Laserfiche WebLink
Z <br />J <br />a <br />a <br />Co <br />Z <br />J <br />w <br />J <br />Q <br />Co <br />LU <br />Z <br />J <br />w <br />IL <br />Co <br />CONSTRUCTION NOTES: <br />1. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR METHODS OF <br />CONSTRUCTION, WORKMANSHIP, AND JOB SAFETY. WORKMANSHIP AND <br />MATERIALS INCLUDING FALSEWORK, BRACINGS, AND OTHER TEMPORARY ITEMS <br />SHALL CONFORM TO THE GOVERNING CODES AND JOB SAFETY REQUIREMENTS <br />PER OSHA STANDARDS. <br />2. CONSTRUCTION SAFETY PROVISIONS IN ACCORDANCE WITH THE BUILDING CODE <br />SHALL BE PROVIDED AND APPROVED BY THE BUILDING INSPECTOR PRIOR TO <br />STARTING ANY WORK ON THE BUILDING. PERMITS FOR PROTECTIVE FENCES AND <br />/OR CANOPIES CONSTRUCTED ON PUBLIC PROPERTY MUST BE SECURED FROM <br />THE DEPARTMENT OF BUILDING AND SAFETY. <br />3. CONSTRUCTION, INSPECTION AND PHYSICAL TESTING PROCEDURES SHALL <br />CONFORM TO THE REQUIREMENTS OF THE GOVERNING CODES AND THE <br />AMENDMENTS BY THE LOCAL JURISDICTION. <br />4. CONSTRUCTION LOADING SHALL NOT EXCEED THE DESIGN LIVE LOAD UNLESS <br />SPECIAL SHORING IS PROVIDED. ALLOWABLE LOADS SHALL BE REDUCED IN <br />AREAS WHERE THE STRUCTURE HAS NOT ATTAINED ITS FULL DESIGN STRENGTH. <br />5. THE CONTRACTOR SHALL PROVIDE A LEVEL TOP SURFACE FOR ALL SLABS IN <br />ACCORDANCE WITH THE LEVELNESS TOLERANCE REQUIRED FOR ALL FINISHES, <br />PARTITIONS, BUILT-IN CABINETS AND COUNTERS, ETC. THE CONTRACTOR SHALL <br />ADJUST ALL BEAM SIDE FORMS TO ALLOW FOR AS -DELIVERED CAMBERS OF <br />STEEL MEMBERS AND TO MAINTAIN THE MINIMUM DEPTH OF CONCRETE <br />SLAB/TOPPING AT MIDSPAN OF THE STEEL MEMBERS. <br />6. PROVIDE NON -SLIP FINISH ON ALL CONCRETE STAIR TREADS, EXPOSED <br />FLATWORK, AND WHERE SPECIFIED ON WORKING DRAWINGS. <br />7. ANY SUPPORT SERVICES PERFORMED BY THE ENGINEER DURING <br />CONSTRUCTION SHALL BE DISTINGUISHED FROM CONTINUOUS AND DETAILED <br />INSPECTION SERVICES WHICH ARE FURNISHED BY OTHERS. THESE SUPPORT <br />SERVICES WHICH ARE FURNISHED BY THE ENGINEER, WHETHER OF MATERIAL <br />OR WORK, AND WHETHER PERFORMED PRIOR TO, DURING OR AFTER <br />COMPLETION OF CONSTRUCTION, ARE PERFORMED SOLELY FOR THE PURPOSE <br />OF ASSISTING IN QUALITY CONTROL AND IN ACHIEVING CONFORMANCE WITH <br />CONTRACT DRAWINGS AND SPECIFICATIONS, BUT THEY DO NOT GUARANTEE <br />CONTRACTORS PERFORMANCE AND SHALL NOT BE CONSTRUED AS <br />SUPERVISION OF CONSTRUCTION. <br />8. WHERE PUBLIC UTILITY LINES OR EQUIPMENT MUST BE REMOVED AND <br />RELOCATED, OBTAIN THE NECESSARY APPROVALS PRIOR TO STARTING <br />CONSTRUCTION FROM THE RESPECTIVE UTILITY AGENCIES. <br />9. CONTROL JOINTS SHALL BE INSTALLED IN SLAB ON GRADES SO THE SLAB'S <br />LENGTH TO WIDTH RATIO IS NOT MORE THAN 1.25:1. CONTROL JOINTS SHALL BE <br />COMPLETED WITHIN 12 HOURS OF CONCRETE PLACEMENT AND THE JOINT DEPTH <br />SHALL BE 1/4 OF THE SLAB THICKNESS. <br />10. A SEPARATE PERMIT MUST BE SECURED FOR ALL ELECTRICAL, PLUMBING, AND <br />HEATING -VENTILATING WORK. <br />11. CONTRACTOR SHALL PROVIDE A COPY OF SHORING PLANS TO THE ENGINEER <br />FOR APPROVAL. <br />DRAWING NOTES: <br />1. ALL DETAILS, SECTIONS, AND NOTES ON DRAWINGS ARE INTENDED TO BE <br />TYPICAL AND SHALL APPLY TO SIMILAR SITUATIONS, U.N.O. <br />2. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER THESE <br />GENERAL SPECIFICATIONS. DIMENSIONS FOR CONSTRUCTION SHALL NOT BE <br />SCALED FROM THE DRAWINGS <br />3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE <br />CONDITIONS BEFORE COMMENCING WORK. WHERE ACTUAL CONDITIONS <br />CONFLICT WITH THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR <br />SPECIFICATIONS, DISCREPANCIES OR OMISSIONS SHALL BE REPORTED TO THE <br />ENGINEER OF RECORD PRIOR TO PROCEEDING WITH CONSTRUCTION. <br />4. THE CONTRACTOR SHALL ALLOW REASONABLE TIME FOR THE ENGINEER OF <br />RECORD TO RESOLVE CONFLICTS AND/OR MAKE REVISIONS TO THE DRAWINGS <br />AND/OR SPECIFICATIONS. REVISIONS TO THE DRAWINGS SHALL BE REVIEWED <br />AND APPROVED BY THE BUILDING OFFICIAL. <br />5. THE DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE, <br />UNLESS OTHERWISE SHOWN, THEY DO NOT INDICATE THE METHOD OF <br />CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK <br />AND HE SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, <br />METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. <br />6. THE STAMPED SET OF DRAWINGS AND SPECIFICATIONS SHALL BE KEPT AT THE <br />JOB SITES AND SHALL BE AVAILABLE TO THE AUTHORIZED REPRESENTATIVES OF <br />THE BUILDING AND SAFETY DEPARTMENT. THERE SHALL BE NO DEVIATION FROM <br />THE APPROVED PLANS AND SPECIFICATIONS WITHOUT AN APPROVED CHANGE <br />ORDER. <br />1. UNLESS A SOILS REPORT AND SOIL PROPERTIES ARE REFERENCED BELOW, THE <br />SUBSURFACE CONDITIONS WERE ASSUMED TO BE NON -EXPANSIVE CLAY AND <br />THE CORRESPONDING ALLOWABLE DESIGN VALUES WERE ASSUMED TO BE <br />THOSE STATED IN THE GOVERNING CODE: <br />- SOILS REPORT NOT AVAILABLE <br />- SOIL: BEARING VALUE = 1500 PSF. <br />2. THE SOILS REPORT AND LOG OF BORINGS WERE OBTAINED BY THE OWNER FOR <br />THE ENGINEER'S USE IN THE DESIGN OF THE FOUNDATION AND IS NOT A PART OF <br />THE CONTRACT DOCUMENTS. THIS REPORT AND LOG OF BORINGS IS AVAILABLE <br />FOR THE CONTRACTOR'S INFORMATION, BUT IS NOT A WARRANTY OF THE <br />SUBSURFACE CONDITIONS. THE CONTRACTOR MAY USE THE REPORT AT HIS <br />OWN RISK: <br />3. FOOTINGS SHALL BEAR A MINIMUM 12" BELOW ADJACENT GRADE OR <br />CONTROLLED COMPACTION OR AS NOTED ON THE PLANS. EXCAVATIONS FOR <br />THE FOOTINGS SHALL BE FREE OF WATER PRIOR TO PLACING OF CONCRETE. <br />ALL BACKFILL SHALL BE COMPACTED TO A MINIMUM OF 900 OF MAXIMUM <br />DENSITY. <br />4. NO PERSON SHALL DESCEND INTO TRENCHES OR EXCAVATIONS WITH A DEPTH <br />GREATER THAN 5 FEET, UNLESS NECESSARY PERMITS HAVE BEEN OBTAINED <br />FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY. <br />5. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION <br />PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF ANY <br />ADJACENT PROPERTY, STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE <br />WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. <br />6. CONTRACTOR SHALL REVIEW EXISTING UTILITY PLANS AND SHALL VERIFY THE <br />LOCATION OF ALL UTILITY LINES IN THE AREA TO BE EXCAVATED PRIOR TO <br />EXCAVATION FOR NEW FOUNDATIONS. <br />7. EMBED ANCHOR BOLTS INTO CONCRETE AS SHOWN ON THE DRAWINGS. PLACE <br />ONE ANCHOR BOLT WITHIN 12 INCHES OF EACH CORNER OR PLATE SPLICE. <br />MINIMUM BOLTING SHALL BE 5/8" DIAMETER AT 4'-0" W/ 9"MIN. EMBEDMENT INTO <br />CONCRETE. <br />1. 1. CONCRETE MIXES SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR <br />APPROVAL. MATERIAL SHALL BE PROPORTIONED TO PRODUCE CONCRETE WITH <br />THE FOLLOWING MINIMUM <br />COMPRESSIVE STRENGTHS AT 28 DAYS, U.N.O: <br />1.1. STRUCTURAL SLABS: 3000 PSI <br />1.2. GRADE BEAMS: 3000 PSI <br />1.3. ISOLATED PADS: 2500 PSI <br />1.4. CONTINUOUS FOOTINGS: 2500 PSI <br />1.5. SLAB ON GRADE: 2500 PSI <br />1.6. ALL OTHERS: 2500 PSI <br />NOTE: CONTINUOUS INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED FOR ALL <br />CONCRETE DESIGNED WITH FC GREATER THAN 2500 P.S.I. <br />2. NORMAL WEIGHT CONCRETE SHALL BE 145 TO 155 POUNDS PER CUBIC FOOT. <br />LIGHTWEIGHT CONCRETE SHALL BE IN ACCORDANCE WITH THE APPROVED <br />DESIGN MIX SHOWN ON THE PLANS. <br />3. CEMENT SHALL CONFORM TO ASTM C150, TYPE II CEMENT. FINE AND COARSE <br />AGGREGATE SHALL CONFORM TO ASTM C33. WHEN SPECIFIED, AIR -ENTRAINING <br />ADMIXTURES SHALL COMPLY WITH ASTM C260. READY MIX CONCRETE SHALL BE <br />MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C94. <br />4. MAXIMUM SIZE OF COURSE AGGREGATE FOR SLABS SHALL BE 1" AND 1'/2" <br />ELSEWHERE, U.N.O. SAND SHALL BE CLEAN, HARD, DURABLE, WASHED, FREE <br />FROM SILT, LIME OR CLAY. MIXING WATER SHALL BE CLEAN AND FREE FROM <br />INJURIOUS AMOUNTS OF OIL, ACIDS, ALKALIS, ORGANIC MATERIALS OR OTHER <br />DELETERIOUS SUBSTANCES. CONCRETE MIX MAY CONTAIN A POLYMER BASED <br />WATER REDUCING ADMIXTURE. THE MAXIMUM SLUMP OF CONCRETE SHALL NOT <br />EXCEED 6" UNLESS OTHERWISE APPROVED BY THE ENGINEER. <br />5. CEMENT TYPES SHALL NOT BE MIXED IN THE CONCRETE MIX. CALCIUM <br />CHLORIDE OR FLY ASH SHALL NOT BE USED IN THE CONCRETE MIX. <br />6. FORMWORK SHALL COMPLY WITH STANDARD PUBLICATION (ACI 347) AND THE <br />PROJECT SPECIFICATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE <br />DESIGN, DETAILING, CARE, PLACEMENT AND REMOVAL OF THE FORMWORK AND <br />SHORES. <br />7. PIPES, DUCTS, SLEEVES, CHASES, ETC. SHALL NOT BE PLACED IN SLABS, BEAMS, <br />OR WALLS UNLESS SPECIFICALLY SHOWN OR NOTED ON PLANS. CONTRACTOR <br />SHALL OBTAIN APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, <br />ETC. REFER TO ARCHITECTURAL AND MECHANICAL PLANS FOR LOCATIONS OF <br />ALL PIPES, DUCTS, CHASES, ETC. ALL SUSPENDED EQUIPMENT TO BE PROVIDED <br />WITH CBC/IBC APPROVED LATERAL OR SWAY BRACING. <br />REINFORCING STEEL: <br />1. REINFORCING STEEL SHALL CONFORM TO ASTM 615, GRADE 60, U.N.O. STEEL <br />BARS SHALL BE DEFORMED BARS THAT ARE FREE FROM GREASE, RUST, MILL <br />SCALE OR ANY OTHER FOREIGN MATERIAL WHICH MAY AFFECT THE BARS <br />ABILITY TO BOND TO THE CONCRETE. REINFORCING STEEL SHALL HAVE MINIMUM <br />PROTECTIVE COVER AS FOLLOWS: <br />1.1. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" <br />1.2. CONCRETE EXPOSED TO EARTH OR WEATHER, 6 THRU 11 BARS 2" <br />1.3. CONCRETE NOT EXPOSED TO WEATHER NOR IN CONTACT WITH GROUND <br />1 '/2" <br />1.4. CONCRETE FOR SLABS, WALLS AND JOISTS, 11 BARS AND SMALLER 3/4" <br />1.5. CONCRETE FOR BEAMS AND COLUMNS, INCLUDING TIES, STIRRUPS, AND <br />SPIRALS 1 '/2" <br />1.6. MASONRY WALLS, PILASTER AND LINTELS REINFORCEMENT 11/211 <br />2. ALL DETAILING OF REINFORCING SHALL CONFORM TO THE REQUIREMENTS OF <br />ACI 318-11. ALL REINFORCING BAR BENDS SHALL BE MADE COLD. <br />REINFORCEMENT THAT IS PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE <br />FIELD BENT, U.N.O. <br />3. CONTRACTOR SHALL USE CHAIRS OR OTHER SUPPORT DEVICES RECOMMENDED <br />BY THE CRSI TO SUPPORT THE REINFORCING BARS OR WELDED WIRE MESH <br />PRIOR TO PLACING CONCRETE. WELDED WIRE MESH SHALL BE CONTINUOUSLY <br />SUPPORTED AT 36" O.0 MAXIMUM. <br />4. LAP SPLICES SHALL HAVE A MINIMUM LENGTH OF 24" OR 40 BAR DIAMETERS FOR <br />MASONRY AND 12" OR 36 BAR DIAMETERS FOR CONCRETE, U.N.O. <br />5. REINFORCING STEEL, ANCHOR BOLTS, DOWELS, AND WALL TIES SHALL BE <br />SECURED IN POSITION AND INSPECTED BY THE LOCAL BUILDING INSPECTOR <br />PRIOR TO POURING OF ANY CONCRETE OR GROUTING MASONRY. <br />6. REINFORCEMENT TO BE WELDED TO STEEL MEMBERS SHALL CONFORM TO ASTM <br />706 AND SHALL REQUIRE CONTINUOUS INSPECTION. <br />1. CONCRETE BLOCK: SHALL BE HOLLOW LOAD BEARING MASONRY UNITS <br />CONFORMING TO ASTM C-90 GRADE N, TYPE I, MEDIUM WEIGHT, GRAY. F'M=1500 <br />PSI. A LETTER OF CERTIFICATION FROM THE SUPPLIER SHALL BE REQUIRED AT <br />TIME OF, OR PRIOR TO DELIVERY OF MATERIALS. <br />2. MORTAR AND GROUT: TO BE TYPE "S" MORTAR TO BE 1 PART CEMENT, 3-1/2 <br />PART SAND, 1/4 PART LIME PUTTY. <br />3. PEA GRAVEL CONCRETE GROUT TO BE: 1 PART CEMENT, 3-1/2 PART SAND, 1/4 <br />PART LIME PUTTY <br />4. GROUT POUR SHALL BE LIMITED TO 6" AT WORK STOPPAGES: HORIZONTAL <br />CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING GROUT 1-1/2" BELOW <br />TOP OF MASONRY. GROUT SHALL BE TAMPED TO ASSURE FILLING OF ALL VOIDS. <br />5. DRY PACK SHALL BE 1:2 STIFF MIX. <br />6. BED JOINTS TO BE FULLY BEDDING HEAD MORTAR. HEAD JOINTS TO BE SOLIDLY <br />FILLED AT LEAST 1-1/2" FROM EACH FACE. <br />7. REINFORCEMENT SHALL BE SECURED AGAINST DISPLACEMENT PRIOR TO <br />GROUTING, USING WIRE POSITIONERS (OR SUITABLE DEVICES) AT INTERVALS <br />NOT EXCEEDING 200 BAR DIAMETERS. <br />8. CLEANOUTS SHALL BE PROVIDED FOR ALL GROUT POURS OVER 5'. <br />9. ALL CELLS AND SPACES CONTAINING REINFORCEMENT SHALL BE FILLED WITH <br />GROUT. <br />10. FIVE MASONRY PRISM TESTS SHALL BE BUILT AND TESTED PRIOR TO <br />CONSTRUCTION. <br />11. JOINT REINFORCEMENT USED IN EXTERIOR WALLS SHALL BE HOT DIPPED <br />GALVANIZED <br />12. DEPUTY INSPECTION IS REQUIRED. <br />LOS ANGELES RESEARCH REPORT: <br />1. FRAMING CLIPS: LARR 25716, 25814 <br />2. SHEAR PLATES: LARR 25074 <br />3. HOLDOWNS: LARR 25720, 25828 <br />4. RETROFIT ANCHOR BOLTS: LARR 24682 <br />5. JOIST HANGERS: LARR 25800, 25807 <br />6. STRAPS: LARR 25713 <br />7. PSL BEAMS: LARR 25202 <br />8. SIMPSON SET -XP EPDXY: LARR25744 <br />9. HARDY FRAME: LARR25759 <br />STRUCTURALSTEEL <br />1. ALL STRUCTURAL STEEL WORK SHALL BE IN ACCORDANCE WITH THE A.I.S.C. <br />SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF <br />STRUCTURAL STEEL FOR BUILDINGS. <br />2. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING: <br />SHAPES ASTM A-36 <br />PLATES AND BARS A.S.T.M. A-36 <br />MACHINE BOLTS A.S.T.M. A-307 <br />ANCHOR BOLTS & PINS A.S.T.M. A-307 <br />AND/OR A325 <br />PIPE A.S.T.M. A-53 <br />GRADE B <br />STRUCTURAL TUBES A.S.T.M. A-500 KSI <br />GRADE B FY=46 <br />3. LICENSED FABRICATORS APPROVED BY THE BUILDING DEPARTMENT SHALL <br />FURNISH SHOP DRAWINGS FOR REVIEW BY THE STRUCTURAL ENGINEER PRIOR <br />TO FABRICATION OF STRUCTURAL MEMBERS. <br />4. ALL CONNECTIONS NOT DETAILED ON THE PLANS SHALL BE DETAILED BY THE <br />STEEL FABRICATOR AND SHALL BE SHOWN ON THE SHOP DRAWINGS <br />SUBMITTED TO THE ENGINEER FOR REVIEW. <br />5. HOLES FOR BOLTS IN STRUCTURAL STEEL SHALL BE DRILLED OR PUNCHED. <br />BURNING OF HOLES SHALL NOT BE PERMITTED. <br />6. ALL STRUCTURAL STEEL SHAPES SHALL BE PRIMED WITH A RUST RESISTANT <br />PRIMER BEFORE SHIPMENT TO THE PROJECT SITE. <br />7. AFTER ERECTION IS COMPLETE, TOUCH-UP ALL SHOP PRIMING COATS <br />DAMAGED DURING TRANSPORTATION AND ERECTION. <br />8. THE USE OF HIGH-STRENGTH A 325 AND A 490 BOLTS SHALL BE IN ACCORDANCE <br />WITH THE REQUIREMENTS OF U.B.C. CHAPTER 22, DIVISION IV. <br />STRUCTURAL LUMBER <br />1. ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR COAST REGION AND SHALL <br />BE IDENTIFIED AS REQUIRED BY PS 20-70 BY A GRADE MARK OF A LUMBER <br />GRADING AGENCY APPROVED BY THE BOARD OF REVIEW OF THE AMERICAN <br />LUMBER STANDARDS COMMITTEE. <br />2. ALL FRAMING MEMBERS SHALL BE AS FOLLOWS EXCEPT AS NOTED. <br />4X OR 2X <br />DFL NO.1 Fb=1000 PSI, Fv=95 PSI, E=1700 KSI <br />DFL NO.2 Fb=900 PSI, Fv=95 PSI, E=1600 KSI <br />6X AND LARGER <br />DFL NO.1 Fb=1350 PSI, Fv=85 PSI, E=1600 KSI <br />SELECT STRUCT. Fb=1600 PSI, Fv=85 PSI, E=1600 KSI <br />PARALLAM (PSL) Fb=2900 PSI, Fv=290 PSI, E=2000 KSI <br />MICROLLAM (LVL) Fb=2600 PSI, Fv=285 PSI, E=1900 KSI <br />3. SILL PLATES IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE <br />TREATED DOUGLAS FIR. <br />4. FRAMING ANCHORS, HANGERS, STRAPS, COLUMN CAPS AND BASES AND <br />HOLDOWNS SHOWN ARE AS MANUFACTURED BY SIMPSON COMPANY, BREA, CA <br />DESIGNATIONS SHOWN ON THE DRAWINGS ARE FROM SIMPSON CATALOGUE <br />C-98 OR LATEST EDITION. FILL ALL ROUND AND TRIANGLE NAIL HOLES WITH <br />NAILS TYPICAL. CONNECTORS USED OTHER THAN SIMPSON STRONG -TIE <br />PRODUCTS SHALL BE AT THE RISK OF THE CONTRACTOR. DMAC ENGINEERING, <br />INC. DOES NOT ACCEPT ANY RESPONSIBILITY NOR GUARANTEE THAT OTHER <br />CONNECTORS ARE EQUIVALENT IN ALL RESPECTS INCLUDING LOAD CAPACITY, <br />QUALITY AND/OR PERFORMANCE TO SIMPSON STRONG -TIE PRODUCTS. <br />5. PLYWOOD SHALL BE 3/8" CDX UNLESS NOTED OTHERWISE AND SHALL <br />CONFORM TO THE STANDARDS IN PS 1-74 OR PS 1-83. ALL PANELS TO BE <br />IDENTIFIED WITH A GRADE MARK OF AN APPROVED TESTING AND GRADING <br />AGENCY. EXTERIOR GLUE SHALL BE USED. NAILING OF PLYWOOD SHALL BE <br />APPROVED PRIOR TO COVERING PLYWOOD. <br />6. ALL WALLS NOT SOLIDLY SHEATHED OR CONTAINING SHEAR PANELS SHALL <br />HAVE A 1x6 DIAGONAL LET -IN OR APPROVED STEEL X BRACE AT THE ENDS AND <br />AT NOT MORE THAN 25' ON CENTER. BRACE SHALL EXTEND FROM BOTTOM OF <br />LOWEST PLATE TO TOP OF UPPER PLATE. <br />7. ALL STUD PARTITIONS OR WALLS OVER TEN FEET IN HEIGHT SHALL HAVE 2x <br />BRIDGING, SAME WIDTH AS STUDS, PREFERABLY AT MID -HEIGHT BUT NOT TO <br />EXCEED 8' VERTICAL INTERVAL. <br />8. DO NOT NOTCH JOISTS, RAFTERS OR BEAMS EXCEPT WHERE SHOWN ON THE <br />DETAILS. HOLES THROUGH SILLS, PLATES, STUDS AND DOUBLE PLATES IN <br />WALLS SHALL NOT EXCEED 1/3 OF THE PLATE WIDTH. USE BORED HOLES <br />LOCATED IN CENTER OF MEMBER OR USE METAL STRAP ON NEAR SIDE. NO <br />HOLES PERMITTED IN STUDS, SILL PLATES OR TOP PLATES OF SHEAR PANELS <br />WITHOUT EXPRESSED APPROVAL. <br />9. PROVIDE APPROVED X BRIDGING OR SOLID BLOCKING FOR BEAMS, RAFTERS <br />AND JOISTS OF MORE THAN EIGHT INCHES DEPTH AT NOT MORE THAN EIGHT <br />FEET ON CENTER. <br />10. BOLTS IN WOOD SHALL BE NOT LESS THAN 7 BOLT DIAMETERS FROM ENDS AND <br />4 BOLT DIAMETERS FROM EDGES UNLESS NOTED. BOLT HOLES SHALL BE 1/32" <br />LARGER IN DIAMETER THAN THE BOLT SIZE <br />11. LAG BOLTS SHALL HAVE LEAD HOLES BORED. HOLE DIAMETER TO BE: <br />A. SHANK PORTION: SAME DIAMETER AND LENGTH AS SHANK. <br />B. THREADED PORTION: 0.6-0.75 TIMES DIAMETER OF THREAD. <br />12. HOLES FOR NAILS, WHERE NECESSARY TO PREVENT SPLITTING SHALL BE <br />PREDRILLED AT A SMALLER DIAMETER THAN NAIL. <br />13. EXPOSED EXTERIOR NAILS AND HARDWARE SHALL BE GALVANIZED. <br />14. USE MALLEABLE IRON WASHERS UNDER EXPOSED EXTERIOR BOLT HEADS AND <br />NUTS. MALLEABLE WASHERS TO HAVE A DIAMETER 4 TIMES BOLT DIAMETER <br />AND THICKNESS 1/2 BOLT DIAMETER. <br />15. DOUBLE TOP PLATES AT ALL EXTERIOR WALLS AND ALL BEARING PARTITIONS <br />(NOT OTHERWISE DETAILED) SHALL LAP 4'4" MINIMUM AT SPLICES AND SHALL <br />HAVE 6-16d NAILS MINIMUM THROUGH EACH SIDE OF SPLICE IN PLATES. <br />16. SPECIALLY DESIGNED TOP PLATE SPLICE NAILING SHALL BE MADE WITHIN 3'-0" <br />OF SPLICE JOINT. <br />17. WALL FRAMING CONSTRUCTION SHALL CONFORM WITH SECTION 2308.9 CBC <br />2016. <br />18. PLATE WASHER FOR ALL ANCHOR BOLTS TYPICAL: <br />BOLT <br />SIZE <br />STEEL <br />SQUARE (A-36) <br />MIN. EDGE <br />DISTANCE <br />5/8" <br />3 x 3 x 1/4 <br />1 7/8" <br />3/4" <br />3 x 3 x 1/4 <br />2 1/2" <br />7/8" <br />3 1/2 x 3 1/2 x 5/16 <br />2 5/8" <br />S1..................................................................................0.331 <br />4 x 4 x 3/8 <br />3 3/4" <br />NOTE: <br />APPROVE PLATE WASHERS TO BE USED <br />FOR PLYWOOD SHEARWALL SILL PLATE <br />ANCHOR BOLTS AND FOR HOLDOWN <br />CONNECTOR BOLTS AT SHEARWALLS. <br />FOR WOOD TO WOOD OR WOOD TO STEEL <br />CONNECTION. <br />STRUCTURAL OBSERVATION (GENERAL): <br />1. STRUCTURAL OBSERVATION IS THE VISUAL OBSERVATION OF THE ELEMENTS <br />AND CONNECTIONS OF THE STRUCTURAL SYSTEM AT SIGNIFICANT <br />CONSTRUCTION STAGES AND THE COMPLETED STRUCTURE FOR GENERAL <br />CONFORMANCE TO THE APPROVED PLANS AND SPECIFICATIONS. <br />2. THE OWNER SHALL EMPLOY THE ENGINEER RESPONSIBLE FOR THE STRUCTURAL <br />DESIGN TO PERFORM STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM, <br />INCLUDING BUT NOT LIMITED TO THE ELEMENTS AND CONNECTIONS AT <br />SIGNIFICANT CONSTRUCTION STAGES AND THE COMPLETED STRUCTURE FOR <br />GENERAL COMPLIANCE TO THE APPROVED PLANS AND SPECIFICATIONS. <br />3. THE STRUCTURAL OBSERVER SHALL PROVIDE EVIDENCE OF EMPLOYMENT BY <br />THE OWNER. A LETTER FROM THE OWNER OR A COPY OF THE AGREEMENT FOR <br />SERVICES SHALL BE SENT TO THE BUILDING INSPECTOR BEFORE THE FIRST SITE <br />VISIT. THE STRUCTURAL OBSERVER SHALL ALSO INFORM THE OWNER OF THE <br />REQUIREMENTS FOR A PRE -CONSTRUCTION MEETING AND SHALL PRESIDE OVER <br />THIS MEETING. <br />4. A PRE -CONSTRUCTION MEETING INCLUDING THE ENGINEER FOR STRUCTURAL <br />OBSERVATION, THE CONTRACTOR, APPROPRIATE SUB CONTRACTORS, AND <br />SPECIAL INSPECTOR SHALL BE HELD TO REVIEW THE DETAILS OF THE <br />STRUCTURAL SYSTEM TO BE OBSERVED. <br />5. STRUCTURAL OBSERVATION NEITHER INCLUDES NOR WAIVES THE INSPECTIONS <br />BY THE BUILDING OFFICIAL OR SPECIAL INSPECTOR. THE ENGINEER SHALL <br />SUBMIT A STATEMENT IN WRITING TO THE BUILDING OFFICIAL THAT THE SITE <br />VISITS HAVE BEEN MADE AND WHETHER OR NOT ANY OBSERVED DEFICIENCIES <br />HAVE BEEN CORRECTED TO CONFORM TO THE APPROVED PLANS OR TO REVISED <br />DETAILS APPROVED BY THE BUILDING OFFICIAL. <br />6. THE STRUCTURAL OBSERVER SHALL PREPARE A REPORT FOR EACH SIGNIFICANT <br />STAGE OF CONSTRUCTION OBSERVED. THE ORIGINAL OF THE OBSERVATION <br />REPORT SHALL BE SENT TO BUILDING INSPECTOR'S OFFICE AND SHALL BE <br />SIGNED AND SEALED (WET STAMP) BY THE RESPONSIBLE STRUCTURAL <br />OBSERVER. ONE COPY OF THE OBSERVATION REPORT SHALL BE ATTACHED TO <br />THE APPROVED PLANS. THE COPY ATTACHED TO THE PLANS NEED NOT BE <br />SEALED BUT SHALL BE SIGNED BY THE RESPONSIBLE STRUCTURAL OBSERVER <br />OR THEIR DESIGNEE. COPIES OF THE REPORT SHALL ALSO BE GIVEN TO THE <br />OWNER, CONTRACTOR, AND DEPUTY INSPECTOR. <br />7. A FINAL OBSERVATION REPORT SHALL BE SUBMITTED WHICH SHOWS THAT ALL <br />OBSERVED DEFICIENCIES WERE RESOLVED AND THE STRUCTURAL SYSTEM <br />GENERALLY CONFORMS WITH THE APPROVED PLANS AND SPECIFICATIONS. THE <br />DEPARTMENT OF BUILDING AND SAFETY WILL NOT ACCEPT THE STRUCTURAL <br />WORK WITHOUT FINAL OBSERVATION REPORT AND THE CORRECTION OF <br />SPECIFIC DEFICIENCIES NOTED DURING NORMAL BUILDING AND DEPUTY <br />INSPECTION. <br />8. SHOULD THE OWNER ELECT TO CHANGE THE STRUCTURAL OBSERVER OF <br />RECORD, THE OWNER SHALL NOTIFY THE BUILDING INSPECTOR IN WRITING <br />BEFORE THE NEXT INSPECTION, CALL AN ADDITIONAL "PRE -CONSTRUCTION" <br />MEETING, AND FURNISH THE REPLACEMENT STRUCTURAL OBSERVER WITH A <br />COPY OF ALL PREVIOUS OBSERVATION REPORTS. THE REPLACEMENT <br />STRUCTURAL OBSERVER SHALL APPROVE THE CORRECTION OF THE ORIGINAL <br />OBSERVED DEFICIENCIES UNLESS OTHERWISE APPROVED BY PLAN CHECK <br />SUPERVISION. THE POLICY OF THE BUILDING DEPARTMENT SHALL BE TO <br />CORRECT ANY PROPERLY NOTED DEFICIENCY WITHOUT CONSIDERATION OF <br />THEIR SOURCE. <br />9. THE ENGINEER OF RECORD SHALL DEVELOP ALL CHANGES RELATING TO THE <br />STRUCTURAL SYSTEM. THE BUILDING DEPARTMENT SHALL REVIEW AND <br />APPROVE ALL CHANGES TO THE APPROVED PLANS AND SPECIFICATIONS. <br />10. THE STRUCTURAL OBSERVER SHALL PERFORM SITE VISITS AT THOSE STEPS IN <br />THE PROGRESS OF THE WORK THAT ALLOW FOR CORRECTION OF DEFICIENCIES <br />WITHOUT SUBSTANTIAL EFFORT OR UNCOVERING OF THE WORK INVOLVED. AT A <br />MINIMUM, SIGNIFICANT CONSTRUCTION STAGES REQUIRE A SITE VISIT AND AN <br />OBSERVATION REPORT FROM THE STRUCTURAL OBSERVER AS SHOWN ON THE <br />INSPECTION PROGRAM. <br />11. STAGES OF CONSTRUCTION REQUIRING OBSERVATION: <br />11.1. FOUNDATION: REBAR SIZE & PLACEMENT, SIZE OF FOUNDATION <br />11.2. SHEAR WALLS: CONNECTION HARDWARE & PLYWOOD NAILING. <br />11.3. ROUGH FRAMING: GENERAL CONFORMANCE TO DESIGN. <br />EPDXY ANCHORS AND DOWELS: (SIMPSON SET -XP EPDXY, ICC ESR -2508, LARRE25744, <br />LARRE25965) <br />1. BOLTS AND REINFORCEMENT EMBEDDED INTO CONCRETE OR MASONRY WITH <br />EPDXY SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND <br />APPROVED ICC REPORTS. <br />2. MINIMUM SUBSTRATE AND AMBIENT TEMPERATURE SHALL BE AS RECOMMENDED <br />BY MANUFACTURER PRIOR TO PLACING EPDXY. THE MINIMUM AGE OF <br />CONCRETE TO BE BONDED SHALL BE 21 DAYS, U.N.O. <br />3. THE HOLES SHALL BE DRILLED WITH AN ELECTRO-PNUMATIC ROTARY HAMMER <br />DRILL USING CARBIDE TIP BITS CONFORMING TO ANSI SPECIFICATION <br />B94-12-1977. THE HOLES SHALL BE CLEANED OF DUST AND DEBRIS WITH A <br />NYLON BRUSH AND A JET OF COMPRESSED AIR. HOLE DIAMETER AND DEPTH <br />SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS UNLESS NOTED <br />OTHERWISE. <br />4. CLEAN MACHINE BOLTS / REINFORCING BARS SHALL BE PLACED IN CLEAN <br />DRILLED HOLES THAT ARE PARTIALLY FILLED WITH EPDXY SO THAT SOME <br />EXCESS EPDXY COMES OUT OF THE HOLE. <br />5. ALL EPDXY ADHESIVE INSTALLATIONS SHALL HAVE CONTINUOUS SPECIAL <br />INSPECTION PER THE CURRENT CODE REQUIREMENTS. <br />SPECIAL INSPECTION <br />SPECIAL INSPECTION IN CONFORMANCE WITH CHAPTER 17 BY A DEPUTY REGISTERED <br />INSPECTOR APPROVED BY THE BUILDING DEPARTMENT SHALL BE PROVIDED FOR THE <br />FOLLOWING: (UNLESS NOTED OTHERWISE) <br />A. ALL CONCRETE WORK, INCLUDING REBAR PLACEMENT, EXCEPT <br />NON-STRUCTURAL SLABS ON GRADE AND FOUNDATION CONCRETE WHERE THE <br />STRUCTURAL DESIGN IS BASED ON f ❑ 2500 PSI. <br />B. ALL FIELD WELDING INCLUDING WELDING OF REBAR. <br />C. HIGH STRENGTH BOLTING. <br />D. SHOP WELDING IF NOT DONE BY AN APPROVED FABRICATOR. <br />E. ALL CONCRETE WORK FOR TILT -UP PANELS INCLUDING REBAR PLACEMENT, <br />AND CHORD BAR WELDING. QUALIFICATIONS OF SPECIAL INSPECTORS TO BE <br />USED SHALL <br />F. BE SUBMITTED TO ENGINEER OF RECORD PRIOR TO START OF CONSTRUCTION. <br />THE PERMIT APPLICANT SHALL RETAIN A RESPONSIBLE ENGINEER APPROVED BY THE <br />BUILDING OFFICIAL TO ENSURE THAT: <br />A. ALL ELEMENTS OF CONSTRUCTION WHICH REQUIRE SPECIAL INSPECTION ARE <br />INSPECTED BY QUALIFIED DEPUTY INSPECTORS APPROVED BY THE BUILDING <br />OFFICIALFAND <br />B. ALL CODE DEFICIENCIES DETECTED AND DEVIATIONS FROM THE APPROVED <br />PLANS ARE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR <br />CORRECTION, AND IF NOT CORRECTED, REVISED DESIGNS TO OVERCOME THE <br />DEFICIENCY SHALL BE PREPARED BY THE DESIGN ENGINEER OR ARCHITECT OF <br />RECORD FOR APPROVAL BY THE BUILDING OFFICIALFAND <br />C. ALL CORRECTIVE WORK REQUIRED IS COMPLETED IN ACCORDANCE WITH <br />APPROVED PLANS, SPECIFICATIONS, AND CITY ADOPTED CODES. <br />A FINAL INSPECTION REPORT, SIGNED BY THE DEPUTY INSPECTOR AND THE <br />RESPONSIBLE ENGINEER, IS SUBMITTED TO THE BUILDING OFFICIAL UPON THE <br />COMPLETION OF EACH ELEMENT REQUIRING SPECIAL INSPECTION. THE REPORT <br />MUST CERTIFY THAT THE WORK WAS IN COMPLIANCE WITH APPROVED PLANS, <br />SPECIFICATIONS AND APPLICABLE CITY CODES INCLUDING ANY AUTHORIZED <br />CHANGES TO THE PLANS. <br />DESIGN LOAD & CRITERIA: <br />1. SEISMIC DESIGN DATA <br />IMPORTANCE FACTOR, 1 ............................................1.0 <br />NAILING <br />(COMMON NAILS) <br />JOIST TO SILL OR GIRDER, TOENAIL <br />3-8d <br />SITECLASS................................................................. <br />2-8d <br />1"X6" SUB FLOOR OR LESS TO EACH JOIST, FACE NAIL <br />D <br />Ss..................................................................................0.882 <br />3-8d <br />2" SUB FLOOR TO JOIST OR GIRDER, BLIND AND FACE <br />NAILING <br />2-16d <br />S1..................................................................................0.331 <br />- o.c. <br />3-16d per 16" <br />TOP PLATE TO STUD, END NAIL <br />2-16d <br />SDs................................................................................0.675 <br />4-8d or 2-16d, end nail <br />DOUBLE STUDS, FACE NAIL <br />16d ❑ 24" o.c. <br />SD1................................................................................0.383 <br />16d ❑ 16" o.c. <br />8-16d <br />BLOCKING BETWEEN JOIST OR RAFTERS TO TOP <br />PLATE, TOENAIL <br />3-8d <br />SDC................................................................................D <br />8d ❑ 16" o.c. <br />TOP PLATES LAPS AND INTERSECTION, FACE NAIL <br />2-16d <br />BASIC SEISMIC FORCE -RESISTING SYSTEM ...........WOOD <br />SHEARWALL <br />BASE SHEAR - MAIN ......................................................0.844 <br />3-8d <br />CONTINUOUS HEADER TO STUD, TOENAIL <br />K <br />Cs...................................................................................0.104 <br />3-16d <br />CEILING JOIST TO PARALLEL RAFTERS, FACE NAIL <br />3-16d <br />R......................................................................................6.5 <br />3-8d <br />BUILT-UP CORNER STUDS <br />16d ❑ 24" o.c. <br />PROCEDURE USED......................................................EQUIVALENT <br />20d 32" o.c. <br />TYP <br />LATERAL FORCE <br />REDUNDANCY FACTOR...............................................1.3 <br />UNO <br />DWL <br />DOWEL <br />2. WIND DESIGN DATA <br />DWG <br />DRAWING <br />W/ <br />BASIC WIND SPEED ..................................................... <br />EXISTING <br />W/O <br />110 MPH <br />RISK CATEGORY......................................................... <br />WT <br />EF <br />II <br />WIND EXPOSURE........................................................ <br />EOS <br />EDGE OF SLAB <br />C <br />3. LOAD <br />ELEVATION <br />L0 <br />EN <br />ROOF (SHINGLE) <br />DL <br />10 PSF <br />EQUAL <br />L0 <br />LL <br />20 PSF <br />CEILING <br />DL <br />5 PSF <br />FL <br />FLOOR <br />LL <br />10 PSF <br />FOOT/FEET <br />EXT. WALL <br />DL <br />15 PSF <br />NAILING SCHEDULE: <br />NAILING <br />(COMMON NAILS) <br />JOIST TO SILL OR GIRDER, TOENAIL <br />3-8d <br />BRIDGING TO JOIST, TOENAIL EACH END <br />2-8d <br />1"X6" SUB FLOOR OR LESS TO EACH JOIST, FACE NAIL <br />2-8d <br />WIDER THAN 1"X6" SUB FLOOR TO EACH JOIST, FACE <br />NAIL <br />3-8d <br />2" SUB FLOOR TO JOIST OR GIRDER, BLIND AND FACE <br />NAILING <br />2-16d <br />SOLE PLATE TO JOIST OR BLOCKING, TYPICAL FACE <br />NAIL <br />SOLE PLATE TO JOIST OR BLOCKING, AT BRACED WALL <br />PANEL <br />- o.c. <br />3-16d per 16" <br />TOP PLATE TO STUD, END NAIL <br />2-16d <br />STUD TO SOLE PLATE <br />4-8d or 2-16d, end nail <br />DOUBLE STUDS, FACE NAIL <br />16d ❑ 24" o.c. <br />DOUBLE TOP PLATE, TYPICAL FACE NAIL <br />DOUBLE TOP PLATE, LAP SPLICE <br />16d ❑ 16" o.c. <br />8-16d <br />BLOCKING BETWEEN JOIST OR RAFTERS TO TOP <br />PLATE, TOENAIL <br />3-8d <br />RIM JOIST TO TOP PLATE, TOE NAIL <br />8d ❑ 16" o.c. <br />TOP PLATES LAPS AND INTERSECTION, FACE NAIL <br />2-16d <br />CONTINUOUS HEADER, TWO PIECES <br />❑ o.c. along each - <br />edge <br />CEILING JOIST TO PLATE, TOENAIL <br />3-8d <br />CONTINUOUS HEADER TO STUD, TOENAIL <br />4-8d <br />CEILING JOIST, LAPS OVER PARTITIONS, FACE NAIL <br />3-16d <br />CEILING JOIST TO PARALLEL RAFTERS, FACE NAIL <br />3-16d <br />RAFTER TO PLATE, TOENAIL <br />3-8d <br />BUILT-UP CORNER STUDS <br />16d ❑ 24" o.c. <br />BUILT-UP GIRDER OR BEAMS (AT TOP AND BOTTOM <br />AND STAGGERED 2-20D AT ENDS AND AT EACH SPLICE <br />20d 32" o.c. <br />NOTE: ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS <br />OR GALVANIZED BOX. <br />S TANDA RD ABBREVIA TIONS <br />AB <br />ANCHOR BOL T <br />OPP <br />APA <br />AMER/CAN PL YWOOD ASSOC/A TION <br />PL T <br />ARCH <br />ARCHITECTURAL/ARCHITECT <br />PLF <br />ALT <br />AL TERNA TE <br />PSF <br />BL KG <br />BL OCKING <br />PSI <br />BRG <br />BEARING <br />PSL <br />C <br />CHANNEL <br />PTDF <br />CBC <br />CALIFORNIA BUILDING CODE <br />REQ D <br />CL <br />CENTER LINE <br />SIM <br />CLR <br />CLEAR <br />SPEC <br />COL <br />COLUMN <br />STAGG <br />CONC <br />CONCRETE <br />STD <br />CONT <br />CONTINUOUS <br />TSB <br />DBL <br />DOUBLE <br />T&G <br />DIA <br />DIAMETER <br />TYP <br />DF <br />DOUGLAS FIR <br />UNO <br />DWL <br />DOWEL <br />VERT <br />DWG <br />DRAWING <br />W/ <br />EX OR (E) <br />EXISTING <br />W/O <br />EA <br />EACH <br />WT <br />EF <br />EACH FACE <br />EOS <br />EDGE OF SLAB <br />0 <br />ELEV <br />ELEVATION <br />L0 <br />EN <br />EDGENAILING <br />EQ <br />EQUAL <br />L0 <br />EW <br />EACH WAY <br />FF <br />FINISHED FL OOR <br />FL <br />FLOOR <br />FT <br />FOOT/FEET <br />FTG <br />FOO TING <br />GA <br />GAGE <br />A <br />GLB <br />GL UED-LA MINA TED BEAM <br />GSN <br />GENERAL STRUCTURAL NOTES <br />HGR <br />HANGER <br />HOR <br />HORIZONTAL <br />HSS <br />HOL L 0 W S TRUC TURA L STEEL <br />0 <br />INFO <br />INFORMA TION <br />JOIST <br />JS <br />K <br />KIP (1, 000 LBS) <br />KSI <br />KIPS PER SQUARE INCH <br />L <br />ANGLE <br />L SL <br />LAMINA TED STRAND L UMBER <br />L VL <br />LAMINATED VENEER LUMBER <br />MFR <br />MANUFACTURER <br />MAX <br />MAXIMUM <br />MECH <br />MECHANICAL <br />MIN <br />MINIMUM <br />M/SC <br />MISCELLANEOUS <br />NTS <br />NOT TO SCALE <br />OC <br />ON CENTER <br />OPPOSITE <br />PLA TE <br />POUND PER LINEAR FOOT <br />POUND PER SQUARE FOOT <br />POUND PER SQUARE INCH <br />PARALLEL STRAND L UMBER <br />PRESSURE TREA TED DOUGLAS FIR <br />REQUIRED <br />SIMILAR <br />SPECIFICA TION <br />STAGGERED <br />STANDARD <br />TOPAND BOTTOM <br />TONGUEAND GROOVE <br />TYPICAL <br />UNLESS NOTED OTHERWISE <br />VERTICAL <br />WITH <br />WITHOUT <br />WEIGHT <br />DMAC <br />)ESIGN ❑BUILD <br />5690 SCHAEFER AVENUE, SUITE A, CHINO, CA 91710 <br />t 909.927.8688 -f 909.927.8686 <br />info dmacse.com IFvww.dmacse.com <br />©2018 DMAC DESIGN + BUILD <br />This drawing and design is the property of DMAC Design+Build <br />It may not be used for any purpose other than by the owner. <br />DMAC Design + Build does not authorize the reproduction or <br />conveyance of any information contained herein without prior <br />written permission. <br />The Architect/Engineer assumes no responsibility or liability for <br />the use of these plans for any project other than specifically <br />authorized by them and signed and sealed for such specific <br />location in the State, Province or territory shown on the seal. <br />This building use is only applicable in areas meeting the stated <br />design criteria <br />DO NOT SCALE PLANS <br />Copying, Printing, Software and other processes required to <br />produce these prints can stretch or shrink the actual paper or <br />layout. Therefore, scaling of this drawing may be inaccurate. <br />Contact DMAC Design+Build with any need for additional <br />dimensions or clarifications. <br />Seal: <br />oQ�p F ESS/ON\ <br />E I - Cylr lF <br />No. 81058 z <br />CD m <br />U-1 m <br />EXP. 09/30/19 <br />it <br />CIV <br />9TFOF CA1\F��� <br />Pro ect Information: <br />W <br />Z <br />0 <br />�o <br />U <br />z <br />0 <br />J� <br />0< <br />w <br />=U <br />�^^ <br />VJ0 <br />Z <br />Z <br />Z <br />It- <br />0 <br />L.L <br />G <br />0 <br />W <br />W <br />Q <br />0 <br />0o <br />w <br />0 <br />L0 <br />W <br />�^ <br />W <br />00 <br />L0 <br />No. <br />Date <br />Revision <br />A <br />0 <br />0 <br />0 <br />Date <br />Issue <br />Proloct No.: 2018-099 <br />Scale: As Shown <br />Drawn / Check by: KK/DC <br />Date: 10/29/18 <br />Drawing Title: <br />STRUCTURAL <br />NOTES <br />Sheet: <br />SN1 <br />