PE
2231
FACILITY_ID
FA0003680
FACILITY_NAME
CALIFORNIA TANK LINES INC
STREET_NUMBER
3105
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17512028
CURRENT_STATUS
01
SITE_LOCATION
3105 S EL DORADO ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
716
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DAILY <br />C.ieck pumps for proper operation <br />Check caustic and acid tanks <br />Check grease separator and flow <br />rate <br />�. <br />Check storage tanks and all piping <br />for leaks <br />Clean PH probes <br />}-- <br />Check Safety Gear <br />�c <br />Clean & Check all Eye 'Wash and <br />Safety Showers <br />- <br />Cleaned Containment Area <br />ry <br />WEEKLY <br />Clean grease separator <br />Calitxate Oxygen N•oniior <br />Clean solids from PH adjusting <br />tank <br />Clean & Calibrate PH probes - <br />Tuesday Thursda 8 Saturda <br />REPAIRS <br />I COMMENTS <br />CALIFORNIA TANK LINES, INC. <br />WASHRACK MAINTENANCE LOG <br />METHOD OF CALIBRATING <br />STEP I Begin with PH7 solution, let probe remain in solution for approximately 15 minutes, or until a stable reading is obtained <br />STEP II Same as above with PH4 solution. <br />STEP III Same as above with PHI solution. <br />SIGN & DATE <br />NONE <br />MEN <br />M <br />N <br />ME <br />I <br />METHOD OF CALIBRATING <br />STEP I Begin with PH7 solution, let probe remain in solution for approximately 15 minutes, or until a stable reading is obtained <br />STEP II Same as above with PH4 solution. <br />STEP III Same as above with PHI solution. <br />SIGN & DATE <br />
The URL can be used to link to this page
Your browser does not support the video tag.