My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS UIC PERMIT APP
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
12751
>
2900 - Site Mitigation Program
>
PR0528038
>
ARCHIVED REPORTS UIC PERMIT APP
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2019 9:59:35 AM
Creation date
9/26/2019 9:22:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
UIC PERMIT APP
RECORD_ID
PR0528038
PE
2950
FACILITY_ID
FA0018998
FACILITY_NAME
NCPA LODI ENERGY CENTER
STREET_NUMBER
12751
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95242
APN
05513016
CURRENT_STATUS
01
SITE_LOCATION
12751 N THORNTON RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1019
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTACHMENT A:AREA OF REVIEW METHODS <br /> injection zone is approximately 800 feet thick,reducing pressure in the formation at great <br /> distances from the well. Additionally,the presence of the extensive confining unit will <br /> prevent the formation fluids from moving between zones, except in locations where there <br /> are conduits. There are relatively few wells in the area (see discussion below). In addition, <br /> there are no known faults or fractures within the Area of Review that could serve as conduit <br /> for upward flow of injectate or poor quality water. Finally,it is not expected that the plants <br /> will operate at full capacity at all times,most likely at lower rates than the proposed <br /> permitted values,resulting in significantly less pressure than calculated based on the <br /> assumptions above. <br /> Based on evaluation of the fixed radius and volumetric methods,a relatively small radius of <br /> investigation of 0.25 to 0.30 miles is required. The allowable pressure increase method at full <br /> permitted rates suggests a radius of approximately 0.8 miles for 10 years and 1.4 miles for <br /> 30 years which appears to be conservative based on actual planned injection rates and an <br /> injection zone in the LEC-1/LEC-2 wells that is thicker than the 230 feet estimated in these <br /> calculations. Based on the calculations summarized above and a desire to be conservative in <br /> selecting the radius of the AOR, a total distance of 2 miles was selected. <br /> Potential Impact of Injection Operations on Wells within Area of Review <br /> The wells penetrating the confining zone within 2 miles are provided in Table A-6. Their <br /> locations are shown in Figure A-5. <br /> TABLE A-7 <br /> DOGGR Wells within 2 Miles of the Site <br /> Total Depth Abandon <br /> API Number Operator Lease Well No. (ft) Spud Date Date <br /> 7700509 Federal Oil Co. Federal 1 4,875 06/02/1955 05/30/1955 <br /> Imeson <br /> 7700518 Ferguson& Perrin 1 4,802 12/14/1962 12/18/1962 <br /> Bosworth <br /> 7720172 Great Basins Rio Blanco 1 5,450 10/14/1972 10/18/1972 <br /> Petroleum Co. <br /> 7720290 Great Basins City of Lodi 1 6,703 11/22/1976 11/30/1976 <br /> Petroleum Co. <br /> 7720345 Venoco, Inc. Ratto 14-1 5,820 10/30/1979 11/05/1979 <br /> 7720381 Argo Petroleum Buttes-Rio 15-77X 4,931 10/13/1981 10/25/1981 <br /> Corp. Blanco <br /> 7720484 Princeton Natural Piacentine 1-27 4,900 07/4/1986 <br /> Gas, LLC <br /> 7720496 Maxus Exploration Red House 65-24 5,762 07/1/1987 07/01/1987 <br /> Co. Fee <br /> 7720568 Northern California Lodi STIG 1 4,650 04/29/1993 <br /> Power Agency <br /> A-8 SAC/371322/082550016(ATTACHMENT-A.DOC) <br />
The URL can be used to link to this page
Your browser does not support the video tag.