My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0012431
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Z
>
ZUCKERMAN
>
1101
>
2600 - Land Use Program
>
PA-1900158
>
SU0012431
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:45 AM
Creation date
9/9/2019 11:17:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012431
PE
2664
FACILITY_NAME
PA-1900158
STREET_NUMBER
1101
Direction
N
STREET_NAME
ZUCKERMAN
STREET_TYPE
RD
City
STOCKTON
Zip
95219-
APN
12931012
ENTERED_DATE
7/16/2019 12:00:00 AM
SITE_LOCATION
1101 N ZUCKERMAN RD
RECEIVED_DATE
7/23/2019 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
TSok
Supplemental fields
FilePath
\MIGRATIONS\Z\ZUCKERMAN\1101\PA-1900158\SU0012431\APPL.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rick Griffin,Project Manager <br /> Page 2 <br /> August 6, 2019 <br /> An example would be where there is such a unique physical condition of the site that no other <br /> alternatives are possible. For example, a residential structure on a narrow lot with a setback <br /> requirement,where the structure must have an elevated lowest floor: in such a situation a <br /> variance may be issued to provide relief from the required elevation. However,the relief <br /> provided must be the minimum necessary(my emphasis)to provide relief and an elevated floor <br /> is still required. <br /> Variances may be issued for new construction and substantial improvements to be erected on a <br /> lot of one-half acre or less in size, in conformance with the conditions and technical findings that <br /> are outlined in your county's flood damage prevention ordinance(San Joaquin County Code 9- <br /> 484). As the lot size increases the rationale for the variance decreases and the requirements and <br /> justification for the variance become more restrictive. <br /> In this request,the structure is not residential,therefore elevation is not the only method of flood <br /> damage avoidance; structures can also be floodproofed. Additionally, the property is zoned AG- <br /> 80, with lot sizes of 80-acre minimum. Economic considerations are not a hardship. It would be <br /> difficult to argue that a variance for this application, without adhering to the minimum NFIP <br /> design criteria would be a prudent and safe way for development on the site. <br /> San Joaquin County participates in the Community Rating System(CRS)and is currently a Class <br /> 7 community. San Joaquin County residents enjoy a 15%discount on their flood insurance <br /> premiums precisely because the County has adopted building requirements and floodplain <br /> management practices which are more restrictive than the minimum federal standards. <br /> Entertaining this variance request runs counter to the nature,reason,and administration of the <br /> NFIP in general and the CRS program in particular. <br /> Therefore,this office's review and comment on variance application PA-1900158 (FVR) is that <br /> it should not be approved and the project should comply with the County's Flood Hazard <br /> ordinance. <br /> Please review the current effective Flood Insurance Rate Maps (F1RMs)for the County of San <br /> Joaquin (Community Number 060299), Maps revised October 20, 2016. <br /> A partial summary of NFIP floodplain management building requirements are as follows: As <br /> previously addressed in this letter, San Joaquin County has more restrictive standards than the <br /> minimum NFIP requirements. Elevation standards for lowest floor may be more restrictive. <br /> • All buildings constructed within a riverine floodplain, (i.e.,Flood Zones A, A0,AH,AE, <br /> and Al through A30 as delineated on the FIRM),must be elevated so that the lowest <br /> floor is at or above the Base Flood Elevation level in accordance with the effective Flood <br /> Insurance Rate Map. <br /> ww%vlema.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.