COMPLIANCE INFO 2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4747
>
2300 - Underground Storage Tank Program
>
PR0232482
>
COMPLIANCE INFO 2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2019 3:44:53 PM
Creation date
10/9/2019 1:31:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232482
PE
2361
FACILITY_ID
FA0003719
FACILITY_NAME
WEST LANE CHEVRON
STREET_NUMBER
4747
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437010
CURRENT_STATUS
01
SITE_LOCATION
4747 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a 3:VFM 5-6 <br /> IN-TANK DIAGNOSTIC: AIR FLOW METER `-,, F ISD DAILY REPORT <br /> - - - - - - - - - -- - - SERIAL NUMBER 9265 <br /> PROBE DIAGNOSTICS <br /> T 3: PROBE TYPE MAGI CHEVRON 200764 <br /> SERIAL NUMBER 365664 4747 WEST LANE <br /> LENGTH 120.00 5 4:VFM 7-8 <br /> DATE CODE = 12676 209-956--2520_9521G <br /> ID CHA(+J = OxC000 AIk�FLUW METER <br /> GRADIENT = 350.4200 SERIAL NUMBER 25031 SEP 29, 2- <br /> ' U16 9:04 hhl <br /> PROBE INIT: <br /> JUL 11 .2016 11 :47PM <br /> s 5:PRESSURE DI SP 1-2ISVBALANCE NUM SAMPLES 20 EVR TYPE: <br /> VAPOR PRESSURE VAPOR PROCESSOR <br /> TYPE <br /> iC00 1404'.0 C01 22330.4 SERIAL NUMBER 6090 VEEDER-ROOT POLISHER <br /> CO2 22'330.4 CO3 22330.1 <br /> C04 22330.0 C05 22329.7 REPORT DATE: SEP 28 <br /> C06 22341 .8 -CC17 22841 .4 ISD VERSION 01 .02 <br /> COB 22341 ..8 C09 22341 .3 <br /> CIO 29341 .4 C11 42724.0 s 6:V-R POLISHER OVERALL STATUS PASS <br /> C12 13638.0 C13 14201 .8 'VAPOR HALVE EVR CONTAINMENT PASS <br /> C14 14905.8 C15 15736.3 SERIAL NUMBER 10090003 EVR COLLECTION PASS <br /> C16 15907.3 C17 16095.3 VALVE POSITION: OPEN STAGEI I of I PA . : <br /> C18 42725.1 OPEN CAP: CHARGED VAPOR PROCESSOR PASS <br /> SAMPLES READ =26067072 CLOSE CAP: CHARGED SELF TEST PIIS <br /> SAMPLES USED =26050695 AMBNT TEMP: 69.66 F ISD MONITOR UP-TIME 100% <br /> LAST ERROR =26041931 OUTLET AU 68.50 F <br /> F -------_ <br /> LAST SAMPLE ERROR TIME: SENSOR FAULTS: CONTAINMENT TESTS <br /> SEP 29,2016 12:46AM NONE <br /> ➢GROSS 95% -0.0 "WC <br /> TEMP SENSOR DATA DGRD 75 -0.5 "WC <br /> T6: 82.242 F VAPOR LEAK. <br /> T5: 80.889 FMAX 10 CFH <br /> s 8:ATM P SENSOR MIN 2.8 "WC <br /> T4: 79.218 F <br /> T3: 77.'272 F -3.8 "WC; <br /> AT <br /> T2: 76.876 ATMP SENSOR <br /> SERIAL NUMBER 3061 <br /> T1 : 76.440 F <br /> ATM PRESSURE 0.018 PSI --- <br /> ---------. <br /> COLLECTION TESTS <br /> ORIG REF DISTANCE GROSS <br /> SEP 29, 2015 127.77 V/L(#) <br /> CURR.REF DISTANCE <br /> SEP 28, 2016 127.77 FP 1 : BLENDS <br /> V/L = 1 .03( 60) <br /> FP : BLEND3 <br /> V/L = 0.97( 45) <br /> FP 3: BLENDS <br /> V/L = 1 .06( 57) <br /> FP 4: BLEND3 <br /> V 'L = 0.92( 54) <br /> FP 5: BLENDS <br /> SMARTSENSOR DIAGNOSTIC V/L = 0.91 ( 90) <br /> FP 6: BLENDS <br /> - - - - - - - - - - - - PMC DIAGNOSTIC V/L '= 0.91 ( 39) <br /> SEP 29, 2016 9:03 AM FP 7: BLENDS <br /> V,,, <br /> PMC VERSION: 01 .0'2 L = 0.84( 49) <br /> FP 8BLEND3 <br /> s 1 :VFI°1 1 <br /> VAPOR PRESSURE V/L = 1 .07( 23) <br /> INCHES H20: -0.644 <br /> AIR FLOW h1ETER ------ ---¢-- <br /> VEEDER-ROOT POLISHER PROCESSOR TESTS <br /> SERIAL NUMBER 24965 <br /> LOAD: 1 .8%4 VP OVER PRESSURE TEST <br /> VAPOR PROCESSOR MODE STATUS -0.36"WC PASS <br /> s 2:VFM 3-4 MANUAL VP STATUS TEST <br /> AIR FLOW METER VAPOR VALVE POSITION STATUS NOTEST <br /> SERIAL NUMBER 24958 CURRENT : OPEN <br /> REQUESTED: CLOSED <br /> TEIP: 68.62 DEG F ------------•---- <br /> SELF TEST <br /> SETUP TEST PASS <br /> SENSOR OUT -TEST PASS <br />