Laserfiche WebLink
Table 5.1A-1 <br /> NCPA Lodi Energy Center <br /> Emissions from the Existing Gas Turbine <br /> Parameter <br /> Standard Temp (F) 60 Device Gas Turbine <br /> Heat Input Rate (MMBtu/hr) 463 Make General Electric <br /> Power Generation (MW) 49 Model LM5000 <br /> Exhaust 02 Conc 0.00% Fuel Natural Gas <br /> CO2 F-Factor(dscf/MMBtu) 1,040 <br /> Exhaust Flow Rate (dscfm) 67,212 <br /> Higher Heating Value (Btu/Ib) 22,525 <br /> Daily Operating Hours 24 <br /> Annual Operating Das 365 <br /> Exhaust Emission Maximum Emissions <br /> Concentration Factors Hourly Daily Annual <br /> Pollutant mvd a 15% 02 Ib/MMBtu Ib Ib tons <br /> CO 13 0.029 13.4 322 58.8 <br /> NOx 3.0 0.011 5.20 112 20.4 <br /> PM10 ---->gr/dscf 0.0035 0.004 2.0 48 F8.8 <br /> SOx (as SO2) 0.5 0.0028 1.30 31 5.7 <br /> VOC as CH4 10 0.0128 5.92 142 25.9 <br /> Notes <br /> 1. Standard temperature as specified in Section 3.47 of Rule 1020 of the SJVUAPCD Rules and Regulations. <br /> 2. Fuel consumption (in MMBtu/hr) is limited by Permit Condtion 22. <br /> 3. Power generation is specified in the Permit to Operate. <br /> 4. Exhaust 02 concentration corresponds to the USPEPA f-factor. <br /> 5. CO2 F-factor obtained from 40 CFR Part 60, Method 19. <br /> 6. Exhaust flow rate calculated from heat input rate and the USEPA F-factor from 40 CFR Part 60, Method 19. <br /> 7. Fuel sulfur content (in gr/100 scf) is limited by Permit Condition 35. <br /> 8. Higher heating value (in Btu/Ib) corresponds to a higher heating value of 1,004 Btu/scf. <br /> 9. Daily NOx, CO, and VOC emissions are limited by Permit Conditions 31, 33, and 34, respectively. Hourly <br /> emissions of CO and VOC were calculated from the daily emissions and the daily operating hours. Exhaust <br /> concentrations (in ppmv @ 15% 02)were calculated from the hourly emission rate, exhaust flow rate, exhaust <br /> 02 concentration, and reference 02 concentration. Hourly NOx mass emissions were calculated from the <br /> NOx concentration limit in Condition 27. <br /> 10. Daily PM10 emissions are limited by Permit Condition 22. Hourly emissions were calculated from the daily <br /> emissions and the daily operating hours. Exhaust PM 10 concentration (in gr/dscf @ 12% CO2)was calculated <br /> from the hourly emission rate, heat input rate, CO F-factor, and reference CO2 concentration. <br /> 11. Hourly SOx emissions were calculated from the heat input rate (in MMBtu/hr), the higher heating value (in <br /> Btu/Ib), and the fuel sulfur content(in gr/100 scf). Daily SOx emissions were calculated from the hourly <br /> emissions and the daily operating hours. Exhaust SOx concentration (in ppmv @ 15% 02)was calculated from <br /> the hourly emission rate, exhaust flow rate, exhaust 02 concentration, and reference 02 concentration. <br /> 12. Except for SO2, emission factors (in Ib/MMBtu)were calculated from the hourly emission rate (in Ib/hr)and <br /> the heat input rate (MMBtu/hr). For SO2, the emission factor(in Ib/MMBtu)was calculated from the fuel sulfur <br /> content limit and the heat content of the natural gas fuel. <br /> 13. Annual emissions were calculated from the daily emissions and annual operating days. <br />