Laserfiche WebLink
San Joaquin County <br />oP°"'" .� Environmental Health Department DIRECTOR <br />�•' —�� •� Donna Heran. RENS <br />600 East Main Street <br />Stockton, California 95202-3029 PROGRAM COORDINATORS Robert McClellon, REHS <br />-� Jeff Carruesco, REHS, RDI <br />cd ..-.. �i�P Website: www.sjgov.org/ehd Kasey Foley, REHS <br />6 F o R Linda Turkatte, REHS <br />Phone: (209) 468-3420 <br />September 26, 2011 Fax: (209) 464-0138 <br />Carrie Miller <br />Elite IV Contractors, Inc. <br />2535 Wigwam Dr. <br />Stockton, CA 95205 <br />Re: Valero Food Mart Gasoline SR0063540 <br />2185 E. Fremont <br />Stockton, CA 95202 <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of <br />the application for a permit to replace the diesel line leak detector, repair the spill bucket 87 - <br />octane fill sump, and replace the audible/visual alarm unit for overfill prevention on the <br />underground storage tank (UST) system at the above noted address. The permit has been <br />approved with the following conditions: <br />Contact the local fire department and the San Joaquin Valley Air Pollution Control <br />District for any applicable permits and requirements. <br />2. Any changes in information and scope of work must be submitted to EHD for approval <br />prior to commencing work. All new addenda supersede the previous ones. <br />3. Contact Jeff Wong at (209) 468-0335 to arrange the following inspection appointments <br />(a 48-hour notice is required for inspection appointments). Please be aware that <br />inspections for emergency work must be scheduled within five days of permit approval. <br />a. Leak detector test: Leak detector must be tested to confirm that the device can <br />detect a leak of 3 gallons per hour at 10 psi. <br />b. Overfill prevention verification: Verify that external audio and visual alarm activates <br />when tank is 90% full. <br />c. Spill bucket test: Verify minimum 5 -gallon capacity and pass a one hour hydrostatic <br />test (or equivalent). Proper drainage must also be verified. <br />Please be aware that the facility cannot operate the UST system tank prior to the <br />EHD inspection and approval. <br />4. Qualified service technicians must possess or work under the direct and personal <br />supervision of an individual physically present at the work site who possesses all of the <br />following: <br />a. One of several permissible valid, current contractor's licenses issued by the <br />Contractors State License Board (may be issued to the installation company), or a <br />Tank Tester's license issued to the individual by the State Water Board, and <br />b. A valid, current California UST Service Technician certificate issued by the <br />International Code Council (ICC), and <br />r f �t CCTY <br />