I. INTRODUCTION <br /> This report issues my findings regarding the Nitrate Loading Study, Soil Suitability Study and <br /> Wastewater Disposal Operational and Design Parameters for the proposed Ripon Church of Christ <br /> in Ripon, California. The Church is in the process of constructing a new Worship Center; <br /> consequently, these studies were required by the San Joaquin County Environmental Health <br /> Department(EHD) and comply with the San Joaquin County Development Title, specifically <br /> Section 9-1105.2(d). The Site Plan and associated civil engineering information have been <br /> produced by Hawkins &Associates Engineering of Modesto, California. <br /> Within the text of this Report, Bolded Section (§)numbers are referenced at the beginning of an <br /> applicable Paragraph or Paragraphs, or Appendices that correspond with the EHD Requirements <br /> Checklist. Section Numbers referenced as SSS§, are sections applicable for the Soil Suitability <br /> Study Requirements Checklist. Section Numbers referenced as NLS§, are sections applicable <br /> for the Nitrate Loading Study Requirements Checklist. Other portions of text may also apply to <br /> other sections of the Checklists. <br /> NLS§2.3. Since the property remains in the County, the City of Ripon sewer will not serve the <br /> future development. Therefore, the Church will operate with an on-site decentralized wastewater <br /> management system, commonly referred to as a septic system. It is my understanding that a new <br /> domestic well is to be drilled to serve the Church. <br /> SSS§ 12. The Church is located near the NWC of Jack Tone and West Ripon Roads. Currently, <br /> the Church property is vacant except for a residential structure that is to be the Pastor's residence, a <br /> sea container, and construction materials for the new Church. The total Parcel area for the Church <br /> site is 3.09 acres. <br /> The following paragraphs summarize the purpose and findings of these Studies to fulfill the <br /> requirements of the EHD. Wastewater system operational and design parameters are also <br /> presented within this document to facilitate the transfer of information to EHD: <br /> • An analysis was completed of the indigenous soils in the proposed effluent disposal area to <br /> determine the acceptance of the anticipated wastewater flows, along with an assessment of the <br /> characteristics of the soil with respect to nitrate impact. Discussions are presented on the <br /> operational parameters to achieve the two goals of proper wastewater management and nitrate <br /> loading mitigation. These two goals were accomplished by the referenced testing, physical/ <br /> chemical analyses, and operational parameters incorporated into the design of the wastewater <br /> disposal system. <br /> • It has been determined that the new primary filter bed system disposal area can be installed in the <br /> SEC of the property,as situated by Hawkins Engineering. The 100%reserve/replacement/ <br /> addition area is adjacent to the west of the primary field. <br /> • Although wastewater flow volumes emanating from the Church project are unknown,they have <br /> been formulated for this report using available and acceptable parameters. <br /> I <br />