My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS LEC APPLICATION FOR CERTIFICATION
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
12751
>
2900 - Site Mitigation Program
>
PR0516806
>
ARCHIVED REPORTS LEC APPLICATION FOR CERTIFICATION
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2019 8:41:30 AM
Creation date
9/25/2019 4:52:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
LEC APPLICATION FOR CERTIFICATION
RECORD_ID
PR0516806
PE
2965
FACILITY_ID
FA0012817
FACILITY_NAME
WHITE SLOUGH WATER POLLUTION CONTRO
STREET_NUMBER
12751
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95241
APN
05513016
CURRENT_STATUS
01
SITE_LOCATION
12751 N THORNTON RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1599
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
® WorleyParsons <br /> resources&energy <br /> 5.3.1.1 Operator Workstation <br /> The balance of plant DCS will include one operator workstation. The workstation will be <br /> equipped with one keyboard and one 19" LCD Flat Panel Monitor. The monitor will be <br /> located on the work desk provided in the Plant Main Control Room. <br /> 5.3.1.2 Printers <br /> One color inkjet printer will be provided and will be located on the work desk in the Plant <br /> Main Control Room. <br /> 5.3.2 DCS Processors, I/O Cabinets and Hardware <br /> Processors, power supplies, communication modules, input and output modules will be <br /> mounted in a freestanding cabinet with front access. Redundant circuits in separate <br /> raceways will provide 125 VDC power to the DCS processors. The operator workstation <br /> and printer will be powered from the plant UPS system. <br /> The system will be provided with 10 percent spare wired I/O and 10 percent spare slots in <br /> each cabinet at system shipment. <br /> Equipment and termination blocks will be identified either with laminated phenolic <br /> nameplates or stamped metal tags. <br /> 5.3.3 DCS Functionality <br /> The control system will show an overview and grouped or detailed information to assist the <br /> operator in required control actions. Functional logic diagrams or ladder logic diagrams <br /> will be provided to the DCS supplier. <br /> Motor control logic will be coordinated to offer consistent functionality for all balance of <br /> plant equipment. Likewise, the operator interface for such logic will also be consistent. <br /> Permissive displays will be provided for applicable motors and valves identifying all <br /> system interlocks. Permissive displays will be developed either as a paged display <br /> associated with a given graphic or a pop-up display. <br /> All alarm annunciation will be done in the balance of plant DCS. The sequence of events <br /> (SOE) function will have a resolution of not more than I millisecond and will be an <br /> integral part of the DCS. The CTG sequence of events will be synchronized with the same <br /> time stamp as the BOP or hard wired points to the BOP DCS to allow comprehensive SOE <br /> reports to be generated by the BOP DCS. <br /> 5.3.4 Graphics <br /> A maximum of ten process graphics with an ISA-based symbol set, 10 trend displays, and <br /> 10 permissive displays that show the status of system interlocks will be included in the <br /> Lodi Energy Center 3.5 -3 LEC AFC <br /> 071608 Rev.A <br />
The URL can be used to link to this page
Your browser does not support the video tag.