Laserfiche WebLink
z S A N A A Q U I N Environmental Health Department <br /> COUNTY--- <br /> Linda Turkatte, REHS, Director <br /> Greotness grows here. Kasey Foley,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon. REHS <br /> Jeff Carruesco. REHS, RDI <br /> Michael Kith. REHS <br /> Willy Ng, REHS <br /> COPY Nluniappa Naidu. REHS <br /> 08/19/2019 <br /> Tracy Fire Department <br /> 1400 Durham Ferry Rd <br /> Tracy, CA 95304 <br /> RE: Well Pump Inspection <br /> Well Location: 1400 Durham Ferry Rd. Tracy, CA Permit#: WP0039915 Inspection Date: 08/15/2019 <br /> The Environmental Health Department recently conducted a water well purnp inspection at the above address <br /> and found the following issues at the time of the inspection. In order to protect the ground water supply and <br /> your water source from potential degradation, please take the associated corrective actions. <br /> FX- Lack of Concrete Platform around Wellhead. <br /> (SJC Water Well Standards, Section 4.10.—Surface Seal) <br /> Corrective Action: Install a new concrete platform around the wellhead that extends two feet in all <br /> directions from the well casing. <br /> ❑ Lack of or Inadequate Sanitary Seal at Wellhead. <br /> (SJC Ord. Code, Title 9. Section 9-1115.5.—Well Regulations) <br /> Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br /> openings. <br /> ❑ Lack of or Inadequate Sampling Tap. <br /> (SJC Water well Standards, Section 4.13.—Sampling Tap) <br /> Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br /> or within three (3) feet of the well head. <br /> ❑ Lack of or Inadequate Backflow Prevention. <br /> (SJC Water Well Standards, Section 4.14.—Backflow Prevention) <br /> Corrective Action: Install an approved protective device to prevent backflow and/or back <br /> siphonage into a well. <br /> ❑ Sounding Tube or Air Vent not Sealed. <br /> (SJC Water Well Standards, Section 4.13.—Sounding Tube/Air Vent Pipe) <br /> Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br /> of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br /> downward direction and covered with 16-rnesh screening. <br /> ❑ Excessive Vegetation or debris around Wellhead. <br /> (SJC Ord. Code, Section 9-1115.4.—Dangerous/Nuisance) <br /> Corrective Action: Remove and maintain debris and vegetation away frorn well area. <br /> If you have any questions. contact: Aaron Gooderham, Environmental Health Assistant (209) 468-3442, <br /> Please call when work is complete. <br /> F <br /> �Mic ael Kith, REHS <br /> Program Coordinator <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www,sjcehd.com <br />