My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS LEC APPLICATION FOR CERTIFICATION
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
12751
>
2900 - Site Mitigation Program
>
PR0516806
>
ARCHIVED REPORTS LEC APPLICATION FOR CERTIFICATION
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2019 8:41:30 AM
Creation date
9/25/2019 4:52:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
LEC APPLICATION FOR CERTIFICATION
RECORD_ID
PR0516806
PE
2965
FACILITY_ID
FA0012817
FACILITY_NAME
WHITE SLOUGH WATER POLLUTION CONTRO
STREET_NUMBER
12751
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95241
APN
05513016
CURRENT_STATUS
01
SITE_LOCATION
12751 N THORNTON RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1599
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
® WorleyParsons <br /> resources&energy <br /> conditions of each application as listed in the Data Sheets. <br /> The valve body size will not be less than two pipe sizes smaller than the nominal inlet <br /> pipeline size, unless otherwise specified. <br /> Bellow seal bonnets will be used for highly toxic or volatile fluids. Teflon or approved <br /> non-asbestos alternate packing material may be used for temperatures between -40°F and <br /> 450°F. Grafoil packing will be used as a minimum for temperatures 450°F and above. <br /> Solenoid valves supplied with the control valves will have Class H coils 120 VAC UPS <br /> powered. The coil enclosure will normally be a minimum of NEMA 4 but will be suitable <br /> for the area of installation. Terminations will typically be by pigtail wires. <br /> 5.6.6.1 End Connections <br /> Steel valves with flanged ends will be in accordance with ASME B16.5. End to end <br /> dimension of each valve will be in accordance with the appropriate ISA Standards (i.e. ISA <br /> 575.03 and S75.04). <br /> All welding connections for valves 2-1/2 inches and larger in nominal size will be butt- <br /> welded. All welding connections for valves 2 inches and smaller in nominal size will be <br /> socket welded. All welding ends will be in accordance with ASME B 16.34 and B 16.25. <br /> Control valves in 300# class service and below will be flanged, except for Hydrogen, <br /> Natural Gas, Ammonia, steam and vacuum service. Where flanged valves are used the <br /> flange rating will match the pipe class specifications. <br /> All control valves 600# and greater will be furnished with weld end connections. <br /> For butterfly, ball, and similar body types, lugged or flanged bodies to permit dead end <br /> service will be provided unless otherwise specified. Wafer types that cannot be <br /> independently fastened to the field piping at both ends of the valve body will not be <br /> provided. <br /> 5.6.6.2 End extensions and Reducers: <br /> If the size of a welded end valve is different than the field pipe size, the valve will be <br /> furnished with shop welded concentric reducers matching the upstream and downstream <br /> pipe size, material and wall thickness. Shop welded end extensions will be provided for <br /> valves with body material that is different than the field piping material (such as alloy <br /> valve bodies to be welded into carbon steel pipelines or vice versa). End extensions will be <br /> a pipe section at least 6 inches (150 mm) long. End extensions and reducers will be factory <br /> installed on the valve body and stress relieved in accordance with ASME B31.1. End <br /> extensions and reducers will be shown on the valve drawing and included in the shop end- <br /> to-end or center-to-face dimensions. <br /> Lodi Energy Center 3.5- 10 LEC AFC <br /> 071608 Rev.A <br />
The URL can be used to link to this page
Your browser does not support the video tag.