My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2185
>
2300 - Underground Storage Tank Program
>
PR0231118
>
COMPLIANCE INFO 2009 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2023 2:30:31 PM
Creation date
10/21/2019 2:23:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2018
RECORD_ID
PR0231118
PE
2371
FACILITY_ID
FA0003284
FACILITY_NAME
FOOD MART GASOLINE*
STREET_NUMBER
2185
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14113045
CURRENT_STATUS
01
SITE_LOCATION
2185 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s4gov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Food Mart Gasoline Facility 2185 E. Fremont, Stockton Inspection Se 24, 2012 <br />Name: Address: Date: p <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safe Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMY OF VIOL TIONS <br />CLASS I, =ASS o OR -Notice to Comply) <br />This is a Routine and Monitoring System Certification inspection. The following violation #105 is a <br />Minor -Notice to comply, and the #311 is a Class II Repeat violation. <br />105. UST tank forms on file with the EHD are not current: All three tank forms listed the riser, as well as <br />vent and vapor -return piping to be double -walled steel construction, which EHD inspector was unable to <br />verify for the riser during this inspection. Any change of information on these forms must be submitted <br />to the EHD within 30 days of the changes. Immediately complete and submit a copy of the facility and <br />tank forms to the EHD by 10/24/2012. Complete a separate tank form for each tank. <br />311. (Repeat) The 87 -octane VMI line leak detector failed to detect a leak when tested, even after the <br />service technician adjusted the leak detector and retested it. All line leak detectors shall be capable of <br />detecting a 3 -gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, and certified <br />contractor repair or replace the failed leak detector (LG 113-x listed, if applicable) and obtain a permit <br />within one business day from the EHD. If the failed leak detector can't be replaced immediately, there is <br />a possibility that the 87 -octane UST system may be red tagged to prevent fuel inputs. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EH ' URRENT HOURLY RATE. <br />
The URL can be used to link to this page
Your browser does not support the video tag.