INSTALL 2019 TANK TOP UPGRADE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
INSTALL 2019 TANK TOP UPGRADE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/7/2019 11:41:53 AM
Creation date
10/7/2019 9:00:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2019 TANK TOP UPGRADE
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' - ITEM #38 <br /> Submersible T • •s Franklin Fueling - t <br /> Intelligent Submersible Turbine Pump Specifications - <br /> Liquid Compatibility . . • • <br /> • Max.liquid viscosity: 70 SSU at • F�+4 a*C <br /> 60°F (15 'C). <br /> •IST models imply alcohol-gasoline A typical turbine model designation <br /> has u to five components to define <br /> compatibility for fuel mixtures containing p p - <br /> diesel fuel with up to 20%biodiesel,100% the pump being supplied as follows: <br /> biodiesel,up to 85%ethanol with gasoline, IST XXXXX Y - A - B ' • ' <br /> Band 20% MTBE, 20%ETBE or 17% TAME t_ <br /> I with gasoline. IST= Basic Model Designation <br /> •IST models can also be used with diesel Note: All IST models include <br /> fuels,fuel oils, kerosene, Avgas and jet fuels alcohol gasoline compatibility, <br /> in a non-gelled pourable state. ' variable speed and variable <br /> • All wetted elastomers are made of a high length as part of the base model. <br /> grade,fluorocarbon compound. ' <br /> A XXXXX=Factory Installed <br /> »a <br /> Standard Features Options :J- •~ <br /> IST model designations may include `= " <br /> • All IST models include variable one or more of the following _ <br /> speed,variable length options and characters in alphabetical order: <br /> alcohol-gasoline compatibility. <br /> F = Floatinpsuction adapter 1�/2" NP1 <br /> • Check valve:23/4" diameter fluorocarbon female adapter) <br /> P <br /> seal constructed on cast aluminum body Rc� <br /> and steel backing washer, K = Intake filter screen (IFS,factory <br /> • Pressure relief valve:available in four installed to PMA) <br /> M = MagShell'" (flow enhancing, <br /> pressure relief settings,integral to check expanded PMA shell) <br /> For full diagram see Ordering Guide. valve.Standard model relieves at 40 psi and <br /> resets above 35 psi. R' = Model R check valve (24 psi <br /> Power Requirements •Syphon:venturi-type syphon primer relief/22 psi reset for PLLD)W• = Model W check valve 16 si <br /> supplied with every submersible. ( P <br /> IST models can only be powered by a Syphon check valve and secondary relief/13 psi reset for PPM4000) <br /> MagVFC" controller: syphon sold separately. Note:If not otherwise specified,all IST <br /> • 2 hp models can operate with single-or • Air eliminator: every submersible includes models are supplied with <br /> P 9 P supply tank return path with one-way check valve standard model check valve 40 <br /> three-phase incoming ower su I to ( <br /> the Ma VFC' psi relief/35 psi reset for MLD, <br /> 9 to provide active air elimination. TS-LS300,and TS-LS500). <br /> 4 hp models require three-phase incoming • Electrical disconnect:electrical yoke <br /> power supply to the MagVFC' for for positive contractor disconnect Y= Pump Motor Horsepower <br /> proper operation. during service. Rating— <br /> Incoming power supply to the MagVFC" VS4 =4 hp variable speed ' <br /> can be 200-250 V A C, 50 or 60 H z. Approvals -Note:If not otherwise specified,2 hp <br /> • MagVFC" outputs a three-phase,variable • Consult factory for applicable approvals, variable speed is implied. <br /> frequency signal, valid for FE Petro variable <br /> speed pumps only. A= Model Length ' <br /> Quality Certification <br /> •2 hp max. motor draw: 7 Amps. 1 = 2 hp variable length,59"-87" <br /> •4 hp max. motor draw: 15 Amps. Franklin Fueling Systems is an ISO 9001 Certified Manufacturer. 2= 2 hp variable length,90%151" <br /> • MagVFC- max.line draw:20 Amps. 3 = 2 hp variable length,122"-213" ' <br /> UL1 = 4 hp variable length,64"-92" <br /> Pump Motor VL2 = 4 hp variable length,95"-156" <br /> • 2 hp or 4 hp,variable speed,two-stage (; U� US LISTED VL3 = 4 hp variable length,127"-218" <br /> centrifugal type pump motor with integral, Note:IST-2 and ISTVS4-VL2 models fit ' <br /> automatic,thermal overload protection. 94%of all known installations. <br /> • Max.flow:2 hp = 110 gpm,4 hp = 140 gpm. B= Riser Pipe Length <br /> • Max.pressure:selectable operating Riser pipe length is expressed as two ' <br /> pressure on MagVFC' between 24 psi and numeric characters that indicate the <br /> 42 psi deadhead. total length of the riser in inches. Riser <br /> • Available with MagShell",which results in pipes are available from 7"to 69" in <br /> 45%increased flow area around motor. 1"increments(additional charge for ' <br /> risers 31" or longer). <br /> 16 ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.