My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0080495 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
3566
>
2600 - Land Use Program
>
SR0080495 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:58 AM
Creation date
11/7/2019 9:46:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0080495
PE
2602
FACILITY_NAME
SINGH / KAUR TRUCKING FACILITY
STREET_NUMBER
3566
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95304
APN
23906018
ENTERED_DATE
4/16/2019 12:00:00 AM
SITE_LOCATION
3566 W ELEVENTH ST
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br /> percolation test must demonstrate a satisfactory percolation rate within the proposed <br /> septic system disposal field. <br /> Details and results of the percolation testing are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1, <br /> 4/12/2019 3.36 11.9 4 hr. Satisfactory perc. <br /> Shallow Test rate <br /> Note: A satisfactory percolation rate for a "shallow"test is less than or equal to 60 minutes per inch. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 5.0 and 30.0 min/in requires an <br /> eight-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils within the proposed sewage disposal area of the Site have demonstrated a <br /> satisfactory percolation rate for the use of a standard septic system in accordance with <br /> the requirements of the San Joaquin County Environmental Health Department. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines or a filter bed should follow the San <br /> Joaquin County On-Site Wastewater Treatment Systems Standards (2017) where <br /> applicable. <br /> LOGE 1843 Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.