Laserfiche WebLink
SAN 10 A Q U I N Environmental Health Department <br /> I <br /> COUNTY Linda Turkatte, REHS, Director <br /> Greatness grows here. Kasey Foley,REHS,Assistant Director <br /> Sca�►,ud J PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> J JeffCarruesco, REHS, RDI <br /> J 0,0W)OL Willy Ng, REHS <br /> J Vp Muniappa Naidu, REHS <br /> Michael Kith, REHS <br /> August 14, 2019 47,9I 101 <br /> To: San Joaquin County Community Development Department <br /> Attention: Frank Girardi <br /> From: Steven Shih; (209) 468-9850 <br /> Lead Senior Registered Environmental Health Specialist <br /> RE: PA-1800207(SA), Referral, S00012488 <br /> 28850 South Tracy Boulevard, Tracy <br /> The following requirements have been identified as pertinent to this project. Other requirements <br /> may also apply. These requirements cannot be modified. <br /> A. A soil suitability/nitrate loading study incorporating proposed staff and customer use shall <br /> be submitted to the Environmental Health Department, indicating that the area is suitable <br /> for septic system usage. The studies must be approved by the Environmental Health <br /> Department prior to issuance of building permit(s). (San Joaquin County Development <br /> Title, Section 9-1105.2(d)). The fee will be based on the current schedule at the time of <br /> payment. <br /> The sewage disposal system shall comply with the onsite wastewater treatment systems <br /> standards of San Joaquin County prior to approval. A percolation test conducted in <br /> accordance with the E.P.A. Design Manual - Onsite Wastewater and Disposal Systems is <br /> required for each parcel. The fee will be based on the current schedule at the time of <br /> payment. <br /> B. Construction of an individual sewage disposal system(s) under permit and inspection by <br /> the Environmental Health Department is required at the time of development based on the <br /> Soil Suitability/ Nitrate Loading Study findings (San Joaquin County Development Title, <br /> Section 9-1110.3 & 9-1110.4). <br /> C. The existing private water wells shall be tested for the chemical Dibromochloropropane <br /> (DBCP) and nitrates with the results submitted to the Environmental Health Department <br /> prior to issuance of building permit(s). Samples are to be taken and analyzed by a State- <br /> approved laboratory (San Joaquin County Development Title, Section 9-1115.7). <br /> D. The well must be repaired under permit and inspection by the Environmental Health <br /> Department (San Joaquin County Development Title, Section 9-1115.4(e)) as follows: <br /> 1. Provide sample tap between the well head and the pressure tank. <br /> E. If floor drains are proposed, they must be plumbed through a sand/oil separator and <br /> discharged to an above ground system approved by the Environmental Health Department. <br /> A registered engineer must design this system. The material collected in the above ground <br /> holding system must be analyzed for hazardous constituents prior to disposal. <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />