Laserfiche WebLink
a _ <br /> E <br /> l } ❑ ani® ❑❑®❑®❑®0000❑ ❑ <br /> Drip Users shall comply with the following conditions/requirements when <br /> Application applying 1,3-D through drip application systems. This section applies to <br /> P Method 1nLine"I and TeloneT�' EC. <br /> Application Drip irrigation applications on soil surface or buried drip application shall use <br /> Tinning and an AF of 1.16,regardless of depth. <br /> Corresponding <br /> Application Application Time and Area <br /> Factor . Generally, applications are allowed statewide during the entire year. <br /> However, applications shall not occur in the San Joaquin Air Basin during <br /> Fil January and December of each calendar year. <br /> Calculating the The adjusted total pounds (ATP) for each application shall be calculated <br /> ATP of 1,3-D based on the following: <br /> When Applying <br /> By Drip 1. The total gallons (TG) of the pesticide formulation <br /> Application 2 The pounds per gallon (lbs./gal) for the pesticide formulation <br /> Systems 3. The percent by weight (XX%) of 1,3-D in the pesticide formulation, <br /> Fexpressed as a decimal (.XX) <br /> 4. The total pounds (TP) of 1,3-D <br /> S. The application factor (1.16 AF) <br /> FThe ATP for each application shall be calculated using the following formula: <br /> TG x lbs./gal x (.XX) x 1.16 AF <br /> F.' <br /> k e Convert 1,3-D percentage by weight (XX%)to a decimal, divide XX%by <br /> 100=.XX <br /> F • To find the TP, multiply, TG x lbs./gal x (.XX) =TP <br /> To find the ATP, multiply, TP x 1.16 AF=ATP <br /> Continued on nextpage <br /> �I <br /> E � � <br /> 1 i <br />