r v <br /> UEC Document No.: R3579811 <br /> December 7, 1998 <br /> The soil existing along the north side of the South Parcel was observed to have the same physical <br /> characteristics as the soil along the south periphery of the North Parcel. In summary, the soil down to a <br /> depth of 5 feet below grade observed in two of the four holes dug, consisted of primarily loam, with a small <br /> sand component; no clayey films or strata were observed. The soils were observed to be uniform in color <br /> (medium brown) and texture. Soil Profile holes numbered 3 and 4 in Figure 3 contained a few stray roots <br /> between 2.0 and 3.0 feet below grade due to the close proximity of grape vines. No rock was observed in <br /> any of the four profile holes. Due to the recent rain in the subject site area, the uppermost 2.0-2.5 feet of <br /> soil had a higher moisture content then at deeper depths; no soil was observed to be in a saturated state. <br /> The two Soil Percolation tests were performed in strict adherence to the procedure set forth in Appendix A; <br /> as previously mentioned, the two Soil Percolation test holes were dug to a depth of 24 inches below grade <br /> with a backhoe, then advanced to a depth of 39 inches with a post hole digger. The average boring <br /> diameter for each of the two holes was 7.75 inches; the borings' walls were supported by 0.25" wire mesh <br /> in order to delay hole collapse. Two inches of fine gravel were put in place at the bottom of each of the <br /> borings. Rulers graduated in 0.25" intervals were establish within the borings along the borings' walls; <br /> the rulers were held in place with duct tape and nr ipp r to move throughout the tests. Both holes <br /> were presoaked with 14" of clear wat 4 rs r\tie the commencement of the Soil Percolation test <br /> period. In both holes, it was observed t® al the presoak water had percolated into the soil throughout <br /> the evening; there was no water observed in either hole the following morning. <br /> Soil Percolation test hole #4 appeared to be nearly identical in appearance to Soil Percolation test hole #3; <br /> however, the percolation test data collected from hole #4 became skewed due to silting. Two hours into <br /> the Soil Percolation test at hole#4, the sides and edges of the hole were observed to have collapsed inward. <br /> At the end of the test, the UEC staff measured over 2 inches of silt at the bottom of he hole. The effect of <br /> the silting is to reduce the percolation rates and give the appearance that the soil does not percolate as well <br /> as it actual does. If a septic system were to be installed in this area, the leach lines should contain granular <br /> annular seals to help prevent the leach holes from filling with silt. The calculated percolation rates for hole <br /> #4 are based on data collected from the next to last timed interval. During that 30 minute time period, the <br /> water level was observed to drop 0.13", resulting in a percolation rate of 0.0043 inches of water per minute <br /> or 230.8 minutes per inch of water. As previously noted, these rates are believed to be artificially low due <br /> to the silting of the Soil Percolation test hole. <br /> 3 <br />