Laserfiche WebLink
1 2 @I 3 4 5 PI 6 7 ^I8 9 10 <br /> DIRECT BURIAL COATING SELECTIONS LEGEND: DETAIL LEGEND: <br /> MAIN LINE COATING FILE(E-35.4) —GT— GAS TRANSMISSION LINE(PROPOSED) —w FENCE GAS UNE MARKER(OTHER) QrQ WATER VALVE ----- PROPOSED GAS TRANSMISSION UNE <br /> MINOR REPAIRS LIQUID EPDXY(E-35.3) _ —GT(7)— GAS TRANSMISSION LINE(TO BE TESTED) L�WALLTYPE ISI INSULATION JOINT [tj CABLE TV BOX TIE-IN WELDS LIQUID EPDXY I EASA) WALL --_--- EXISTING GAS TRANSMISSION LINE <br /> GIRTH WELDS LIQUID EPDXY IE-35.11 —GT— GAS TRANSMISSION LINE(EXISTING) 0BARRIER ® PRESSURE CONTROL FITTING ET] TELECOMM BOX <br /> BUTT WELDED FITTINGS LIQUID EPDXY E-35.11 —GO— GAS DISTRIBUTION UNE(EXISTING) _ ___ TEMPORARYGASTRANSMISSION LINE <br /> E VALVEASSEMBUES LIQUID EPDXY JE-35.7),WAX TAPE(E-35.7) —GS— GAS SERVICE LINE(EXISTING) TEMPORARY BARRIER(TYPE K) G❑ GAS BOX (moi'] TELECOMM VAULT (OWNED BY PG&E) E <br /> SHORT SEGMENTS OF PIPE LIQUID EPDXY E-35.1) ---GT--- GAS TRANSMISSION UNE(RETIRED) GUARDRAIL 8 GAS HIGH PRESSURE REGULATOR ® STREET LIGHT BOX -- TEMPORARYGASTRANSMISSIONLINE <br /> AIR-TO-SOILTRANSITIONS LIQUID EPDXY/PSX 7IDE-35.8 ---GD--- GAS DISTRIBUTION LINE(RETIRED) TOE OF SLOPE (OWNED BY OTHERS) <br /> GS GAS SERVICE LINE(RETIRED) <br /> PRESSURE CONTROL FITTINGS LIQUID EPDXY(E-35.7),WAX TAPE(E-35.7 - --^------ TOP OF SLOPE ® GAS METER TREE RETIRED GAS TRANSMISSION LINE <br /> - --- <br /> TIE-INS/COATING RANSITIONSI LIQUID EPDXY(E-35.31 OWNER /-EP ® GAS DISTRICT REGULATOR ® ANODE <br /> BORED COATING SELECTIONS r_..-.._.. FOREIGN GAS LINE EDGE OF PAVEMENT GAS TRANSMISSION UNE <br /> rT{ Q PG&E GAS MANHOLE ❑A DEEPWELLANODE -""--"" (TO BE REMOVED) <br /> MAIN LINE COATING ARO APPLIED OVER FEE(E-31S.4) —IT— JOINTTRENCM FACE OF CURB COMPUTER AUTOMATED <br /> MIN,ORREPAIRS LIQUID EPDXIES(E-35.2) —ET— ELECTRIC TRANSMISSION LINE /--BW ® GAS VAULT UT TEST STATION CUT LINE(TO BE REMOVED) <br /> TIE-IN WE <br /> LIQUID EPDXIES(E-35.2) —ED— ELECTRIC DISTRIBUTION LINE BACK OF WALK ® GAS VENT ® AC COUPON TEST STATION ----- EXISTING GAS DISTRIBUTION LINE <br /> NOTES: - - - - DASHED PAVEMENT MARKINGS <br /> IIPDFREII(E[aNSIRpCIpN MDn:Io.cW.nxq REouINMExrs —ES— ELECTRIC SERVICE LINE UNPAVED ROAD GAS VALVE RS COUPON TEST STATION <br /> ----- <br /> —ETGH— ELECTRIC TRANSMISSION OVERHEAD RAILROAD © PG&E ELECTRIC MANHOLE ® ELECTROLYSIS TEST STATION PROPOSED GAS DISTRIBUTIONUNE <br /> INTERNAL CORROSION(IC) —EDOH— ELECTRIC DISTRIBUTION OVERHEAD <br /> DESIGN&CONSTRUCTION REVIEW ®E EIECTRICVAULT ® POLE-MOUNTED RECTIFIER ARVW949KM TOP OF GRADE <br /> —1— TELEPHONE UNE ACCESS ROAD <br /> IC THREAT YES NO FIBEROPTICUNE UTILITY POLE(ELECTRIC) FD MI DO MITIGATION CABINET M GASVALVE <br /> D (PER TD4810P-16) NA NA —P.— CABLETV LINE LAYDOW /STAGING/ UTILITY <br /> UTILITY POLE(OTHER) POTHOLE <br /> DATE 1 PIPE END CIT(SIDE) <br /> IC REVIEW COMPLETED BY STORM DRAIN LINE SEWER LINE " O JOINT POLE CIT/COUNTY MONUMENT <br /> UN ID <br /> (CORROSION ENGINEER OR DESIGNATE) EXCAVATION/BELL HOLE ® PIPE ENO CIT <br /> —W— WATERLINE ® EXISTING ELECTRIC TOWER MONUMENT,SEE DESCRIPTION <br /> CORROSIONE NDINCORPORATREVIEWED FLOW FLOW ARROW <br /> THISDESIGN DEIGN AND <br /> DRANSTRUC --UNY,-- UNKNOWN UTILITIES O Q SURVEY CONTROL POINT <br /> CON NARY IC DESIGN OF SAFET ZONE UMTS STORM DRAIN INLET <br /> CONSIDERATIONS.DOCUMENTATION OF NA NA C===.7 USING Q CENTERLINE . TIE-IN WELD <br /> THE REVIEW AND ACTIONS NDINCORPORATED <br /> ARE IN ENVIRONMENTALLY UTILITY MANHOLE <br /> PROPERTY BOUNDARY x5 MATERIAL OF RECORD ASSET <br /> TME LOB PACIfAGE AND INCORPORATED IN -"-""-"'-"-"' SENSITIVE AREAS <br /> THUS DESIGN. ---- PG&E EASEMENT ® WATER METER <br /> EDITS ROUTING NUMBER: NA TEMPORARY EASEMENT sQ� BILL OF MATERIALS ASSET <br /> -r"_IW_ <br /> FOREIGN RIGHT-0F-WAY <br /> INSTALLATION TESTED OR INSPECTED AND <br /> NOTED ON DRAWING. -•.'�-• ULTRANS RIGHT-0F-WAY <br /> ALL CORROSION LEVELS SATISFACTORY PER <br /> PG&E GAS UTILITY STANDARD TD-41815. <br /> C QUALIFIED EMPLOYEE DATE Acronym Definition Acronym Definition Acronym DefinRJun Acronym Definition Acronym Definition C <br /> CORROSION MECHANIC'S SIGNATURE 15 (E1 Existing DEG Degree HIM, High Freq uenry Weld PKWY Parkway TEMP Temporary <br /> REQUIRED WHEN A CPA BOUNDARY IS (P) Proposed DET Detail HPR High Pressure Regulator PL Plastic TG Top of Grade <br /> WITHIN THE SCOPE OF THE PROJECT. AB Aggregate Bae DFM Distribution Feeder Main HWY Highway PLC Is egrammagle Logic Controllers TT Top Tap <br /> ABN Abandon DI Drainage Inlet ID Inside Diameter PRUPF Procedure for the Resolution of TSP Transmission System Planning <br /> AC Asphalt Concrete OW Diameter ILI In-Line Inspection Unknown Pipeline Features TYP Typial <br /> API American Petroleum Institute DIST Distribution INV Invert PSI Pounds per Square Inch UG Underground <br /> APN Assessor's Parcel Number DW Damage Prevention Volume IRR Irrigation PV Plug Valve USA Underground Service Alert <br /> APPApproximate DR Distribution Regulator 1N lob Number "MT Pavement UT Ultra-Sonic Test <br /> AVE Avenue DREG DnAct Regulator 1P Joint Pole QTY Quantity V Valve <br /> ARC Abrasion Resistant Coating DSAW Double Submerged Arc-Welded IT Joint Trench R Radius VIF Verify in Fleur <br /> ASME American Sudety of Mechanical Engineers DWA Deep Well Anotle L Une Number RCP Reinforced Concrete Pipe VOL Volume <br /> ASTM American Society for Testing Mateciais DWY Driveway LAT latitude RO Read W Water <br /> 'BCI Bell Bell Chill Ring E East LN Lane RDWY Roadway WT Wall Thickness <br /> BC Begin Curve EASE Easement LNG Uquld Nat ural Gas REG Regulator WV Water Valve <br /> BD Slowdown EC End Curve LOC Location REL Relocate W/ With <br /> BEG Begin EL Elbow LONG Longitude REPL Replace W/0 Without <br /> BKF Backfill ELECT Electric LT Left REV Revhion WP Work Procedure <br /> BLDG Building ELEV Elevation M Monitor RR Railroad <br /> BLVD Boulevard EM Electronic Marker MAOP Maximum Allowable Operating Pressure RT Right <br /> BM Bench Mark EMS Engineering Material Specification MA% Maximum RTE Route <br /> B BMP Best Management Practice ENGR Engineer MH Manhole R/W Right of Way B <br /> BOM Bill of M aterials EP EdBe of Pavement MIN Minimum S South <br /> BR Bridge EQ Equation MISC Miscellaneous SAWH Submerged Arc-Welded Helical <br /> BTU British Thermal Units ERW Electric Resistance Welded MLV Main Line Valve SAWL Submerged Arc-Welded Longitudinal <br /> BV Ball Vaive ESA Environmentally Sensitive Area M01 Methed of Installation SCADA Supervisory Control and Data Acquisition <br /> But Back of Walk as Electrolysis Test Station MON Monument SO Storm Drain <br /> LITS Computer Automated Test Station ETW Edge of Traveled Way MOP Maximum Operating Pressure SG Sheet <br /> CCorrosion Control Volume F Filer MP Mile Point SHIT Sheet <br /> ClI Cart Iron F&C Fame and Cover MSP Maximum Stopping Pressure SMLS Seamless <br /> CL CemeHite FBE Fusion Bonded Epoxy MW Meter SMYS Specified Minimum Yield Strength <br /> CMP Corrugated Metal Pipe FC Face of Curb MW Working Monitor SPEC Specification <br /> CNG Compressed Natural Gas FDP Future Design Pressure MWP Maximum Working Pressure SS Sanitary Sewer <br /> CO County F6 FireHydande N North SSAW Single Submerged Arc-Welded GIMATINSMIDESIG <br /> COND Concrete FH Fre Hydrant NDE Normal Operating <br /> g Pressure ST Street ESTIMATING&DESIGN <br /> N <br /> COND Conduit FIG Figure NOP Normal Operating Pressure STA Statbn <br /> CP Cathodic Protectlan FL Flow Une NPC Non Protected/Native Coupon STD Standard <br /> CPT Catch Point FLG Flange NTS Not,Scale STL Steel <br /> CROP Condklonai Reduction of Pressure FWY Freeway OD Outside Pipe Diameter STPR Strength Test Pressure Report <br /> CTS Coupon Test Station GS Natural Gas Service OG Original Ground T Tied(Connected to System) <br /> CU Coppeer GS&S Gas Standards and Specifications OH Overhead TCE Temp only Construct ion Easement <br /> CUL, Culu rt GV Gate Valve P Pipeline TCP Traffic Control Plan - (f <br /> D Depth GW Natural Gas Well P/L Property line TD Technical Document <br /> A DE Dead End 11 Horizontal PC Point of Curvature TDW T.D.Wllllzmsen A <br /> DCUST Distribution Customer HDD Horizontal Directional Drill PCF Pressure Control Fitting TEL Telephone - <br /> WARNING: .. sra <br /> 6pocusa—r urK • PIPELINE-LEGEND&STAMPS <br /> m MNTUL-111 TAM INSTALL200'DEEPWELLANODE <br /> nan—arqty TaTBTH-E • ,D C 1331 <br /> PROPERTY OE PA—G,at AND DFM 1611-03 MP 1.83 xe e <br /> LL xRXCOMPAWAxon STOCKTON,S=IN COUNTY <br /> FDP U9E ONLY BY <br /> �1�NORNFO PY�iIC GASAND dRe.rEEe ■. 9 NIH19 EMCeaimU[TNxI W9TPwN5MGwxA orsPMwrnN xETNO. 3 or F flHli <br /> EUMICCOMPANYEMP..Es 0 u�Praw <br /> ANDna AGENTS. C81he1drolledd)g. PACIFIC GASAND ELECTRIC COMPANY 7401930070 <br /> ._E. <br /> _EmREVISIONS SAN FRANCISCO,CALIFORNIA <br /> 1 2 $I 3 4 5 91 6 7 a(8 t !9 1 10 P z <br />