My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2185
>
2300 - Underground Storage Tank Program
>
PR0231118
>
COMPLIANCE INFO 2009 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2023 2:30:31 PM
Creation date
10/21/2019 2:23:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2018
RECORD_ID
PR0231118
PE
2371
FACILITY_ID
FA0003284
FACILITY_NAME
FOOD MART GASOLINE*
STREET_NUMBER
2185
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14113045
CURRENT_STATUS
01
SITE_LOCATION
2185 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 1111111111 <br />Appendix VI <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at httpJ/www.waterboards.ca.gov.) O C T 2,4' ?0V <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California EALI$�1 <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code �LI1To/f�1 TALHTALHE <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. <br />General Information <br />Facility <br />N. FOOD & GAS VALERO <br />Site <br />Arldracs. 2185 E FREMONT ST <br />Facility Contact <br />Pr?rsnn YUGIRDER <br />Make/Model of Monitoring System: VEEDER ROOT TLS -350 <br />Bldg. No.: <br />City: STOCKTON CA <br />Zip: <br />Contact Phone No.: (-209) 547-1700 <br />B. Inventory of Equipment Tested/Certified <br />Check the aoorooriate boxes to indicate specific eauipment inspected/serviced: <br />Date of Testing/Servicing: 9-24-121 <br />Tank ID: 870CT <br />Signature: T <br />Certification No.: 34975 <br />Tank ID: DSL <br />Testing Company Name: AFFORDA-TEST <br />21 In -Tank Gauging Probe. <br />Model: <br />MAG 1 <br />In -Tank Gauging Probe. <br />Model: MAG 1 <br />® Annular Space or Vault Sensor. <br />Model: <br />420 <br />❑ Annular Space or Vault Sensor. <br />Model: SPLIT <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />® Piping Sump /Trench Sensor(s). <br />Model: 208 <br />® Fill Sump Sensor(s). <br />Model: <br />208 <br />® Fill Sump Sensor(s). <br />Model: 208 <br />® Mechanical Line Leak Detector. <br />Model: <br />LD -2000 <br />® Mechanical Line Leak Detector, <br />Model: STP -MLD -D <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: 91 OCT <br />Tank ID: <br />❑ In -Tank Gauging Probe. <br />Model: <br />® In -Tank Gauging Probe. Model: MAG 1 <br />❑ Annular Space or Vault Sensor. <br />i <br />Model: <br />SPLIT <br />❑ Annular Space or Vault Sensor <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />® Fill Sump Sensor(s). <br />Model: <br />208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: <br />STP -MLD <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 5-6 <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 3-4 <br />Dispenser ID: 7-8 <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />IRI ni�pa c=r cQ_t_;n. ncnt Ecncc. -, <br />ModcL 202 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />"If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check al/ that apply): ® System set-up ® Alarm history report <br />Technician Name (print): David A. Winkler <br />Signature: T <br />Certification No.: 34975 <br />License No: OTT 08--11739 <br />Testing Company Name: AFFORDA-TEST <br />Phone No. (209) 744-0113 <br />Testing Company Address: 416 2" STREET GALT, CA 95632 <br />Date of Testing/Servicing: 9-24-12 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.