Laserfiche WebLink
Covey Auto Express Inc. Stockton,CA <br /> 1444 EI Pinal Dr. <br /> Stockton,CA 95205 <br /> 500 GA Waste Oil Aboveground Storage Tank <br /> TANK ASSESSMENT WASTE OIL HOLDING AST Waste AST k 2 <br /> January 21,2014 Inspection <br /> This assessment is for a 500 GA Single Wall Steel Horizontal Cylindrical AST containing Waste Oil <br /> located in the site's southwest corner of Covey Auto Express Inc. Stockton,CA. The facility services <br /> truck vehicles including draining and replacing motor oil. Due to business volume they are classified as a <br /> "Large Quantity Generator". <br /> Tank inspection was by Daniel K. Barber, RCE California and Certified Steel Tank Institute Inspector. <br /> Owner Contact: Mike Covey Jr.,Covey Auto Express Inc. (209)464-0016 <br /> CONTAINMENT ASSESSMENT <br /> The single wall steel AST is located within a concrete block walled basin on PCC concrete pavement. <br /> There is no attached UL Tag.The manufacturer's label indicates The AST was manufactured in Portland, <br /> Oregon by King Bros.The steel shell measures 0.098 to 0.105 IN thick,66 IN long and 48 IN diameter. <br /> There is a large 2 SF dent in the underside of the shell although no leakage,sharp break, nor decrease in <br /> wall thickness is apparent. <br /> The block wall containment(10.75'x13.42'x2.79')capacity,3,011 GA less 2.7"precipitation from a 25 <br /> year 24 hr.storm event allowance of 243 GA, is 2,768 GA.Assuming the contained ASTs are @500 GA,& <br /> 2 @275 GA or a total of 1,050 GA,there is ample capacity. <br /> The PCC floor has several construction joints and they should be sealed to provide an effective barrier to <br /> contain waste oil. Drain 1-Y IN coupling at northeast corner should be closed with valve and plug or lock. <br /> The subject waste oil AST is blocked with several wooden timbers and neither secured nor elevated <br /> above the concrete floor. Leakage is not apparent. <br /> Collected waste oil is transferred to the AST through a single 2 IN threaded(NPT)hole in the top of AST. <br /> There is no method to prevent overfilling in the event of operator in-attention, however,the quantities <br /> transferred are defined and periodic.With an awareness of the tank's waste oil level,the transfers do <br /> not threaten over filling between reclamation pickups. Record of pickup by Asbury Environmental <br /> Service is current and affixed to the AST. <br /> Details of the AST external inspection are attached. No venting is on the AST,aside from the single open <br /> port. <br /> Daily observations for visible signs of leakage are to be recorded by Covey Auto Express Inc. staff. <br /> Records are to be maintained on the site for 3 years. Drainage of containment must be witnessed and <br /> recorded. <br />