My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0080613
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MELTON
>
7670
>
2600 - Land Use Program
>
SR0080613
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2019 3:11:42 PM
Creation date
11/8/2019 2:03:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SR0080613
PE
2602
FACILITY_NAME
NG PROPERTY
STREET_NUMBER
7670
Direction
E
STREET_NAME
MELTON
STREET_TYPE
RD
City
MANTECA
Zip
95337
APN
25722037
ENTERED_DATE
5/13/2019 12:00:00 AM
SITE_LOCATION
7670 E MELTON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br /> percolation test must demonstrate a satisfactory percolation rate within the proposed <br /> septic system disposal field. Details and results of the percolation test are summarized <br /> in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1, <br /> 5/1/2019 3.10 4.6 4 hr. Satisfacto� perc. <br /> Shallow Test rate <br /> Note: A satisfactory percolation rate for a "shallow" test is greater than 1 but less than or equal to 60 minutes per <br /> inch. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 1.0 and 5.0 min/in requires a <br /> 20-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils within the proposed sewage disposal area of the Site have demonstrated a <br /> satisfactory percolation rate for the use of a septic system in accordance with the <br /> requirements of the San Joaquin County Environmental Health Department. <br /> Because of the percolation rate between 1.0 and 5.0 min/in encountered in the test <br /> hole, the San Joaquin County Environmental Health Department will require a 20-foot <br /> separation from the bottom of the dispersal system to ground water, or mitigation by <br /> system design or enhancement (see Table 2). Ground water is anticipated to be <br /> encountered approximately 13 to 16 feet below ground surface at the Site. TheSan <br /> Joaquin County Environmental Health Department may require a shallow/modified <br /> septic system to mitigate the shallow depth to water. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines or a filter bed should follow the San <br /> Joaquin County On-Site Wastewater Treatment Systems Standards (2017) where <br /> applicable. <br /> LOGE 1914 Page 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.