Laserfiche WebLink
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL H'E'ALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sagov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility <br />Food Mart Gasoline <br /># <br />Facility <br />2185 E. Fremont, Stockton <br />I C2 <br />Inspection <br />Sep 23, 2013 <br />Name; <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />Address: <br />File Review <br />Date: <br />Facility Jo inder Lal <br />g <br />103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />Title: owner <br />106 CCR 2632(b) Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />Phone: <br />Contact: <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />109 CCR 2638 (e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 HSC 25291(f) Annual line leak detector test not performed (M1) <br />111 HSC 25284.2 Annual spill containment testing not performed <br />112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br />Inspection X Routine X Monitoring System Certification I Installation _ Complaint - ID#: <br />❑ Other: <br />Type: <br />117 CCR 2661 Permit to repair UST system not obtained <br />118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) Permit to temporarily close UST system not obtained <br />(Authority HSC 25289) <br />K. Sidhu <br />201 <br />Consentfor. Xlnspection XSampling XPhotos <br />CCR 2712(b) <br />Granted by:Rajvinder <br />Title: <br />Monitoring VdROOt TLS -350R <br />Panel: eeef- <br />Piping <br />System: <br />-1 Pressurized XSuction _ Gravity <br />Overfill <br />Prevention: <br />F-1MechanicalXAudible/visual <br />UST <br />4 <br />5 <br />6 <br />- ----- <br />-------------- <br />-------------- <br />-------------- <br />-------- --- <br />---- <br />---Product --- <br />--87-octane -- <br />--87-octane -- <br />-----DSL <br />---------- <br />Designated <br />operator: AffOrdatest <br />ICC Exp. <br />Date: <br />Violations: Detection <br />F1M1-Release M2 -Release Prevention - M3 - Both <br />On Site Service FelixRamirez5273934 ICC Exp. <br />12/6/2014 Manufacturer'srVR 634976 6/25/14; VMI 11/10/13 <br />Technician: <br />#2516 <br />VIOLATIONS <br /># <br />C1 <br />I C2 <br />M <br />I Code Section <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation, M = Minor violation <br />File Review <br />101 HSC 25284 No permit to operate <br />102 HSC 25404.5 Annual operating fees not paid <br />103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 CCR 2632(b) Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 CCR 2637 Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (fl test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />109 CCR 2638 (e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 HSC 25291(f) Annual line leak detector test not performed (M1) <br />111 HSC 25284.2 Annual spill containment testing not performed <br />112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br />114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br />115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />ermit conditions <br />116 HSC 25292.5 Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 CCR 2661 Permit to repair UST system not obtained <br />118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) Permit to temporarily close UST system not obtained <br />120 HSC 25298(c) Permit to close UST system not obtained <br />On Site Records <br />201 <br />CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/2 years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 <br />CCR 2712(i) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 <br />CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Inspector: Received By: Title: <br />Jeffrey Wong (209) 468-0335 /� ��"< < C, , y' <br />EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />