23535
>
1900 - Hazardous Materials Program
>
PR0520088
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2019 9:59:51 AM
Creation date
9/12/2019 9:53:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1900 - Hazardous Materials Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0520088
PE
1921
FACILITY_ID
FA0007174
FACILITY_NAME
SAN I PAK INC
STREET_NUMBER
23535
Direction
S
STREET_NAME
BIRD
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25010002
CURRENT_STATUS
01
SITE_LOCATION
23535 S BIRD RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 6)ACCIDENTAL RELEASE MEASURES <br /> Emergency Procedure <br /> Evacuate and isolate hazard area and keep unauthorized personnel away.Stay uphill and/or upstream.Ventilate closed spaces before <br /> entering. Do not touch or walk through spilled material. <br /> Recommended Equipment <br /> Wear liquid tight chemical protective clothing in combination with positive pressure self-contained breathing apparatus(SCBA).Breathing <br /> protection is required. <br /> Personal Precautions <br /> DO NOT breathe vapor or mist. <br /> DO NOT get on skin,eyes or clothing. <br /> Environmental Precautions <br /> Prevent further leakage or spillage if safe to do so. Prevent spilled material from entering sewers,storm drains,other unauthorized <br /> drainage systems and natural waterways by using sand,earth,or other appropriate barriers. <br /> Methods and Materials for Containment and Cleaning Up <br /> For small amounts:Absorb isocyanate with suitable absorbent material.Shovel into open container.Do not make container pressure tight. <br /> Move container to a well-ventilated area(outside).Spill area can be decontaminated with the following recommended decontamination <br /> solution:Mixture of 90%water,8%concentrated ammonia,2%detergent.Add at a 10 to 1 ratio.Allow to stand for at least 48 hours to <br /> allow escape of evolved carbon dioxide. <br /> For large amounts: If temporary control of isocyanate vapor is required,a blanket of protein foam or other suitable foam(available from <br /> most fire departments)may be placed over the spill.Transfer as much liquid as possible via pump or vacuum device into closed but not <br /> sealed containers for disposal. <br /> For residues:The following measures should be taken for final cleanup:Wash down spill area with decontamination solution.Allow <br /> solution to stand for at least 10 minutes. <br /> SECTION 7) HANDLING AND STORAGE <br /> General <br /> Wash hands after use. <br /> Do not get in eyes,on skin or on clothing. <br /> Do not breathe vapors or mists. <br /> Use good personal hygiene practices. <br /> Eating,drinking and smoking in work areas is prohibited. <br /> Remove contaminated clothing and protective equipment before entering eating areas. <br /> All containers must be properly labelled. <br /> Eyewash stations and showers should be available in areas where this material is used and stored <br /> Ventilation Requirements <br /> Use only with adequate ventilation to control air contaminants to their exposure limits. Report ventilation failures immediately. <br /> Storage Room Requirements <br /> Store in cool,dry,well-ventilated areas away from heat,direct sunlight and strong oxidizers.Keep containers securely sealed when not in <br /> use.Suitable materials for containers:Carbon steel(Iron), High density polyethylene(HDPE),Low density polyethylene(LDPE),Stainless <br /> steel 1.4301 (V2).Formation of CO2 and build-up of pressure possible.Outage of containers should be filled with dry inert gas at <br /> atmospheric pressure to avoid reaction with moisture.Empty containers retain residue and may be dangerous. <br /> Storage temperature:60-80°F.Protect against moisture. <br /> SECTION 8) EXPOSURE CONTROLS/PERSONAL PROTECTION <br /> Eye Protection <br /> Wear indirect-vent, impact and splash resistant goggles when working with liquids. If additional protection is needed for entire face,use in <br /> combination with a face shield. <br /> Skin Protection <br /> Use of gloves approved to relevant standards made from the following materials may provide suitable chemical protection: PVC, <br /> neoprene or nitrile rubber gloves.Suitability and durability of a glove is dependent on usage,e.g.frequency and duration of contact, <br /> KG 3607 ISOCYANATE www.ultimatelinings.com Page 4 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.