Laserfiche WebLink
•O • PISTON SEALED REGISTER <br /> w •-• m RETAINER NUT <br /> • � •� DIVISION PLATE <br /> a <br /> • j <br /> C <br /> a <br /> • -Y DIRECTION <br /> a � ..- n .... .1�.. I OF FLOW m "a0000a a <br /> C <br /> s PISTON CONTROL STRAINER MAGNETIC <br /> ROLLER COUPLING <br /> A <br /> 2"(ON 50mm)DIALS SHOWN <br /> Dimensions and Net Weights <br /> NUMBER <br /> BOLT OF BOLT <br /> METERSIZE CONNECTIONS A B C D WIDTH CIRCLE BOLTS SIZE NET WEIGHT* <br /> Flanged 13 6-718 2-21132 518 8-314 4 2 518 26 lbs. <br /> 1-1/2• (330mm) (175mm) (68mm) (16mm) (222mm) (102mm) (16mm) (12 kg) <br /> (ON 40mm) Screwed 12-5/8 6-7/8 2-21/32 N/A" 8-3/4 N/A" N/A" N/A" 23 lbs. <br /> (322mm) (175mm) (68mm) (222mm) (10.5 kg) <br /> Flanged 17 7-17/32 2-518 518 9-11116 4-112 2 3/4 42 lbs. <br /> 2" (432mm) (192mm) (67mm) (16mm) (246mm) (115mm) (19mm) (19 kg) <br /> (DN 50mm) Screwed 15-114 7-17/32 2-5/8 NIA"' 9-11116 N/A"' j NIA... j N/A"' 37 lbs. <br /> (388mm) (192mm) (67mm) (246mm) (17 kg) <br /> 'Rocksyn measuring chamber <br /> Meter is available with either flanged or screwed end connections.Flanged end meter illustrated to show oval flange and bolt pattern. <br /> End connection threads: "1-1/2"(ON 40mm)-1-112"N.P.T.Internal Threads or 1-la'ISO R-7 International Threads,if specified <br /> "'2"(ON 50mm)-2"N.P.T.Internal Threads or 2"ISO R-7 international Threads,if specified. <br /> Remote Systems—For use with all sizes of Sensus Water Meters <br /> The TouchRead® Automated Meter Reading and Billing Sys- for pit-set meters. It uses a data transfer module factory sealed to <br /> tem—is a multi-purpose encoded remote system suitable for the top of the register.The TouchRead Convertible(TRC)register <br /> indoor and/or outdoor use. The Electronic Communications can later be field converted to be compatible with centralized auto- <br /> Register(ECR)uses a wired connection between the meter and matic meter reading.All versions can be read with a visual reading <br /> an outside remote TouchPad data transfer module. device, and/or a TouchRead System Interrogator/Recorder. For <br /> With a TouchRead PitLid(TR/PL)module, pit-set meters can be detailed information on TouchRead System equipment refer to <br /> read automatically without lifting the meter box lid. The meter bulletins RS-983,TR-984,RS-990 and TR-995. <br /> register, factory sealed to the PitLid module, is interrogated by Self Generating Remote (GTR)—In the GTR remote system a <br /> touching a PitProbe to a lid mounted module to read and store meter generates and transmits an electrical pulse via a wired <br /> meter data,even in flooded pits. connection to a remote totalizer. The meter's generator unit is <br /> A non-remote version of the TouchRead®System is also available submersible. See data sheet RS-966. <br /> Sensus <br /> 4 0 N.G 18 <br /> SeNSUS Box etin Avetnuelnc. AUTHORIZED DISTRIBUTOR <br /> T E C H N 0 L 0 6 1 E S, I N C. Uniontown,PA 15401 <br /> TOLL FREE HOTLINE <br /> 1-800-METER-IT <br /> A BTR Company 1-800-638-3748 <br /> .air+ <br /> Rrr sen voe <br />