My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2185
>
2300 - Underground Storage Tank Program
>
PR0231118
>
COMPLIANCE INFO 2009 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2023 2:30:31 PM
Creation date
10/21/2019 2:23:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2018
RECORD_ID
PR0231118
PE
2371
FACILITY_ID
FA0003284
FACILITY_NAME
FOOD MART GASOLINE*
STREET_NUMBER
2185
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14113045
CURRENT_STATUS
01
SITE_LOCATION
2185 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENI <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />UNDERGROUND STORAGE TANK UST PROGRAM INSPECTION REPORT <br />Facility name:II n / <br />C�� `vY�-Q. <br />Facility address: <br />�I S f I <br />Facility Pontact: � ^ itlPhone: <br />i— <br />ng system: <br />Mo itoring Panel- Xessurized <br />V TLS S 50 ❑ Suction ❑ Gravity <br />Designated Operator: Inspection <br />I�'�'� �ir,�a�l k -S �t <br />UST # <br />'Product � (" <br />Overfill prevention: <br />❑ Mechanical dible/visual <br />Inspection type: <br />Routine onitoring Certification ❑ Installation ❑ Other: <br />Violations: <br />❑ M1-RDetect M2-RPrev ❑ M-3 Both <br /># <br />Code Section <br />VIOLATION(S) HSC=California Health & Safety Code; CCR=California Code of Regulations V R <br />V=Violation; RV=Re eat Violation V <br />1 <br />HSC 25284 <br />Permit tooperate <br />2 <br />3 <br />CCR 2637 <br />CCR 2711 b & c <br />Seconda containment test performed <br />Current Unified Program Consolidated Forms on file with EHD(Facility <br />and tank form <br />4 <br />HSC 25292.2 <br />Certification of financial responsibility and CFO letter <br />5 <br />CCR 2632 b <br />Monitoring Program(Monitoring & Response Plan is current and approved by the local agency. <br />6 <br />CCR 2712 i <br />Monitoring Ian is onsite. <br />7 <br />8 <br />CCR 2712 b <br />CCR 2643 d <br />Maintenance & monitoring records <br />Daily monitoring of suction piping (pre -January, 1, 1984 <br />M1) <br />9 <br />HSC 25292.1 <br />UST system isoperated to prevent unauthorized release <br />10 <br />11 <br />CCR 2632 (c)(2) <br />CCR 2630 d <br />UST monitoring system is present (M1) <br />UST system monitoring equipment is properly located to detect a leak M1 <br />12 <br />13 <br />HSC 25291 b <br />CCR 2636 (f)(1) <br />UST system monitoring equipment is operational (M1) <br />Continuous monitorings stem for underground piping & UDC is present M1 <br />14 <br />15 <br />CCR 2631 a <br />HSC 25291 (a)(2) <br />Primary containment is product tight <br />Secondary containment for UST is tight <br />16 <br />CCR 2636 (c)(1) <br />All releases in secondary pipingflow to a collection sum <br />17 <br />HSC 25291 <br />Line leak detectors are installed <br />(M1 <br />18 <br />19 <br />CCR 2635 (b)(1) <br />CCR 2635 (b)(2) <br />Spill container <br />Overfill prevention system <br />(M2) <br />M2 <br />20 <br />21 <br />CCR 2636 (a) <br />HSC 25291 (e) <br />Conventional suction piping shall have continuous monitoring & <br />Water in 20 containment analyzed & properly disposed of <br />20 containment <br />22 <br />CCR 2650 <br />Recording/reporting of unauthorized releases <br />M1 <br />23 <br />CCR 2715 <br />Designated Operator: a Statement from UST owner-, c -e <br />nthly inspection; Employee training <br />24 <br />1 CCR 2638 a <br />Annual monitoring certification <br />X <br />25 <br />CCR 2638 a <br />Annual line leak detector test <br />M1 40 <br />26 <br />27 <br />HSC 25284.2 <br />CCR 2636 4 <br />Annuals ill containment testin <br />Annual line tightness test <br />M1 <br />28 <br />29 <br />CCR 2661 <br />CCR 2643 a <br />Repair for tank/piping has had tightness test <br />Biennial tightness test of gravity piping(pre-January 1, 1984 <br />(M2) <br />30 <br />CCR 2643 d <br />Triennial line test for conventional suction piping (pre -January 1, <br />1984) (M1) <br />31 <br />HSC 25292.5 <br />Double walls stem located within 1000' of public well-ELD <br />32 <br />CCR 2661 <br />Permit to repair UST system <br />33 <br />HSC 25286 a <br />Permit to alter monitoring system <br />34 <br />HSC 25298 b <br />Permit to temporarily close UST system <br />35 <br />HSC 25298 c <br />Permit to close UST system <br />36 <br />HSC 25299 <br />a 9 2 <br />Disabling leak detection devices <br />37 <br />HSC 25298 a <br />Ille al abandonment of UST system <br />38 <br />Other: <br />EHD INSPECT0 <br />/J( <br />PHONE• <br />2 0 .— 0 <br />UIC <br />Septic system: <br />❑ Serves >_20 people/day <br />❑ Receives other than sanitary waste <br />Other disposal methods: <br />❑ Dry wells/French Drains <br />RECEIVED BY: <br />TITLE: <br />m� , /OL <br />/` ' / <br />EHD 23-02-002 REV 8/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.