Laserfiche WebLink
Table 5.1 D-5 <br /> NCPA Lodi Energy Center <br /> Calculation of Modeling Inputs and HHls for Aux Boiler Acute and Chronic Risk Assessment <br /> Acute Health Impacts Chronic Health Impacts <br /> Annual <br /> Max Hourly HARP Acute HHI Average HARP Chronic HHI <br /> Emissions, Acute HI Model Input Emissions, Chronic HI Model Input <br /> Compound g/s (per ug/m3) (Note 1) g/s (per ug/m3) (Note 1) <br /> Propylene 4.32E-03 -- -- 2.31 E-04 3.33E-04 7.69E-08 <br /> Acetaldehyde 2.53E-05 -- -- 1.35E-06 1.11E-01 1.50E-07 <br /> Acrolein 2.20E-05 5.26E+00 1.16E-04 1.18E-06 1.67E+01 1.96E-05 <br /> Benzene 4.73E-05 7.69E-04 3.64E-08 2.53E-06 1.67E-02 4.22E-08 <br /> 1,3-Butadiene -- -- -- -- 5.00E-02 -- <br /> Ethylbenzene 5.63E-05 -- -- 3.01 E-06 5.00E-04 1.50E-09 <br /> Formaldehyde 1.00E-04 1.06E-02 1.06E-06 5.36E-06 3.33E-01 1.78E-06 <br /> Hexane 3.75E-05 -- -- 2.00E-06 1.43E-04 2.87E-10 <br /> Naphthalene 2.45E-06 -- -- 1.31 E-07 1.11 E-01 1.45E-08 <br /> PAI-Is 8.16E-07 -- -- 4.36E-08 -- <br /> Propylene Oxide -- 3.23E-04 -- -- 3.33E-02 -- <br /> Toluene 2.16E-04 2.70E-05 5.84E-09 1.15E-05 3.33E-03 3.84E-08 <br /> Xylene 1.61 E-04 4.55E-05 7.31 E-09 8.58E-06 1.43E-03 1.23E-08 <br /> -F Total = 1.17E-04 Total = 2.18E-05 <br /> Notes: <br /> (1) Units are (g/s)/(ug/m3). <br />