Laserfiche WebLink
• <br /> the faci-7 -4 =7 is one hundred --__es less tan = e resulatOr7 <br /> levels, and since no floating product or other constituent was <br /> • detected, it appears that no remedial action is warranted at this <br /> time . <br /> • <br /> RECO MME DAT10YS <br /> Since there is a possibility of seasonal changes at the site, we \ <br /> • recommend that quarterly monitoring be undertaken for a period of <br /> one year . This monitoring should encompass the following tasks : <br /> 1 . Measure distance to free water surface . <br /> • <br /> 2. With clear plastic bailer, check water surface for free <br /> floating product . <br /> 3. Pump well to purge until five to ten well volumes have <br /> • been removed or until two of the following parameters <br /> have stabilized : <br /> P3 <br /> • electroconductivity <br /> temperature <br /> If a well does not contain enough water to pump <br /> • continuously, then it will be pumped dry, and then <br /> sampled after it has recovered. <br /> • <br /> • <br /> 4 <br />