Laserfiche WebLink
SECTION 3.0:ELECTRIC TRANSMISSION <br /> FAA and is provided in Appendix 5.6C. See Section 5.6,Land Use, and Section 5.12,Traffic <br /> and Transportation,for additional information regarding aviation. <br /> 3.4.4 Fire Hazards <br /> The proposed 230-kV transmission interconnection will be designed, constructed, and <br /> maintained in accordance with applicable standards including GO-95,which establishes <br /> clearances from other manmade and natural structures, as well as tree-trimming <br /> requirements to mitigate fire hazards. PG&E will maintain the transmission line corridor <br /> and immediate area in accordance with existing regulations and accepted industry practices <br /> that will include identification and abatement of fire hazards. <br /> 3.5 Laws, Ordinances, Regulations, and Standards <br /> This section provides a list of applicable LORS that apply to the proposed transmission line, <br /> substations, and engineering. <br /> 3.5.1 Design and Construction <br /> Table 3.5-1 lists the LORS for the design and construction of the proposed transmission line <br /> and substations. <br /> TABLE 3.5-1 <br /> Design and Construction LORS for the Proposed Transmission Line and Substations <br /> LORS Applicability <br /> Title 8 CCR, Section 2700 et seq. "High Establishes essential requirements and minimum standards for <br /> Voltage Electrical Safety Orders" installation, operation, and maintenance of electrical installation and <br /> equipment to provide practical safety and freedom from danger. <br /> GO-52, CPUC, "Construction and operation Applies to the design of facilities to provide or mitigate inductive <br /> of power and communication lines for the interference. <br /> prevention or mitigation of inductive <br /> interference" <br /> GO-95, CPUC, "Overhead electric line CPUC rule covers all aspects of design, construction, operation, and <br /> construction" maintenance of electrical transmission line and fire safety(hazards). <br /> GO-128, CPUC, "Construction or' Applies to the design and construction of underground transmission <br /> underground electric supply and lines. <br /> communication systems" <br /> ANSWEEE 593, "IEEE Recommended Recommends design and construction practices. <br /> Practices for Seismic Design of <br /> Substations" <br /> IEEE 1119, "IEEE Guide for Fence Safety Recommends clearance practices to protect persons outside the <br /> Clearances in Electric-Supply Stations" facility from electric shock. <br /> IEEE 998, "Direct Lightning Stroke Recommends protections for electrical system from direct lightning <br /> Shielding of Substations" strikes. <br /> IEEE 980, "Containment of Oil Spills for Recommends preventions for release of fluids into the environment. <br /> Substations" <br /> 3-10 SAC13713221082350006(LEC_3.0_ELECTRANS.DOC) <br />