subject property is 3 miles north of City of Tracy. Surrounding property use <br /> consists predominately of agricultural production land, The Old River and the Tracy Wildlife <br /> Association. Housing is extremely low density. Current zoning is AG-80. Municipal sewer will <br /> probably never serve this area, or at least not for several decades. (§ 4.2) Any of the above land <br /> use could create environmental concerns that may be discovered in the future. However, <br /> environmental concerns would primarily be from the over-application of nitrogen fertilizers. <br /> (§ 3.1,3.2, 3.3) As referenced, the septic system that will serve the new residence has been <br /> partially installed. Therefore, Sections §3.1, 3.2 and 3.3 are not applicable. The tight line from the <br /> house to the septic tank is in-place. The leachline trenches have been excavated and washed drain <br /> rock placed in the trenches. Perforated drain pipe has not been connected as of the date of the <br /> percolation testing. <br /> (§ 3.4,3.5,3.6) Microfiche records were examined at EHD for information on existing septic tank <br /> usage in the general area, along with septic permit history. The only permits found on Finck Road <br /> were an irrigation well permit and a domestic well permit. These are found.in Appendix C. <br /> Page -1- <br /> Chesney Consulting <br />