Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank ( UST) monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local <br /> agency regulating the USTs within 30 days of the date of the monitoring system certification . <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10180717 4/11 /19 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) Building # <br /> Fast & Easy Morada #60 (Stockton) <br /> Business Site Address City ZIP Code <br /> 10878 N Highway 99 Stockton 95212 <br /> IL UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> Confidence UST Services , Inc . ( 800 ) 339- 9930 <br /> Mailing Address <br /> 16250 Meacham Road , Bakersfield , CA 93314 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification) <br /> Timothy Capehart <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 804904 8414476 3/3/2020 <br /> Monitoring System Training and Certifications List all applicable certifications. Expiration Date <br /> Veeder root b47819 3/3/2020 <br /> III . RESULTS OF TESTING / SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> XX Monitoring System Set-up Alarm History Report <br /> Was any monitoring equipment replaced ? <br /> (If "Yes, " identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) Ex El El <br /> Was damage , debris , or liquid found inside any secondary containment systems? 0 X❑ ❑ <br /> (If "Yes, " describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer's specifications? N ❑ ❑ <br /> (If "No, " describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> Found 91 #1 sump sensor not in the lowest point. It was repositioned by the technician and is now at the lowest point. <br /> Found Diesel STP with FX- 1 V leak detector, replaced with correct leak detector FX- 1 DV, retest with pass <br /> Found Unleaded leak detector failing initial test. It was readjusted and retested with passing results . <br /> Found 91 #2 product piping had a plugged clamshell . It was removed 4/12/2019 by technician Timothy Capehart. <br /> APR 9- <br /> 3 <br /> S K <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CON DU d TI•iftfVOT1N 1.- <br /> I hereby certify that the equipment identified in this document was inspected/serviced in acco .4c . i I'fgrnia Code of <br /> Regulations , Title 23, Division 3, Chapter 16, Section 2638 and all information contained herein is true and a�c& rate ` Attached to <br /> this certification is information (e . g . , manufacturers' checklists , monitoring system set-up , alarm history report, etc .) necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate . <br /> UST Service Technician Signature <br /> CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, Y = Yes, N = No, NA = Not Applicable <br /> UNA07 www, unidoes.org 1 /6 - Rev. 10/01 /18 <br />