Laserfiche WebLink
d`0_� <br /> Table 5. Result of Nitrate Loading Calculation <br /> Variable Value Units Description <br /> Nc 1.6 mg/L-N Long-term average concentration of percolating effluent <br /> The US EPA recommended MCL for nitrate in drinking water is 10 mg/L-N. In a worst- <br /> case situation, the maximum buildup of nitrates in the aquifer from the use of septic <br /> systems on the Site is predicted to be 1.6 mg/L-N. The result of the nitrate loading <br /> estimate is well below the maximum drinking water standard. <br /> Discussion of Nitrate Loading Results <br /> Total Nitrate Impact <br /> Based on the method and assumptions described, the result of the nitrate loading <br /> estimate indicates that the existing and proposed development on the Site should not <br /> cause a buildup of nitrates in the aquifer above 10 mg/L-N. Because of the satisfactory <br /> result, no nitrate mitigation measures are recommended. <br /> LOGE 1912 Page 14 <br />