<br />GENERAL NOTES
<br />HVAC GENERAL NOTES CON'T.
<br />LEGENDS, SYMBOLS AND ABBREVIATIONS
<br />LEGENDS, SYMBOLS AND ABBREVIATIONS CON'T
<br />1. CONTRACTOR SHALL VISIT JOB SITE, VERIFY FIELD CONDITIONS, REVIEW
<br />17. PROVIDE TO THE OWNER TWO SETS OF AS -BUILT DRAWINGS AND TWO
<br />PLAN AND SPECIFICATIONS AND SHALL INCLUDE IN HIS PRICE THE
<br />BOUND SETS OF ALL OPERATING MANUALS, DIAGRAMS SERVICE CONTRACTS,
<br />SYMBOL DESCRIPTION
<br />SYMBOL ABBREV. DESCRIPTION
<br />NECESSARY COST TO CONSTRUCT THIS PROJECT IN ACCORDANCE WITH THE
<br />GUARANTEES, ETC.
<br />TAGOT # -- DIGITAL PROGRAMMABLE THERMOSTAT
<br />MECHANICAL DRAWING AND SHALL MEET ALL APPLICABLE CODES.
<br />18. TEST AND BALANCE ALL EQUIPMENT AND DEVICES TO PERFORM AND
<br />UP EQUIPMENT TYPE
<br />CSD CEILING SUPPLY DIFFUSER W/ MANUAL
<br />®VOLUME
<br />LO EQUIPMENT NUMBER
<br />2. ALL MATERIAL AND EQUIPMENT FURNISHED AND INSTALLED SHALL BE NEW,
<br />DELIVER SPECIFIED QUANTITIES ON THE DRAWING. AIR BALANCING SHALL BE
<br />DAMPER
<br />FREE FROM DEFECTS AND SHALL BE GUARANTEED FOR A PERIOD OF ONE
<br />PERFORMED BY 3RD PARTY. SUBMIT 4 SET OF AIR BALANCE REPORT TO
<br />DETAIL DRAWING NUMBER
<br />❑HrP
<br />CRR CEILING RETURN REGISTER W MANUAL
<br />YEAR FROM DATE OF FINAL ACCEPTANCE BY THE OWNER. SHOULD ANY
<br />THE ENGINEER PRIOR FINAL.
<br />M-� DETAIL DRAWING PAGE
<br />",, rXfPP ■1-7
<br />JJ J'J`J�JJJ
<br />TROUBLE DEVELOP DURING THE PERIOD DUE TO FAULTY WORKMANSHIP OR
<br />VOLUME DAMPER
<br />aJJJ Dems
<br />MATERIAL, THE CONTRACTOR SHALL FURNISH ALL NECESSARY MATERIAL
<br />19. THE MATERIAL OF THE DUCTS SHALL BE AS FOLLOWING; a) EXPOSED
<br />UP DN
<br />CRR CEILING EXHAUST GRILLE W/ MANUAL
<br />SJe�r�V1C�e�Sj IrYL►C�.
<br />AND LABOR TO CORRECT THE TROUBLE WITHOUT COST TO THE OWNER.
<br />DUCTS GALVANIZED SHEET METAL WITH GAUGE PER LATEST SMACNA
<br />® SUPPLY1z
<br />VOLUME DAMPER
<br />JJJ.�J
<br />STANDARD. b DUCTS CONCEALED IN CEILING SPACE : GALVANIZED SHEET
<br />)
<br />RECTANGULAR DUCT SECTION/UP
<br />( OR PENETRATION THROUGH
<br />MVD/OBD MANUAL VOLUME / OPPOSED -BLADE
<br />ADR: 3119 Central Parkway,
<br />Dublin 4568
<br />3. CONTRACTOR IS TO REVIEW THE PLANS OF OTHER DISCIPLINES AND
<br />METAL WITH GAUGE PER LATEST SMACNA STANDARD OR
<br />® � EXHAUST
<br />8- 29
<br />TEL: 510-788-6029
<br />COORDINATE WITH THE WORK OF OTHER TRADES PRIOR TO INSTALLATION
<br />FACTORY -FABRICATED DUCT LISTED AND LABELED UMC 10-1 OR UL181
<br />FLOOR/ROOF).
<br />BALANCING DAMPER
<br />CEL: 510-468-0613
<br />FAX: 510-788-6039
<br />TO AVOID ANY CONFLICT BETWEEN DUCTS, CONDUITS, SPRINKLERS, PIPING,
<br />TESTED TO CAPABLE OF HANDLING 4" W.C. STATIC PRESSURE. C)
<br />® 0 RETURN
<br />UP DUCT UP WITH SMOOTH 900 ELBOW
<br />LIGHTING FIXTURES, ETC. NO EXTRAS WILL BE ALLOWED FOR CORRECTION
<br />BATHROOM & KITCHEN EXHAUST DUCTS AND DRYER VENTS : GALVANIZED
<br />DUCT DOWN WITH SMOOTH
<br />OF CONFLICTS DUE TO LACK OF COORDINATION.
<br />SHEET METAL INSTALL IN ACCORDANCE WITH METHODS AND STANDARDS OF
<br />DN
<br />QROFESS/p�
<br />o Nu i
<br />ASHRAE AND SMACNA FOR LOW PRESSURE CONSTRUCTION.
<br />20X00 B
<br />90G ELBOW
<br />���P
<br />9�
<br />4. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO
<br />(X� CEILING EXHAUST REGISTER
<br />AP ACCESS PANEL
<br />z
<br />W m
<br />DETERMINE EXACT LOCATION OF PIPING, DUCT WORK OR DIFFUSERS.
<br />20. FACTORY -FABRICATED DUCT SYSTEMS.
<br />J
<br />M353 4
<br />- 2 0 0
<br />B
<br />6/30/19
<br />A. ALL FACTORY -FABRICATED DUCT SYSTEMS SHALL COMPLY WITH UL 181
<br />20x10
<br />�A POC POINT OF CONNECTION
<br />s
<br />5. THE CONTRACTOR SHALL BRING TO THE ARCHITECT'S ATTENTION OF ANY
<br />FOR DUCTS AND CLOSURE SYSTEMS, INCLUDING COLLARS, CONNECTIONS
<br />o
<br />DISCREPANCY OR CONFLICTS IN THE PLANS OR THE SITE CONDITIONS. ALL
<br />AND SPLICES, AND BE LABELED AS COMPLYING WITH UL 181. UL 181
<br />(� CEILING RETURN REGISTER
<br />�� POD POINT OF DISCONNECT
<br />NECESSARY CHANGES MUST BE APPROVED IN WRITING BY THE ARCHITECT
<br />TESTING MAY BE PERFORMED BY UL LABORATORIES OR A LABORATORY
<br />CEILING SUPPLY TOP FIGURE INDICATES CFM.
<br />FSD FIRE AND SMOKE DAMPER COMBO
<br />BEFORE START OR WORK.
<br />APPROVED BY THE EXECUTIVE DIRECTOR.
<br />200 A BOTTOM FIGURES INDICATES
<br />�
<br />B. ALL PRESSURE -SENSITIVE TAPES, HEAT -ACTIVATED TAPES, AND MASTICS
<br />2 0x10x3 DIFFUSER WITH NECK SIZE DIRECTION AND
<br />FLEXIBLE DUCT
<br />DSD DSD DUCT -MOUNTED SMOKE DETECTOR
<br />Revisions
<br />Date
<br />6. CONTRACTOR TO SUBMIT CATALOG CUT SHEETS OF ALL THE MATERIAL
<br />USED IN THE MANUFACTURE OF RIGID FIBERGLASS DUCTS SHALL COMPLY
<br />(Xl NUMBER OF THROWS ON
<br />AND AIRFLOW
<br />AND EQUIPMENT TO BE USED AND WORKING SHOP DRAWINGS FOR
<br />WITH UL 181 AND UL 181 A.
<br />-200 SUPPLY DIFFUSER. DUCT SIZE
<br />B PATTERN
<br />PROGRESS REVIEW
<br />10-01-2018
<br />PERMIT SET
<br />10-29-2018
<br />APPROVAL BEFORE START OF WORK.
<br />C. ALL PRESSURE -SENSITIVE TAPES AND MASTICS USED WITH FLEXIBLE
<br />20x10 IS FULL SIZE OF DIFFUSER/
<br />LINE TYPE ABBREV. DESCRIPTION
<br />DUCTS SHALL COMPLY WITH UL 181 AND UL 181 B.
<br />SIDEWALL EXHAUST REGISTER CONNECTION. LETTER
<br />OR RETURN
<br />E 12x8 EXISTING DUCT TO REMAIN WITH EXISTING
<br />7. SUPPORTS FOR ALL PIPING AND DUCTWORK SHALL BE IN ACCORDANCE
<br />"GUIDELINES
<br />D. JOINTS AND SEAMS OF DUCT SYSTEMS AND THEIR COMPONENTS SHALL
<br />INSIDE CIRCLE INDICATES
<br />REGISTER
<br />(E) DIMENSIONS SHOWN
<br />WITH LATEST SMACNA FOR SEISMIC RESTRAINTS OR
<br />NOT BE SEALED WITH CLOTH -BACK RUBBER ADHESIVE DUCT TAPES
<br />DIFFUSER TYPE. SEE DIFFUSER
<br />E 12x8
<br />MECHANICAL SYSTEMS AND PLUMBING SYSTEMS".
<br />UNLESS SUCH TAPE IS USED IN COMBINATION WITH MASTIC AND
<br />SCHEDULE FOR DIFFUSER
<br />DRAWBANDS.
<br />21. DUCTWORK SHALL BE SUPPORTED PER SMACNA STANDARDS.
<br />TYPES.
<br />11 48 50Lx1 x2" B
<br />II LINEAR SLOT TOP FIGURE INDICATES CFM. BOTTOM
<br />FIGURE INDICATES LENGTH OF
<br />12x8 (N) EXISTING DUCT TO REMAIN WITH EXISTING
<br />DIMENSIONS SHOWN
<br />12x8
<br />HVAC GENERAL NOTES
<br />Preliminary set
<br />Design Review Set
<br />1. ALL WORK SHALL BE IN ACCORDANCE WITH ALL LOCAL, STATE AND
<br />I DIFFUSER SLOT/NUMBER OF SLOTS/SLOT WIDTH
<br />Plan Check Set
<br />x
<br />DRAWING INDEX
<br />FEDERAL CODES, LAWS AND REGULATIONS.11
<br />22. SEAL ALL TRANSVERSE JOINTS OF AIR DUCTS WITH DUCT SEALANT PER
<br />Plan Check Resubmit
<br />Construction Set
<br />2. ALL NEW DUCT SHALL BE SUPPORTED PER THE MINIMUM REQUIREMENT OF
<br />SMACNA STANDARD.
<br />12x8 RECTANGULAR DUCT WITH NET INSIDE DIMENSIONS
<br />LATEST SMACMA GUIDELINE, AND SHALL BE BRACED AND GUYED TO
<br />SHOWN IN INCHES.
<br />ME -0.1 MECHANICAL NOTES AND GENERAL INFORMATION
<br />PREVENT LATERAL OR HORIZONTAL SWING; THE USE OF SEISMIC RESTRAIN
<br />23. SUPPLY AND RETURN AIR DUCTS AND PLENUMS OF A HEATING OR COOLING
<br />------ DUCT WITH INTERNAL ACOUSTICAL INSULATION.
<br />12x8--
<br />ME -0.2 MECHANICAL SCHEDULES
<br />ME -0.3 MECHANICAL DETAILS
<br />GUIDELINES PER SMACNA IS ALSO APPLICABLE 604.2 and 604.5. FASTEN
<br />( )
<br />SYSTEM SHALL BE INSULATED TO ACHIEVE THE MINIMUM THERMAL (R)
<br />-- DIMENSIONS SHOWN ARE NET INSIDE IN INCHES.
<br />ME -0.4 MECHANICAL PRESCRIPTIVE TITLE 24 COMPLIANCE
<br />ALL DUCT WORK JOINTS AND SEAMS WITH SHEET METAL SCREW AND
<br />VALUE AS SET FORTH IN 2016 CMC TABLE E 503.7.2(2) AND 503.7.3(1).
<br />ME -0.5 MECHANICAL PRESCRIPTIVE TITLE 24 COMPLIANCE
<br />CAULK AIR TIGHT TO AVOID AIR STREAK.
<br />APPROVED MATERIALS SHALL BE INSTALLED ON DUCTS AND PLENUMS FOR
<br />12"0 ROUND DUCT WITH NET INSIDE DIMENSION
<br />ME -0.6 MECHANICAL PRESCRIPTIVE TITLE 24 COMPLIANCE
<br />INSULATING, SOUND DEADENING, OR OTHER PURPOSES. MATERIALS SHALL
<br />SHOWN
<br />ME -0.7 MECHANICAL PRESCRIPTIVE TITLE 24 COMPLIANCE
<br />3. CONTRACTOR IS DIRECTED TO VISIT SITE AND BE FULLY COGNIZANT OF
<br />HAVE A MOLD, HUMIDITY, AND EROSION -RESISTANT SURFACE THAT MEETS
<br />12"0 SS 316L WELDED STAINLESS STEEL DUCT
<br />ALL CONDITIONS PRIOR TO PROPOSAL. VERIFY EXACT LOCATION,
<br />THE REQUIREMENTS OF THE REFERENCED STANDARD FOR AIR DUCTS IN
<br />ME -1.0 GROUND FLOOR REFLECT CEILING PLAN
<br />ELEVATIONS, SIZES AND CONDITIONS OF EXISTING UTILITIES, DUCTS AND
<br />CHAPTER 17. INSULATION APPLIED TO THE SURFACE OF DUCTS, INCLUDING
<br />SQUARE ELBOW W/ TURNING VANES IN SUPPLY DUCT
<br />ME -2.0 ROOF MECHANICAL PLAN
<br />PIPING ASSOCIATED WITH THE PROJECT ANY EXTRA EXPENSE DUE TO
<br />DUCT COVERINGS, LININGS, TAPES, AND ADHESIVES, LOCATED IN BUILDINGS
<br />ONLY
<br />FAILURE TO MAKE SUCH EXAMINATION. SHALL NOT BE MADE. WHERE
<br />SHALL HAVE A FLAME -SPREAD INDEX NOT GREATER THAN TWENTY-FIVE
<br />ME -3.0 KITCHEN HOOD DETAILS
<br />CHANGES IN THE EXISTING WORK ARE NECESSARY TO PERMIT THE
<br />INSTALLATION OF NEW WORK, THEY SHALL BE MADE AT NO ADDITIONAL
<br />(25) AND A SMOKE DEVELOPED INDEX NOT GREATER THAN FIFTY (50),
<br />%
<br />ME -3.1 KITCHEN HOOD EXHAUST FAN DETAIL AND WIRING DIAGRAM
<br />Z
<br />WHEN TESTED AS A COMPOSITE INSTALLATION.
<br />/ R/D =1.5, 90° / 45° RADIUS
<br />COST TO THE OWNER.
<br />ELBOW
<br />SCOPE OF WORK
<br />O
<br />4. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED UTILITY
<br />24. RECTANGULAR DUCT AND PLENUMS SHALL BE FABRICATED OF GALVANIZED
<br />STEEL. INSULATE PLENUMS AND RECTANGULAR DUCTING AS INDICATED.
<br />ROUND DUCT TAP ON RECTANGULAR DUCT
<br />FURNISH AND INSTALL HVAC SYSTEM FOR TENANT SPACE WITH ALL
<br />SERVICES, INSPECTIONS AND PERMITS.
<br />12x8
<br />0
<br />DUCT SHALL HAVE THE MINIMUM GAUGE PER SMACNA. FOR PRODUCT
<br />TAP ENTRY AREA EQUALS 150% OF BRANCH AREA
<br />OTHER REQUIRED COMPONENTS FOR PROPER SYSTEM FUNCTIONALITY.
<br />5. ALL MECHANICAL WORK SHALL BE CONCEALED, UNLESS OTHERWISE NOTED.
<br />CONVEY DUCT, MINIMUM GAUGE OF SHEET METAL SHALL MEET
<br />�e
<br />REQUIREMENTS LISTED ON 2016 CMC TABLE 506.2(1) AND TABLE 506.2(2).12x8
<br />RECT. DUCT TAP ON RECTANGULAR DUCT
<br />FURNISH AND INSTALL KITCHEN HOOD MAKE-UP AIR AND EXHAUST
<br />TAP ENTRY AREA EQUALS 150% OF BRANCH AREA
<br />SYSTEM WITH ALL OTHER REQUIRED COMPONENTS FOR PROPER SYSTEM
<br />6. CLEAN THE PREMISES ON A DAILY BASIS TO LEAVE WORK AREA IN AN
<br />FUNCTIONALITY.
<br />UNCLUTTERED CONDITION.
<br />25. CONTRACTOR SHALL COORDINATE WITH ARCHITECT BEFORE PURCHASING
<br />O
<br />DIFFUSERS AND REGISTERS FOR APPROPRIATE SIZE, TYPE, FINISH, AND
<br />ROUND DUCT WITH 45°
<br />0 PROVIDE MATERIAL AND LABOR FOR HAVC SYSTEM BALANCING, TESTING,
<br />7. INSTALL THE ENTIRE MECHANICAL SYSTEM TO ELIMINATE ANY
<br />INSTALLATION LOCATION.
<br />TAKE -OFF
<br />AND SCHEDULING.
<br />OBJECTIONABLE VIBRATION AND NOISE.
<br />26. VERIFY THERMOSTAT/SWITCH LOCATIONS W/ARCHITECT PRIOR TO
<br />CONCENTRIC / ECCENTRIC DUCT REDUCER
<br />0 FURNISH AND INSTALL RESTROOM VENTILATION SYSTEM WITH ALL OTHER
<br />8. NOTIFY OWNER'S REPRESENTATIVE IMMEDIATELY IF A DISCREPANCY
<br />INSTALLATION.
<br />RECTANGULAR TO RECTANGULAR, ROUND TO ROUND
<br />REQUIRED COMPONENTS FOR PROPER SYSTEM FUNCTIONALITY.
<br />BETWEEN THE DRAWING AND THE ACTUAL SITE CONDITION OCCURS. STOP
<br />OR DUCT TO FILTER HOUSING TRANSFORMATION.
<br />THE WORK THAT IS AFFECTED AND OBTAIN INSTRUCTION FROM THE
<br />MAX. 150 INCLUDED ANGLE EXCEPT WHERE SHOWN
<br />f
<br />,
<br />OWNER'S REPRESENTATIVE BEFORE THE WORK CAN BE RESTARTED.
<br />27. MECHANICAL CONTRACTOR SHALL PROVIDE ALL APPURTENANCES WHICH
<br />OTHERWISE.
<br />SHALL INCLUDE BUT NOT LIMITED TO WIRING IN CONDUIT AS REQUIRED BY
<br />CALIFORNIA GREEN BUILDING CODE NOTES
<br />9. THE DRAWING INDICATES THE GENERAL ARRANGEMENT AND LOCATION OF
<br />CODE, CONTROL DEVICES, DAMPER, ACTUATORS, MOTORS, LINKAGES,
<br />RECTANGULAR TO ROUND DUCT TRANSFORMATION
<br />>=
<br />1. THE PERMANENT HVAC SYSTEM SHALL ONLY BE USED DURING
<br />PIPING, DUCTWORK, AND EQUIPMENT. MAKE DEVIATIONS SUCH AS OFFSETS
<br />CONTROLLERS, RELAYS, CONTRACTORS, REDUCED VOLTAGE TRANSFORMERS,
<br />CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR AREAS
<br />U)IN
<br />DUCTS AND PIPES THAT ARE NECESSARY TO MEET SITE CONDITIONS
<br />PNEUMATIC TUBES, PNEUMATIC CONTROL VALVES, ETC. AS REQUIRED TO
<br />MANUAL SINGLE BLADE OR MULTIPLE BLADE
<br />OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE
<br />F ---AND
<br />TO COORDINATE WORK WITH OTHER TRADES. ALL DEVIATIONS TO THE
<br />AUTOMATICALLY PERFORMED ALL FUNCTIONS.
<br />VOLUME DAMPER
<br />RANGE FOR MATERIAL AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM
<br />Wz p
<br />CONTRACT DOCUMENT, WHETHER SHOWN OR NOT, SHALL BE THE
<br />FSD
<br />IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A
<br />O~
<br />CV
<br />RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE MADE AT NO EXTRA
<br />28. DUCT TESTING AND SEALING SHALL BE PERFORMED BY HERS RATER AND
<br />FIRE/SMOKE DAMPER W/ DUCT ACCESS
<br />MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8. REPLACE ALL
<br />W J LO
<br />EXPENSE TO THE OWNER.
<br />THE CERTIFICATE & FORMS SHALL BE SUBMITTED TO THE CITY.
<br />PANEL
<br />FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS
<br />OCCUPIED DURING ALTERATION, AT THE CONCLUSION OF CONSTRUCTION.
<br />2 Q
<br />0
<br />10. OBTAIN AND FOLLOW MANUFACTURER'S DIRECTIONS WHEN INSTALLING NEW
<br />29. PROVIDE ACCESS PANELS FOR ALL FIRE DAMPERS, FIRE/SMOKE DAMPERS
<br />FLEXIBLE CONNECTION IN
<br />Z U
<br />EQUIPMENT. SUBMIT OPERATING AND MAINTENANCE MANUALS.
<br />AND ACCESS FOR SHUT-OFF AND CONTROL VALVES. COORDINATE ALL
<br />DUCT
<br />2. AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE
<br />an 0
<br />CEILING AND WALL ACCESS WITH GENERAL CONTRACTOR.
<br />CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND
<br />Q z
<br />11. COORDINATE ALL CUTTING AND PATCHING WITH GENERAL CONTRACTOR,
<br />VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION
<br />O
<br />INDIVIDUAL SUB -CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING
<br />ABBR. DESCRIPTION ABBR. DESCRIPTION
<br />COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET
<br />V z
<br />AND PATCHING TO THEIR WORK.
<br />30. FIRE DAMPER AND FIRE/SMOKE COMBINATION DAMPERS SHALL BE LABELED
<br />METAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO
<br />O z W
<br />BY AN APPROVED TESTING AND LISTING AGENCY.
<br />AFF ABOVE FINISHED FLOOR FR FROM
<br />REDUCE THE AMOUNT OF DUST, WATER AND DEBRIS WHICH MAY ENTER
<br />Q m U
<br />12. COORDINATE ALL WORK WITH ARCHITECTURAL, ELECTRICAL AND
<br />THE SYSTEM.
<br />LzLJ r
<br />STRUCTURAL, AND PLUMBING DRAWINGS, INSTALL ALL WORK TO CLEAR
<br />APPLICABLE CODE
<br />BLDG BUILDING GE GREASE EXHAUST
<br />F___00
<br />U)NEW
<br />AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS.
<br />BSMT BASEMENT
<br />3. IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED
<br />ICS IN CEILING SPACE
<br />AREAS OF THE BUILDING WITH AIR FILTRATION MEDIA FOR OUTSIDE AND
<br />13. FURNISH AND INSTALL COMPLETE ALL MATERIALS, EQUIPMENT AND LABOR
<br />2016 CALIFORNIA BUILDING CODE
<br />2016 CALIFORNIA MECHANICAL CODE
<br />CFF CAP FOR FUTURE INS INSULATION (THERMAL)
<br />RETURN AIR THAT PROVIDES AT LEAST A MINIMUM EFFICIENCY REPORTING
<br />AS SHOWN AND AS NECESSARY FOR COMPLETE WORKABLE SYSTEM.
<br />2016 CALIFORNIA PLUMBING CODE
<br />CLG CEILING
<br />VALUE (MERV) OF 8. MERV8 FILTER SHALL BE INSTALLED PRIOR TO
<br />Scale: AS NOTED
<br />201 6 CALIFORNIA ENERGY CODE
<br />CSD CEILING SUPPLY DIFFUSER NIC NOT IN CONTRACT
<br />OCCUPANCY, AND RECOMMENDATION FOR MAINTENANCE WITH FILTERS OF
<br />14. CONTRACTOR SHALL GUARANTEE THAT THE WORK DONE UNDER THIS
<br />2016 CALIFORNIA FIRE CODE
<br />THE SAME SHALL BE INCLUDED IN THE OPERATION AND MAINTENANCE
<br />Drawn By: AL
<br />SPECIFICATION WILL BE FREE FROM FAULTY MATERIALS OR WORKMANSHIP
<br />2016 CALIFORNIA GREEN BUILDING CODE
<br />EA EXHAUST AIR OSA OUTSIDE AIR (FRESH AIR)
<br />MANUAL.
<br />AND HEREBY AGREES, UPON RECEIVING NOTIFICATION FROM THE OWNER,
<br />2016 NEPA 13
<br />AND TO ITS ENTIRE SATISFACTION, ALL DEFECTS, DAMAGES OR
<br />ALL AMENDMENTS AND SUPPLEMENTS TO ABOVE CODES
<br />DN DOWN SA SUPPLY AIR
<br />4. PROGRAM HEATING AND COOLING SET -POINTS OF AC UNITS THAT ARE
<br />Approved By: JP
<br />IMPERFECTIONS APPEARING IN SAID WORK WITHIN A PERIOD OF ONE(1)ALL
<br />CITY OF STOCKTON ORDINANCES AND AMENDMENTS TO ABOVE CODES
<br />SAD SEE ARCHITECTURAL DRAWINGSERVING
<br />A COMMON AREA IDENTICALLY TO PREVENT AC SYSTEM FROM
<br />FA FRESH AIR SOV SHUT-OFF VALVE
<br />SIMULTANEOUSLY HEAT AND COOL OPERATION.
<br />Job: 18033
<br />YEAR FROM DATE OF FILING NOTICE OF COMPLETIONS.
<br />Sheet:
<br />SRR SIDEWALL RETURN REGISTER
<br />FL FLOOR
<br />15. ALL SUPPLY AIR DUCTWORK WITHIN UN -CONDITIONAL SPACE SHALL BE
<br />FR FROM
<br />MECHANICAL NOTES
<br />EXTERNALLY OR INTERNALLY INSULATED WITH MINIMUM R-8 INSULATION.
<br />UTR UP THROUGH ROOF
<br />AND GENERAL
<br />16. RESTORE ALL DAMAGE AND LEAVE PREMISES IN CLEAN CONDITION WHEN
<br />VTF VENT THROUGH ROOF
<br />INFORMATION
<br />FINISHED WITH WORK.
<br />of: ME=Oml
<br />
|