C.
<br /> KRAZY ROLLS KIOSK NO REV & DATE
<br /> GENERAL PROJECT NOTES:
<br /> 1 . WHERE NEW WORK TIES INTO EXISTING CONTRACTOR SHALL PATCH AND
<br /> REPAIR EXISTING CONSTRUCTION AS REQUIRED TO RESTORE IT TO ITS
<br /> ALBERT VEGA ORIGINAL FINISH , TIE THE NEW WORK INTO EXISTING IN A NEAT AND a
<br /> CRAFTSMAN LIKE MANNER SO THAT NEW BLINDS WITH A SMOOTH AND j
<br /> LEVEL SURFACE INTO ADJACENT WORK . 0 < E
<br /> 2 . ALL NEW WALL FINISHES ( COVERINGS AND PAINTS) SHALL HAVE A FLAME o
<br /> 4950 PACIFIC AVE . on-
<br /> SPREAD RATING OF 25 AOR LESS . F o 06
<br /> 3 . ALL INSULATION MATERIALS , INCLUDING FACINGS , SUCH AS VAPOR BARRIERS Z N
<br /> OR BREATHER PAPERS INSTALLED WITHIN FLOOR - CEILING ASSEMBLIES , at
<br /> STOCKTON , CA 95207 ROOF- CEILING ASSEMBLIES , WALLS , CRAWL SPACES OR ATTICS , SHALL HAVE " o � o �
<br /> A FLAME SPREAD RATING NOT TO EXCEED 25 AND A SMOKE DENSITY NOT W � v (60 -02
<br /> TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH U . B . C . STANDARD NO . - Q
<br /> WEBERSTOWN MALL 4 . W 8 - 1 AND G . B . C . SECTION 707 .
<br /> WHEN INSTALLING DRILLED - IN ANCHORS AND/OR POWDER DRIVEN PINS IN
<br /> EXISTING NON - PRESTRESSED REINFORCED CONCRETE , USE CARE AND
<br /> CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING
<br /> SCOPE OF WORK: GENERAL NOTES : BARS .
<br /> NEW PRE - FRABRICATED KIOSK INSIDE PROJECT SHALL COMPLY WITH FOLLOWING CODES : 5 . ALL WORK SHALL BE DONE IN A NEAT AND WORKMAN LIKE MANNER
<br /> WEBERSTOWN MALL WITH NEW EQUIPMENT; ACCORDING TO THE BEST TRADE PRACTICE BY THOSE SKILLED IN THE
<br /> ELECTRICAL AND PLUMBING . A- 2016 CALIFORNIA BUILDING CODE , PARTICULAR TRADE , EQUIPMENT , FIXTURES , PIPING , ETC . , SHALL BE PLUMB ,
<br /> 13 - 2016 CALIFORNIA MECHANICAL CODE . LEVEL, SQUARE OR CENTERED ETC . , EQUIPMENT TO BE INSTALLED IN LLI
<br /> C - 2016 CALIFORNIA ELECTRICAL CODE , STRICT COMPLIANCE WITH MANUFACTURERS ' RECOMMENDATIONS . 0
<br /> D - 2016 CALIFORNIA PLUMBING CODE . 6 , ALL EXISTING CONDITIONS NOT SHOWN OR INDICATED ON THESE PLANS ARE
<br /> INDEX: E - 2016 CALIFORNIA FIRE CODE . TO REMAIN UNCHANGED , FIELD VERIFY EXISTING CONDITIONS AND ALL
<br /> T . 1 TITLE PAGE F-ALL OTHER CODES ADOPTED BY THE GOVERNING AGENCIES DIMENSIONS . ANY DISCREPANCY BETWEEN DRAWINGS AND ACTUAL WORK W
<br /> A . 0 SITE PLAN HAVING JURISDICTION ON THE PROJECT . SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CORRECTION J
<br /> Mom
<br /> A . 1 FLOOR PLAN G - 2016 CALIFORNIA ENERGY CODE , PRIOR TO COMMENCING WITH THE WORK ,
<br /> A . 2 EQUIPMENT PLAN H - 2016 CALIFORNIA GREEN BUILDING STANDARD CODE . 7 . ALL DIMENSIONS ON THE PLANS ARE TO THE FACES OF STUDS OR ~
<br /> A. 3 ELECTRICAL PLAN I - LOCAL ORDINANCE CENTERED ON COLUMN , A- DOOR AND CASED OPENINGS WITHOUT LOCATION
<br /> A . 4 ELECTRICAL NOTES & 1 - LINE DIAGRAM DIMENSIONS ARE TO BE FOUR ( 4) INCHES FROM FACE OF ADJACENT
<br /> A . 5 PLUMBING PLAN 1 . THE WORD "CONTRACTOR " AS USED HEREIN SHALL MEAN THE PARTITION OR CENTERED BETWEEN PARTITIONS , B - ALIGNMENT TAKE
<br /> A . 6 PLUMBING NOTES & DETAIL GENERAL CONTRACTOR , SUBCONTRACTORS AND ALL PERSONS PRECEDENT OVER DIMENSIONS . VERIFY ALL DIMENSIONS AND CONDITIONSS1p
<br /> DIRECTLY OR INDIRECTLY EMPLOYED BY ANY OF THEM , AND NOTIFY ARCHITECT OF ANY DISCREPANCIES , �p�oNo MpQ9F�Z
<br /> KIOSK PLANS : 2 . CONTRACTOR SHELL COMPLY WITH ALL ORDINANCES , RULES , 8 . THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING UP AND '
<br /> 0 . 0 TITLE PAGE REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AGENCY REMOVING FROM THE JOB SITE ALL TRASH AND DEBRIS IMMEDIATELY UPON Exp 6/JO/2020
<br /> 0 . 1 3D VIEWS HAVING JURISDICTION ON THIS PROJECT AND SHALL NOTIFY COMPLETION OF HIS DAILY WORK .
<br /> 1 . 0 - 1 . 13 KIOSK PLANS OWNER IMMEDIATELY UPON BECOMING AWARE THAT ANY ASPECT 9 , CONSTRUCTION SHALL COMPLY WITH APPLICABLE EDITION OF CALIFORNIA 9 C /V
<br /> 1 . 14 - 1 . 16 TALL SNEEZE GUARD OF THE PROJECT DESCRIBED HEREIN IS AT VARIANCE THERE BUILDING CODE , ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES ,
<br /> 1 . 17 - 1 . 19 SHORT SNEEZE GUARD WITH . ORDINANCES , LAWS , REGULATIONS AND PROTECTIVE COVENANTS GOVERNING MORAD ENGINEERING
<br /> 1 . 20 GATE DETAILS 3 . CONTRACTOR SHALL PROVIDE CERTIFICATES OF INSURANCE THE WORK . IN CASE OF CONFLICT , THE MORE STRINGENT REQUIREMENT EDMOND MORAD. P.E.
<br /> EEr
<br /> 1621 KIOSK CROSS SECTIONS CA9R354
<br /> ACCEPTABLE TO OWNER PRIOR TO COMMENCEMENT OF WORK . SHALL GOVERN . MODESTO,
<br /> 4 . BY SUBMITTAL OF BID CONTRACTOR WARRANTS TO OWNER THAT 10 . CONTRACTOR AND HIS OR HER SUBCONTRACTOR TO HAVE WORKING (los) 530-050
<br /> ALL MATERIALS AND EQUIPMENT TO BE FURNISHED ARE NEW KNOWLEDGE OF ALL CODES APPLICABLE TO THEIR WORK . f`
<br /> BUILDING CODE DATA: Y O
<br /> UNLESS NOTED OTHERWISE AND ALL WORK WILL BE OF GOOD 11 . COORDINATE ALL WORK AND CONSTRUCTION SCHEDULING WITH OWNER . J
<br /> DESCRIPTION OF USE : FOOD KIOSK co Q IN
<br /> OCCUPANCY GROUP : M QUALITY AND FREE FROM FAULTS AND DEFECTS . 12 . THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE BARRICADES ,
<br /> CONSTRUCTION TYPE : VB 5 . CONTRACTOR SHALL VISIT SITE AND VERIFY ALL EXISTING PROTECTIVE COVERINGS , WARNING SIGNS , ETC , TO PREVENT ANY HARM TO 0 W O
<br /> CONDITIONS PRIOR TO SUBMITTAL OF BID . WORKERS , EMPLOYEES AND/OR THE GENERAL PUBLIC . Y Q
<br /> SPRINKLERS : NO Z Q
<br /> STORIES : 1 6 . CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN HEREIN AND 13 . GENERAL CONTRACTOR SHALL MAKE AVAILABLE COMPLETE SETS OF JV 0
<br /> REPORT ALL DISCREPANCIES TO OWNER PRIOR TO SUBMITTAL CONSTRUCTION DOCUMENTS TO HIS OR HER SUBCONTRACTORS FOR REVIEW , J 0 LL Zlot
<br /> OF BID . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE , FOR REVIEWING THE
<br /> 7 . WHERE CONSTRUCTION DETAILS FOR A PART OF THIS PROJECT COMPLETE SETS AND COORDINATING ITEMS WHICH PERTAIN TO HIS OR HER 0 ~ (� 0
<br /> cc ARE NOT SHOWN THE WORK SHALL BE THE SAME AS OTHER WORK WITH OTHER TRADES PRIOR TO COMMENCING WITH THE WORK . ,maw
<br /> SIMILAR WORK FOR WHICH DETAILS ARE SHOWN . 14 . THE CONTRACTOR SHALL PROVIDE MOUNTING PLATES AS REQUIRED BEHIND W I[L
<br /> 8 . FIXTURES , APPLIANCES , FINISHES BRAND NAME AND COLORS NOT ALL WALL MOUNTED ITEMS SUCH AS HANDRAILS , GRAB BARS , TOILET i V
<br /> m 00
<br /> MENTIONED ON THESE PLANS , SHALL BE PER OWNERS CHOICE , PARTITIONS , LIGHT FIXTURES , EQUIPMENT, ETC . IY LLJ LO �
<br /> CONTRACTOR SHALL CONTACT OWNERS PRIOR OF BID , 15 . IT IS NOT INTENDED THAT THE CONTRACT DOCUMENTS INCLUDE EACH AND Y d- (n
<br /> PURCHASE AND INSTALLATION OF SUCH ITEMS . EVERY SUBSYSTEM AND SUB - COMPONENT NECESSARY TO FULLY AND
<br /> 9 , ALL WORK PERFORMED IN THE CONNECTION WITH THESE PROPERLY COMPLETE THE WORK , SUBSYSTEMS , SUB - COMPONENTS OR DATE: 06 - 10 - 19
<br /> CONTRACT DOCUMENTS SHALL COMPLY WITH ALL STATE , LOCAL DETAILS REQUIRED OR NORMALLY INCLUDED AS TRADE PRACTICE MAY NOT DRAWN BY : R . ORTIZ
<br /> CODES AND ORDINANCES IN EFFECT AT THE TIME OF BE SPECIFICALLY MENTIONED OR SHOWN , NEVERTHELESS , CONTRACTOR
<br /> CONSTRUCTION . SHALL BE RESPONSIBLE FOR EACH ELEMENT OF THE WORK . JOB NO:
<br /> 10 . PROVIDE A CHEMICAL TOILET ON SITE DURING CONSTRUCTION
<br /> PER CBC 3305 . 1 . SHEET: 1
<br />
|