Laserfiche WebLink
C. <br /> KRAZY ROLLS KIOSK NO REV & DATE <br /> GENERAL PROJECT NOTES: <br /> 1 . WHERE NEW WORK TIES INTO EXISTING CONTRACTOR SHALL PATCH AND <br /> REPAIR EXISTING CONSTRUCTION AS REQUIRED TO RESTORE IT TO ITS <br /> ALBERT VEGA ORIGINAL FINISH , TIE THE NEW WORK INTO EXISTING IN A NEAT AND a <br /> CRAFTSMAN LIKE MANNER SO THAT NEW BLINDS WITH A SMOOTH AND j <br /> LEVEL SURFACE INTO ADJACENT WORK . 0 < E <br /> 2 . ALL NEW WALL FINISHES ( COVERINGS AND PAINTS) SHALL HAVE A FLAME o <br /> 4950 PACIFIC AVE . on- <br /> SPREAD RATING OF 25 AOR LESS . F o 06 <br /> 3 . ALL INSULATION MATERIALS , INCLUDING FACINGS , SUCH AS VAPOR BARRIERS Z N <br /> OR BREATHER PAPERS INSTALLED WITHIN FLOOR - CEILING ASSEMBLIES , at <br /> STOCKTON , CA 95207 ROOF- CEILING ASSEMBLIES , WALLS , CRAWL SPACES OR ATTICS , SHALL HAVE " o � o � <br /> A FLAME SPREAD RATING NOT TO EXCEED 25 AND A SMOKE DENSITY NOT W � v (60 -02 <br /> TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH U . B . C . STANDARD NO . - Q <br /> WEBERSTOWN MALL 4 . W 8 - 1 AND G . B . C . SECTION 707 . <br /> WHEN INSTALLING DRILLED - IN ANCHORS AND/OR POWDER DRIVEN PINS IN <br /> EXISTING NON - PRESTRESSED REINFORCED CONCRETE , USE CARE AND <br /> CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING <br /> SCOPE OF WORK: GENERAL NOTES : BARS . <br /> NEW PRE - FRABRICATED KIOSK INSIDE PROJECT SHALL COMPLY WITH FOLLOWING CODES : 5 . ALL WORK SHALL BE DONE IN A NEAT AND WORKMAN LIKE MANNER <br /> WEBERSTOWN MALL WITH NEW EQUIPMENT; ACCORDING TO THE BEST TRADE PRACTICE BY THOSE SKILLED IN THE <br /> ELECTRICAL AND PLUMBING . A- 2016 CALIFORNIA BUILDING CODE , PARTICULAR TRADE , EQUIPMENT , FIXTURES , PIPING , ETC . , SHALL BE PLUMB , <br /> 13 - 2016 CALIFORNIA MECHANICAL CODE . LEVEL, SQUARE OR CENTERED ETC . , EQUIPMENT TO BE INSTALLED IN LLI <br /> C - 2016 CALIFORNIA ELECTRICAL CODE , STRICT COMPLIANCE WITH MANUFACTURERS ' RECOMMENDATIONS . 0 <br /> D - 2016 CALIFORNIA PLUMBING CODE . 6 , ALL EXISTING CONDITIONS NOT SHOWN OR INDICATED ON THESE PLANS ARE <br /> INDEX: E - 2016 CALIFORNIA FIRE CODE . TO REMAIN UNCHANGED , FIELD VERIFY EXISTING CONDITIONS AND ALL <br /> T . 1 TITLE PAGE F-ALL OTHER CODES ADOPTED BY THE GOVERNING AGENCIES DIMENSIONS . ANY DISCREPANCY BETWEEN DRAWINGS AND ACTUAL WORK W <br /> A . 0 SITE PLAN HAVING JURISDICTION ON THE PROJECT . SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CORRECTION J <br /> Mom <br /> A . 1 FLOOR PLAN G - 2016 CALIFORNIA ENERGY CODE , PRIOR TO COMMENCING WITH THE WORK , <br /> A . 2 EQUIPMENT PLAN H - 2016 CALIFORNIA GREEN BUILDING STANDARD CODE . 7 . ALL DIMENSIONS ON THE PLANS ARE TO THE FACES OF STUDS OR ~ <br /> A. 3 ELECTRICAL PLAN I - LOCAL ORDINANCE CENTERED ON COLUMN , A- DOOR AND CASED OPENINGS WITHOUT LOCATION <br /> A . 4 ELECTRICAL NOTES & 1 - LINE DIAGRAM DIMENSIONS ARE TO BE FOUR ( 4) INCHES FROM FACE OF ADJACENT <br /> A . 5 PLUMBING PLAN 1 . THE WORD "CONTRACTOR " AS USED HEREIN SHALL MEAN THE PARTITION OR CENTERED BETWEEN PARTITIONS , B - ALIGNMENT TAKE <br /> A . 6 PLUMBING NOTES & DETAIL GENERAL CONTRACTOR , SUBCONTRACTORS AND ALL PERSONS PRECEDENT OVER DIMENSIONS . VERIFY ALL DIMENSIONS AND CONDITIONSS1p <br /> DIRECTLY OR INDIRECTLY EMPLOYED BY ANY OF THEM , AND NOTIFY ARCHITECT OF ANY DISCREPANCIES , �p�oNo MpQ9F�Z <br /> KIOSK PLANS : 2 . CONTRACTOR SHELL COMPLY WITH ALL ORDINANCES , RULES , 8 . THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING UP AND ' <br /> 0 . 0 TITLE PAGE REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AGENCY REMOVING FROM THE JOB SITE ALL TRASH AND DEBRIS IMMEDIATELY UPON Exp 6/JO/2020 <br /> 0 . 1 3D VIEWS HAVING JURISDICTION ON THIS PROJECT AND SHALL NOTIFY COMPLETION OF HIS DAILY WORK . <br /> 1 . 0 - 1 . 13 KIOSK PLANS OWNER IMMEDIATELY UPON BECOMING AWARE THAT ANY ASPECT 9 , CONSTRUCTION SHALL COMPLY WITH APPLICABLE EDITION OF CALIFORNIA 9 C /V <br /> 1 . 14 - 1 . 16 TALL SNEEZE GUARD OF THE PROJECT DESCRIBED HEREIN IS AT VARIANCE THERE BUILDING CODE , ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES , <br /> 1 . 17 - 1 . 19 SHORT SNEEZE GUARD WITH . ORDINANCES , LAWS , REGULATIONS AND PROTECTIVE COVENANTS GOVERNING MORAD ENGINEERING <br /> 1 . 20 GATE DETAILS 3 . CONTRACTOR SHALL PROVIDE CERTIFICATES OF INSURANCE THE WORK . IN CASE OF CONFLICT , THE MORE STRINGENT REQUIREMENT EDMOND MORAD. P.E. <br /> EEr <br /> 1621 KIOSK CROSS SECTIONS CA9R354 <br /> ACCEPTABLE TO OWNER PRIOR TO COMMENCEMENT OF WORK . SHALL GOVERN . MODESTO, <br /> 4 . BY SUBMITTAL OF BID CONTRACTOR WARRANTS TO OWNER THAT 10 . CONTRACTOR AND HIS OR HER SUBCONTRACTOR TO HAVE WORKING (los) 530-050 <br /> ALL MATERIALS AND EQUIPMENT TO BE FURNISHED ARE NEW KNOWLEDGE OF ALL CODES APPLICABLE TO THEIR WORK . f` <br /> BUILDING CODE DATA: Y O <br /> UNLESS NOTED OTHERWISE AND ALL WORK WILL BE OF GOOD 11 . COORDINATE ALL WORK AND CONSTRUCTION SCHEDULING WITH OWNER . J <br /> DESCRIPTION OF USE : FOOD KIOSK co Q IN <br /> OCCUPANCY GROUP : M QUALITY AND FREE FROM FAULTS AND DEFECTS . 12 . THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE BARRICADES , <br /> CONSTRUCTION TYPE : VB 5 . CONTRACTOR SHALL VISIT SITE AND VERIFY ALL EXISTING PROTECTIVE COVERINGS , WARNING SIGNS , ETC , TO PREVENT ANY HARM TO 0 W O <br /> CONDITIONS PRIOR TO SUBMITTAL OF BID . WORKERS , EMPLOYEES AND/OR THE GENERAL PUBLIC . Y Q <br /> SPRINKLERS : NO Z Q <br /> STORIES : 1 6 . CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN HEREIN AND 13 . GENERAL CONTRACTOR SHALL MAKE AVAILABLE COMPLETE SETS OF JV 0 <br /> REPORT ALL DISCREPANCIES TO OWNER PRIOR TO SUBMITTAL CONSTRUCTION DOCUMENTS TO HIS OR HER SUBCONTRACTORS FOR REVIEW , J 0 LL Zlot <br /> OF BID . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE , FOR REVIEWING THE <br /> 7 . WHERE CONSTRUCTION DETAILS FOR A PART OF THIS PROJECT COMPLETE SETS AND COORDINATING ITEMS WHICH PERTAIN TO HIS OR HER 0 ~ (� 0 <br /> cc ARE NOT SHOWN THE WORK SHALL BE THE SAME AS OTHER WORK WITH OTHER TRADES PRIOR TO COMMENCING WITH THE WORK . ,maw <br /> SIMILAR WORK FOR WHICH DETAILS ARE SHOWN . 14 . THE CONTRACTOR SHALL PROVIDE MOUNTING PLATES AS REQUIRED BEHIND W I[L <br /> 8 . FIXTURES , APPLIANCES , FINISHES BRAND NAME AND COLORS NOT ALL WALL MOUNTED ITEMS SUCH AS HANDRAILS , GRAB BARS , TOILET i V <br /> m 00 <br /> MENTIONED ON THESE PLANS , SHALL BE PER OWNERS CHOICE , PARTITIONS , LIGHT FIXTURES , EQUIPMENT, ETC . IY LLJ LO � <br /> CONTRACTOR SHALL CONTACT OWNERS PRIOR OF BID , 15 . IT IS NOT INTENDED THAT THE CONTRACT DOCUMENTS INCLUDE EACH AND Y d- (n <br /> PURCHASE AND INSTALLATION OF SUCH ITEMS . EVERY SUBSYSTEM AND SUB - COMPONENT NECESSARY TO FULLY AND <br /> 9 , ALL WORK PERFORMED IN THE CONNECTION WITH THESE PROPERLY COMPLETE THE WORK , SUBSYSTEMS , SUB - COMPONENTS OR DATE: 06 - 10 - 19 <br /> CONTRACT DOCUMENTS SHALL COMPLY WITH ALL STATE , LOCAL DETAILS REQUIRED OR NORMALLY INCLUDED AS TRADE PRACTICE MAY NOT DRAWN BY : R . ORTIZ <br /> CODES AND ORDINANCES IN EFFECT AT THE TIME OF BE SPECIFICALLY MENTIONED OR SHOWN , NEVERTHELESS , CONTRACTOR <br /> CONSTRUCTION . SHALL BE RESPONSIBLE FOR EACH ELEMENT OF THE WORK . JOB NO: <br /> 10 . PROVIDE A CHEMICAL TOILET ON SITE DURING CONSTRUCTION <br /> PER CBC 3305 . 1 . SHEET: 1 <br />