SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.html <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Food Mart Gasoline Facilely 2185 E. Fremont, Stockton Inspection <br />Name: Sep 19, 2011 <br />Address. Date: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 CCR 2643(e) Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (Mt) <br />703 CCR 2643(d) Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />This is an annual monitoring certification and routine inspection. The following violations were observed: <br />311. The diesel line leak detector failed to detect a leak when tested. All line leak detectors shall be <br />capable of detecting a 3 -gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, <br />and certified contractor repair or replace the failed leak detector (LG 113-x listed, if applicable) and <br />obtain a permit within one business day from the EHD. If the failed leak detector can't be replaced <br />immediately, there is a possibility that the UST system may be red tagged to prevent fuel inputs. <br />313. The 87 -octane spill container failed when tested. All spill containers shall have a minimum capacity <br />of five gallons and be capable of containing a spill or overfill until it is detected or cleaned up. <br />Immediately contact a properly licensed, trained, and certified contractor to repair or replace the spill <br />container under permit and inspection of the EHD. <br />314. The external audible and visual (enunciator and light) alarm used as the overfill prevention system <br />is not currently functional on the diesel, 87 and 91 -octane UST. Immediately discontinue deposition of <br />petroleum into these tanks until the component is repaired or replaced by a properly licensed, trained, <br />and certified contractor under permit and inspection of the EHD. If the failed component can't be <br />replaced immediately, there is a possibility that the UST system may be red tagged to prevent fuel <br />inputs. The inventory during this inspection is 3,569 gallons for the 87 -octane tank, 2,144 gallons for the <br />91 -octane tank, and 2,454 gallons for the diesel tank. <br />NOTES <br />Complete and submit a copy of the Return to Compliance Certification form (provided with the report) <br />with a statement of how each violation was corrected, including supporting documentation, by October <br />20, 2011. <br />Sugt Singh (a friend working at the cashier for Ranjit while he was out to lunch) signed and received the <br />report. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />T IS FACILITY IS SUB T TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />