My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2185
>
2300 - Underground Storage Tank Program
>
PR0231118
>
COMPLIANCE INFO 2009 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2023 2:30:31 PM
Creation date
10/21/2019 2:23:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2018
RECORD_ID
PR0231118
PE
2371
FACILITY_ID
FA0003284
FACILITY_NAME
FOOD MART GASOLINE*
STREET_NUMBER
2185
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14113045
CURRENT_STATUS
01
SITE_LOCATION
2185 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.html <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Food Mart Gasoline Facilely 2185 E. Fremont, Stockton Inspection <br />Name: Sep 19, 2011 <br />Address. Date: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 CCR 2643(e) Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (Mt) <br />703 CCR 2643(d) Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />This is an annual monitoring certification and routine inspection. The following violations were observed: <br />311. The diesel line leak detector failed to detect a leak when tested. All line leak detectors shall be <br />capable of detecting a 3 -gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, <br />and certified contractor repair or replace the failed leak detector (LG 113-x listed, if applicable) and <br />obtain a permit within one business day from the EHD. If the failed leak detector can't be replaced <br />immediately, there is a possibility that the UST system may be red tagged to prevent fuel inputs. <br />313. The 87 -octane spill container failed when tested. All spill containers shall have a minimum capacity <br />of five gallons and be capable of containing a spill or overfill until it is detected or cleaned up. <br />Immediately contact a properly licensed, trained, and certified contractor to repair or replace the spill <br />container under permit and inspection of the EHD. <br />314. The external audible and visual (enunciator and light) alarm used as the overfill prevention system <br />is not currently functional on the diesel, 87 and 91 -octane UST. Immediately discontinue deposition of <br />petroleum into these tanks until the component is repaired or replaced by a properly licensed, trained, <br />and certified contractor under permit and inspection of the EHD. If the failed component can't be <br />replaced immediately, there is a possibility that the UST system may be red tagged to prevent fuel <br />inputs. The inventory during this inspection is 3,569 gallons for the 87 -octane tank, 2,144 gallons for the <br />91 -octane tank, and 2,454 gallons for the diesel tank. <br />NOTES <br />Complete and submit a copy of the Return to Compliance Certification form (provided with the report) <br />with a statement of how each violation was corrected, including supporting documentation, by October <br />20, 2011. <br />Sugt Singh (a friend working at the cashier for Ranjit while he was out to lunch) signed and received the <br />report. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />T IS FACILITY IS SUB T TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />
The URL can be used to link to this page
Your browser does not support the video tag.